The HI 9126 is the next generation in professional,
accurate, easy-to-use pH meters. Designed to provide
laboratory results in a sleek, portable design. The HI 9126
features HANNA‘s exclusive Calibration Check™ technology. Calibration Check™ monitors the pH bulb
and reference junction of the electrode every time the
instrument is calibrated. In the event of a dirty pH bulb,
Calibration Check™ prompts the user that additional
cleaning may be needed.
The extended multi-level LCD displays pH and temperature
(°C or °F) readings simultaneously, while also
displaying the electrode status and operational guides.
The HI 9126 helps users through the calibration process
with clear on-screen messages. The meter features a
series of diagnostic features to improve measurement
consistency and reliability.
Calibration is performed automatically at 1 or 2 points
with 7 standard buffers and 2 custom buffers.
HI 9126 is supplied with rechargeable batteries and a
inductive docking station for easy recharging.
The meter is provided with the BEPS (Battery Error
Prevention System) which automatically turns the
instrument off when the battery level is too low to
ensure reliable readings.
The HI 9126 can also be used for ORP measurements in
the mV range with 0.1 mV resolution. |
- Exclusive Calibration Check™ (HI 9126)
- Electrode condition monitoring (HI 9126)
- Backlit LCD (HI 9126)
- Multi-level display
- On-screen operational guide
- Extended pH and temperature ranges
- Up to 7 standard buffers for calibration and 2 custom buffers
- User-selectable calibration timeout reminder
- Measures in °C or °F
- Waterproof
- Rechargeable batteries
- Inductive battery recharger docking station included
- BEPS (Battery Error Prevention System)
- pH electrode, temperature probe and hard carrying case included
|
| Cat. No. |
Description |
| HI 9126, HI 9125 and HI 9124 are supplied with
HI 1230B combination double-junction, gel-filled
pH electrode, HI 7662 stainless steel temperature
probe with 1 m (3.3’’) cable, pH 4.01 & pH 7.01
buffer solutions (20 mL sachets), 100 mL plastic
beaker, (4) 1.2 AAA rechargeable batteries (inside
the instrument), HI 710044 inductive recharger*
with power adapter, instruction manual and
rugged carrying case. |
| *HI 9126-01 (115V), HI 9126-02 (230V), HI 9125-01 (115V), HI 9125-02 (230V), HI 9124-01 (115V), HI 9124-02 (230V) |
| Electrodes |
| HI 1230B |
pH electrode, double junction,
PEI body, BNC connector,
1 m (3.3’) cable |
| HI 3230B |
ORP electrode, gel filled, PEI
body, with platinum sensor, BNC
connector, 1 m (3.3’) cable |
| HI 7662 |
Temperature probe |
| Solutions |
| HI 7004L |
pH 4.01 buffer solution, 500 mL |
| HI 7007L |
pH 7.01 buffer solution, 500 mL |
| HI 7010L |
pH 10.01 buffer solution, 500 mL |
| HI 70004P |
pH 4.01 buffer solution, 20 mL
sachets (25) |
| HI 70007P |
pH 7.01 buffer solution, 20 mL
sachets (25) |
| HI 70010P |
pH 10.01 buffer solution, 20 mL
sachets (25) |
| HI 70300L |
Electrode storage solution, 500 mL |
| HI 7061L |
Electrode cleaning solution, 500 mL |
| Accessories |
| HI 76405 |
Electrode holder |