| Specifications HI 991300 |
| Range | |
| pH | 0.00 to 14.00 pH |
| EC | 0 to 3999 μS/cm |
| TDS | 0 to 2000 ppm (mg/L) |
| Temperature | 0.0 to 60.0°C (32.0 to 140.0°F) |
| Resolution | |
| pH | 0.01 pH |
| EC | 1 μS/cm |
| TDS | 1 ppm |
| Temperature | 0.1°C (0.1°F) |
| Accuracy (@20°C/68°F) | |
| pH | ±0.01 pH |
| EC | ±2% F.S. |
| TDS | ±2% F.S. |
| Temperature | ±0.5°C (±1.0°F) |
| TDS Conversion Factor | selectable 0.45 to 1.00 with 0.01 increments (default 0.50) |
| pH Calibration | automatic at 1 or 2 points with 2 sets of memorized standard buffers (pH 4.01/7.01/10.01 or pH 4.01/6.86/9.18) |
| EC/TDS Calibration | automatic, 1 point at 1382 ppm (CONV 0.5) or at 1500 ppm (CONV 0.7) or at 1413 μS/cm (others) |
| Temperature pH | automatic |
| Compensation EC/TDS | automatic with selectable β from 0.0 to 2.4%/°C with 0.1 increments |
| Probe | HI 1288, pH/EC/TDS/T, DIN connector, 1 m (3.3’) cable (included) |
| Battery type / Life | 4 x 1.5V AAA / approximately 500 hours of continuous use |
| Environment | 0 to 50°C (32 to 122°F); RH max 100% |
| Dimensions / Weight | 150 x 80 x 36 mm (5.9 x 3.1 x 1.4”) / 210g (7.4 oz.) |
| Specifications HI 991301 |
| Range | |
| pH | 0.00 to 14.00 pH |
| EC | 0.00 to 20.00 mS/cm |
| TDS | 0.00 to 10.00 ppt (g/L) |
| Temperature | 0.0 to 60.0°C (32.0 to 140.0°F) |
| Resolution | |
| pH | 0.01 pH |
| EC | 0.01 mS/cm |
| TDS | 0.01 ppt |
| Temperature | 0.1°C (0.1°F) |
| Accuracy (@20°C/68°F) | |
| pH | ±0.01 pH |
| EC | ±2% F.S. |
| TDS | ±2% F.S. |
| Temperature | ±0.5°C (±1.0°F) |
| TDS Conversion Factor | selectable 0.45 to 1.00 with 0.01 increments (default 0.50) |
| pH Calibration | automatic at 1 or 2 points with 2 sets of memorized standard buffers (pH 4.01/7.01/10.01 or pH 4.01/6.86/9.18) |
| EC/TDS Calibration | automatic, 1 point at 6.44 ppt (CONV 0.5) or at 9.02 ppt (CONV 0.7) or at 12880 μS/cm (others) |
| Temperature pH | automatic |
| Compensation EC/TDS | automatic with selectable β from 0.0 to 2.4%/°C with 0.1 increments |
| Probe | HI 1288, pH/EC/TDS/T, DIN connector, 1 m (3.3’) cable (included) |
| Battery type / Life | 4 x 1.5V AAA / approximately 500 hours of continuous use |
| Environment | 0 to 50°C (32 to 122°F); RH max 100% |
| Dimensions / Weight | 150 x 80 x 36 mm (5.9 x 3.1 x 1.4”) / 210g (7.4 oz.) |