GENEQ
> Biotechnology > Refractometers
Abbe Refractometer
Model DR-M
| EASY TO USE |
| Operation consists of placing a sample on the prism; inserting an interference filter in the light source; while looking through the eyepiece, the control knob is turned until the shadowline is centered in the crosshairs (see image below left); the reading is shown on the large LCD display. Units calibrate with water (Model DE-M2) or the included glass standard. |
| PROFESSIONAL FEATURES |
| Large, menu-driven LCD display; primary & secondary prisms; color compensator dial; large measurement dial; focusable eyepiece; desiccant case; drain nozzle. |
| MULTIPLE WAVELENGTHS |
| Measures at 589nm (D) or 546nm (E) with the two included interference filters. Capable of measuring in the range of 450-1100nm with the use of optional interference filters. For testing above 680nm, the optional Infrared Viewer (cat. no. RE-9115) is required. External halogen light source features digital readout, variable intensity, and adjustable positioning of the light guide. |
| ABBE NUMBER MEASUREMENT |
| Automatic, digital readout of Abbe Number (vD & vE) in 4 easy steps. For vD, the included 589nm interference filter and the optional 486nm (cat. no. RE-3521) & 656nm (cat. no. RE-3522) interference filters are used. For vE, the included 546nm interference filter and the optional 480nm (cat. no. RE-3524) & 644nm (cat. no. RE-3525 interference filters are used. |
| DIGITAL ACCURACY |
| High resolution and accuracy provides substantial precision for both liquid and solids testing. The digital display and sample operation both enhance overall precision - no analog scales to read. |
| PRISM TEMP. CONTROL |
| Featuring 2 circulator nozzles for the primary prism and 2 for the secondary prism, the DR-M Series models can be connected to a circulating bath to accuracy regulate prism temperature. The prism temperature is displayed on the LCD display. The effective temperature range is 5-50°C. |
| GLASS, PLASTIC, 7 FILM TESTING |
| Transparent or translucent glass and plastic samples can be measured with the use of the included contact liquid. Transparent or translucent film samples can be measured with the use of the included contact liquid and lighting glass. |
| Note: The refractive index (nD) of the sample must be lower than that of the contact liquid. The included bromonaphthalene contact liquid has a refractive index (nD) value of 1.6300; the included methylene iodide solution (Model DR-M4 only) has a refractive index (nD) value of 1.7400. |
| DOUBLE REFRACTION (BIREFRINGENCE) TESTING |
| With the optional polarizing eyepiece (cat. no. RE-1145), the DR-M Series models can test samples exhibiting double refraction. For example, a piece of film with this caracteristic would have a machining direction (Y axis), right-angle to machining direction (X axis), and a thinkness direction (Z axis) -- the refractive index must be measured for each axis. |
| DR-M SERIES SPECIFICATIONS | |
| Measuring System | Optical Refraction Critical Angle Detection |
| Measuring Range | Refractive Index (model
DR-M2)
|
Refractive Index (Model
DR-M4)
|
|
| Resolution | Refractive Index: 0.0001 |
| Accuracy | Refractive Index: ±0.0002 |
| Wavelength Range | 450-1100nm (w/Interference Filters) |
| Infrared Viewer (Optional) | Required for 681-1100nm |
| Abbe Number | vD & vE (w/Optional
Interference Filters) 0.1 Resolution |
| Interference Filters (Included) | 589nm (D) & 546nm (E) |
| Interference Filters (Optional) | 486nm (F) & 656nm (C)
[Required for Abbe Number vD] 480nm (F') & 644nm (C') [Required for Abbe Number vE] 450-1100nm [Curtom Wavelengths] |
| Ambient Temperature | 5-40°C |
| Measuring Temperature | 5.0-50.0°C |
| Sample Quantity | >0.1ml |
| Relative Humidity | <90% |
| Altitude | <5000m Above Sea Level |
| Calibration Liquid / Medium | Distilled Water [Model
DR-M2] Glass Standard, 1.5163 nD (w/Contact Liquid) [Model DR-M2] Glass Standard, 1.6200 nD (w/Contact Liquid) [Model DR-M4] |
| Display | LCD |
| Measuring Light Source | Halogen Lamp |
| Prism | Optical Glass |
| Prism Housing | SUS316 Stainless Steel |
| Circulator Nozzles | 2 for primary Prism, 2 for Secondary Prism |
| Desiccant Case | Tablets w/ Color Indicator |
| Power Supply | 100 to 240V AC, 50/60 Hz |
| Power Consumption | 100V A |
| Printer Output | Centronics (Parallel) |
| Dimensions | 29(L)x13(W)x31(H) cm [Main
Unit] 33(L)x15(W)x11(H) cm [Light Source] |
| Weight | 6.0kg [Main Unit] 3.0kg [Light Source] |