GENEQ > Environment > Air samplers
| Volumetric Flow Controlled (VFC) Air Sampler |
| model TE-5170DV |
Volumetric Flow Controlled Total Suspended
Particulate TSP High Volume Air Sampling System. Includes anodized aluminum
shelter, 8" x 10" stainless steel filter holder with stagnation
pressure tap, blower motor assembly, continuous/flow pressure recorder,
30" manometer, volumetric flow controller with look up table, digital
timer and digital elapsed time indicator. 110v/60 hz or 220 v/50hz |
| Specifications: | |
| Inlet collection efficiency: | Meets EPA Code of Federal Regulation Appendix B to Part 50 |
| Flow rate: | 42 cfm – 45 continuous |
| Filter media: | Glass Fiber Filter 8" x 10" (TE-G653) |
| Flow control: | Volumetric flow controller (TE-10557TSP) |
| Motor blower: | 2-stage vacuum 1.0 HP 110v/60hz (TE-115923) 220v/50hz (TE-116111) |
| Water Manometer | 30" water manometer (TE-5030) |
| Timer: | Digital timer programmer with digital elapsed time indicator (TE-302) Sample delay 0-11 days |
| Shipping Information: | |
| Size: 45.5" x 22.5" x 20"/50lbs, 28 " x 21 " x 20"/30 lbs | |
| Assembled Space Requirement: | 24" square x 53" high |
| Power Requirement | Single phase with earth ground, 110v/60hz or 220v/50hz |
| Motor Specifications: | 110v/60hz – Part #TE-115923 double ball bearing thru-flow discharge 220v/50hz – Part #TE-11611 ball/sleeve bearing, thru-flow discharge. |
| Altitude Application: | to 10,000 feet above sea level |
| Ambient Temperature Application: | -30 to + 50ºC |
| Relative Humidity Application: | 0 - 100% |
| Sample Delay Start Range: | 0 - 11 days |
| Start up amps: | 20 amps |
| Running amps: | 8 amps |