Orion 4-Star Benchtop pH/ISE Meter
![]() |
Benchtop Meter (Cat. No. 1115000)
Benchtop Meter Kit (Cat. No. 1115001)
Easy to use, 3-button function
SMART STABILITY and SMART AVERAGING functions for automatically
optimized accuracy, precision and response time
Storage of up to 10 password protected methods for easy retrieval
of operation procedures
Accepts ISFET (Ion Selective Field Effect Transistor) electrodes
Simultaneous display of pH or ISE and temperature measurements
Auto stirrer control
| Specifications | |
| pH | |
| Readout Range / Resolution |
-2.000 to 19.999 or 0 to 14 in aqueous solutions / 0.1,0.01,0.001 |
| Relative Accuracy |
± 0.002 |
| SMART STABILITY and SMART AVERAGING |
Resolution dependent / automatic |
| AUTO-CAL and/or Manual Calibration | 1 to 5 points; US/NIST, DIN, and custom buffers recognized |
| ISE | |
| Range / Resolution |
0 to 19900 / 1,2, or 3 signicant digits |
| Relative Accuracy |
± 0.2 mV or 0.05%, whichever is greater |
| SMART STABILITY and SMART AVERAGING |
Resolution dependent / automatic |
| Units |
M, mg/L, %, ppb, or no units |
| # ISE Cal points |
1 to 5 |
| Special ISE Calibration Features | Linear point to point, selectable auto-blank non-linear, low concentration range |
| mV | |
| Range mV / RmV |
± 1999.9 |
| ORP |
EH autocalibration to standard hydrogen electrode |
| Resolution |
0.1 |
| Relative Accuracy | ± 0.2 mV or 0.05%, whichever is greater |
| Temperature | |
| Range / Resolution |
-5 to 105 °C / 0.1 up to 99.9 °C, 1.0 over 99.9 °C |
| Relative Accuracy |
± 0.1 °C |
| Temperature Compensation |
Auto/Manual |
| Display | Custom backlit LCD, for easy viewing |
| Inputs/Outputs | |
| Sensor Inputs |
pH/ISE - BNC; ATC-miniDIN-Locking; Reference-Pin tip; Stirrer-Phono-jack |
| Solid State pH Sensor |
ISFET - miniDIN - locking |
| Communications | Bi-directional RS232 - Stereo jack, optional USB interface Cable |
| Special GLP Software Features | |
| # Of Data Logging Points |
200 points by time, stability or manual read with time/date stamp |
| Calibration Log |
Last 10 Calibrations |
| User Method Storage |
10 Saved |
| Advanced Self-test and Diagnostics |
YES |
| GLP Electrode Verification |
YES |
| Password Protection |
YES |
| Internet Software Updates / Downloadable
Methods |
YES |
| 21 CFR Part 11 Software Package |
Optional |
| Power |
Universal power adapter and battery power 4 x AA batteries |
| Regulatory and Safety | CE, CSA, UL, TÜV, FCC Class A limits |
| Environmental Operating Conditions | |
| Ambient Operating Temperature |
5 to 45 °C |
| Relative Humidity |
5 to 85% Non-Condensing |
| IP Rating |
IP54, splashproof and dustproof |
| Warranty | 36 months (from date of purchase) |
| Above data generated under optimal/controlled circumstances. | |
| Note: ISFET capability available in Fall 2005 | |
| pH/ISE Benchtop Meter Kit (1115001) Includes: | |
| Cat. No. |
Description |
| 1115000 |
4-Star pH/ISE benchtop meter |
| 8102BNU |
ROSS Ultra® glass pH electrode |
| 917005 |
A series meter epoxy ATC probe |
| 810001 |
ROSS pH electrode storage solution, 475 mL |
| 1110001 |
Electrode stand |
| 910104 |
pH 4.01 buffer, 475 mL |
| 910107 |
pH 7.00 buffer, 475 mL |