Biolog Ambulatory Data Recorders

The Biolog(R) is a rugged, yet flexible, ambulatory physiological data recorder supporting a broad line of signal conditioners from a number of channels. Three easily customized platforms are available to fit most physiological research recording needs. The 3992 is pictured to the left. Conditioned data are sampled at the desired resolution (8, 12, or 16 bits) under microprocessor control. Recorded data is compactly stored on a PCMCIA memory card (3992 and 3993 only).

When recording is complete, the card is removed from the Biolog and inserted into a card reader (BCR-100, see below), connected to the host PC through a serial port. The Downloading and Plotting Software (DPS) operating on a PC host computer (win31/9x) supervises downloading the tightly packed data to a disk file. From there it can be viewed, printed, moved to the clipboard, or converted into channel specific ASCII data files (for further spreadsheet analysis) all under DPS control.

FEATURES (Common 399x Biolog)
  • A wide range of signal conditioners are available
  • ECG/HR/IBI, EOG(D.C.!), EMG, EGG, EEG and more
  • Fetrodes(R) used on all bioelectric channels
  • Respiration, PPG/PTT, Pressure, Temperature and others
  • Proprietary front-ends: SCL, Impedance Respiration
  • All input assemblies / transducers included
  • Rugged keyed and locking input connectors
  • Each signal conditioner designed to YOUR specifications for Gain, Frequency Response, Data Reduction, Sample Rate, etc.
  • 9V battery operation yields inherent subject isolation
  • Flexible PCMCIA "ram card" data storage (3992 and 3993)
  • SRam cards hold up to 4 MB of data (2 MB standard)
  • Ram cards can be swapped quickly for long-term recording
  • Download through Biolog Card Reader

3991 Platform

  • 1, 2, or 3 channels of signal conditioning
  • Sample resolution: 8 or 12 bits
  • Recording capacity: 64 KBytes built-in (typical)
  • Plastic case size: 1.75" x 3.5" x 5.5" (typical)
  • One event mark / control button
  • Setup for recording by software
  • Data downloaded through serial link to PC

3992 Platform
  • 1 to 7 channels of signal conditioning
  • Sample resolution: 8 or 12 bits
  • Rugged, plastic case: 1.5" x 5" x 7"
  • 12 key keypad with tactile and visual feedback
  • Built-in "graphics" LCD waveform display
  • Interlocking power switch to prevent ram card removal or insertion while power is applied
  • Ram card data downloaded through BCR

3993 Platform
  • 1 to 14 channels of signal conditioning
  • Sample resolution: 8, 12, or 16 bits
  • 1 or 2 batteries with automatic level sense and switching
  • 1 or 2 Ram Cards with automatic cross-over
  • Rugged, powdercoated aluminum case: 2.75" x 6" x 8"
  • 12 key keypad with tactile and visual feedback
  • Built-in "graphics" LCD waveform display (not shown)
  • Ram card downloaded through BCR