| 3 Phase Power Analyzer |
| Model TES-3600 |
| FEATURES |
|
| DISPLAYS 10 POWER METERS AT THE SAME TIME |
![]() |
| PC SOFTWARE |
![]() |
| HARMONIC ANALYSIS |
![]() |
| POWER MEASUREMENT | ||
| Active Power Measurement (KW) | ||
|
Range |
Accuracy |
Effect of power
factor |
| 600.0KW |
±0.5rdg, ±10dgts
+ clamp on sensor specification |
±0.1% rdg |
| Reactive Power Measurement (KVAR) | ||
|
Range |
Accuracy |
Effect of power
factor |
| 600.0KVAR |
±0.5rdg, ±10dgts
+ clamp on sensor specification |
±0.1% rdg |
| Apparent Power Measurement (KVA) | |
|
Range |
Accuracy |
| 600.0KVA |
±0.5rdg, ±10dgts
+ clamp on sensor specification |
| Power Factor Measurement | ||
|
Range |
Accuracy |
Polarity Display |
| -1.000 (lead to 0.000
to +1.000 (lag) |
±1dgt for each
calculation from measured values |
When the current lags
the voltage unsigned; when the current leads the voltage: "-" |
| Power Integration Measurement | ||
|
Power Integration |
Resolution |
Accuracy |
| 0.0KWh to 9999MWh |
0.1KWh |
±0.5rdg, ±10dgts
+ clamp on sensor specification |
| 0.0Kvarh to 9999Kvarh |
0.1Kvarh |
|
| 0.0KVAh to 9999KVAh |
0.1KVAh |
|
| DATALOGGING CAPACITY (512KB memory, 20 000 readings) |
| Auto data logger (20 000 sets data) function can be settin the start/stop and interval time, use the store data download to PC for further power analyzer to V, I, P, Q, S, PF, KW, KVAR and KVA time varying graph and maximum, minimum, average value with elapsed time. |
| CARRYING CASE PACKAGE |
![]() |
| ELECTRICAL SPECIFICATIONS |
| Voltage Measurement (V) |
|
Range |
Method |
Accuracy |
Input impedance |
| 600.0V |
True RMS |
±0.5% ±10dgts (>30V) |
2M |
| Current Measurement (A) | ||
|
Range |
Method |
Accuracy |
| 250A; 500A; 1000A |
True RMS |
±0.5%rdg ±10dgts
+ clamp on sensor specification |
| Active Power Measurement (KW) | ||
|
Range |
Accuracy |
Effect of power factor |
|
600.0 KW |
±0.5%rdg ±10dgts +
clamp on sensor specification |
±0.1%rdg |
| Reactive Power Measurement (KVAR) | ||
|
Range |
Accuracy |
Effect of power factor |
|
600.0 KVAR |
±0.5%rdg ±10dgts +
clamp on sensor specification |
±0.1%rdg |
| Apparent Power Measurement (KVA) | |
|
Range |
Accuracy |
| 600.0 KVA |
±0.5%rdg ±10dgts
+ clamp on sensor specification |
| Power Integration Measurement | ||
|
Power Integration |
Resolution |
Accuracy |
| 0.0KWh to 9999MWh |
0.1KWh |
±0.5rdg, ±10dgts
+ clamp on sensor specification |
| 0.0Kvarh to 9999Kvarh |
0.1Kvarh |
|
| 0.0KVAh to 9999KVAh |
0.1KVAh |
|
| Power Factor Measurement | ||
|
Range |
Accuracy |
Polarity Display |
| -1.000 (lead) to 0.000
to +1.000 (lag) |
±1dgt for each
calculation from measured values |
When the current lags
the voltage unsigned; when the current leads the voltage: "-" |
| Frequency Measurement | ||
|
Range |
Measurement Source |
Accuracy |
| 600.0 KVAR |
Voltage U1 |
±0.5%rdg ±1dgt |
| GENERAL SPECIFICATIONS | |
| Size (LxWxH) | 235 x 116 x 55 mm (9.3 x 4.6 x 2.1 in.) |
| Operating Temp. and Humidity | 0 to 50°C (32 to 122°F) R.H. <80% non-condensing |
| Storage Temp. and Humidity | -10 to 60°C (14 to 140°F) R.H <70% non-condensing |
| Accessories |
|
| CAT. NO. | DESCRIPTION |
| MTP3600-00 | 3 Phase Power Analyzer |