GENEQ > Biotechnology > pH Meters & Conductivity Meters
GENEQ > Environment > pH Meters & Conductivity Meters

Orion 4-Star Benchtop pH/Conductivity Meter
 


Benchtop Meter (Cat. No. 1117000)
Benchtop Meter Kit (Cat. No. 1117001)
• Easy-to-use meter provides reliable, accurate pH, conductivity, resistivity, salinity, TDS and temperature measurements for soil and water analysis applications.
• SMART STABILITY™ and SMART AVERAGING™ functions for automatically optimized accuracy, precision and response time
• Storage of up to 10 password protected methods for easy retrieval of operation procedures
• Accepts ISFET (Ion Selective Field Effect Transistor) electrodes
• Convenient, built-in Quick-Start Guide
• Meets all U.S. Pharmacopeia (USP) requirements
• Simultaneous display of pH, Conductivity and temperature measurements
• Auto stirrer control

Specifications
pH
Readout Range / Resolution -2.000 to 19.999 or 0 to 14 in aqueous solutions / 0.1,0.01,0.001
Relative Accuracy ± 0.002
SMART STABILITY™ and SMART AVERAGING™ Resolution dependent / automatic
AUTO-CAL™ and/or Manual Calibration 1 to 5 points; US/NIST, DIN, and custom buffers recognized
mV
Range – mV / RmV ± 1999.9
ORP EH autocalibration to standard hydrogen electrode
Resolution 0.1
Relative Accuracy ± 0.2 mV or 0.05%, whichever is greater
Conductivity
Range 0.000 to 3000 mS/cm, auto resolution with cell constant dependence
Resolution 4 signi•cant digits down to 0.001 µS/cm, cell constant dependent
Relative Accuracy 0.5% ± 1 digit or 0.01 µS/cm, whichever is greater
Cell Constant 0.001 to 199.9
Cell Compatibility 2 Cell, 4 Cell, Planar Cell
SMART STABILITY™ and SMART AVERAGING™ Resolution dependent / automatic
DirectCal™ / AUTO-CAL™ 1 to 5 points / 1 to 3 points
Resistivity
Range / Resolution 0.0001 to 100 Megohm / Auto resolution
Relative Accuracy 0.5 % ± 1 digit
Salinity
Range / Resolution 0.01 to 80.0 ppt NaCl equivalent, 0.01 to 42ppt practical salinity / 0.01
Relative Accuracy ± 0.1 ± 1 digit
TDS
Range / Resolution 0 to 19999 / 1 mg/L
Relative Accuracy ± 0.5 % ± 1 digit
Adjustable TDS Factor 0.00 to 10.00
Temperature
Range / Resolution -5 to 105 °C / 0.1 up to 99.9 °C, 1.0 over 99.9 °C
Relative Accuracy ± 0.1 °C
Temperature Compensation Cond (nLF, linear 0.0 to 10.0% / °C); pH (auto/manual)
Display Custom backlit LCD, for easy viewing
Inputs/Outputs
Sensor Inputs Conductivity-miniDIN - Locking; ATC-miniDIN-Locking; pH - BNC; Reference-Pin tip; Stirrer-Phono-jack
Solid State pH Sensor ISFET
Communications Bi-directional RS232 - Stereo jack, optional USB interface Cable
Special GLP Software Features
# Of Data Logging Points 200 points by time, stability or manual read with time/date stamp
Calibration Log Last 10 Calibrations
User Method Storage 10 Saved
Advanced Self-test and Diagnostics YES
GLP Electrode Veri•cation YES
Password Protection YES
Internet Software Updates / Downloadable Methods YES
21 CFR Part 11 Software Package Optional
Power Universal power adapter and battery power 4 x AA batteries
Regulatory and Safety CE, CSA, UL, TÜV, FCC Class A limits
Environmental Operating Conditions
Ambient Operating Temperature 5 to 45 °C
Relative Humidity 5 to 85% Non-Condensing
IP Rating IP54, splashproof and dustproof
Warranty 36 months (from date of purchase)
   
Above data generated under optimal/controlled circumstances.

pH/Conductivity Benchtop Meter Kit (1117001) Includes:
Cat. No.
Description
1117000
4-Star pH/Conductivity benchtop meter
9157BNMD
Triode™, pH/ATC combination electrode
013005MD
Conductivity cell, 1.5m cable
011007
Conductivity/TDS standard 1413 µS/cm, 5x60 mL
910001
pH electrode storage solution, 475 mL
910104
pH 4.01 buffer, 475 mL
910107
pH 7.00 buffer, 475 mL
910110
pH 10.01 buffer, 475 mL