| Liquid flow measurement unit |
| Model BMD 150 |
| Applications |
| Demonstrations of different principles of flow measurement. Manipulation methods
|
| Specifications |
| 1. Multicellular pump 2 m3/h Single phase 230 VAC 2. Diaphragm valve 3. Rotameter Glass tube – stainless steel floater 316 L Linear scale 0-1053 L/h 4. Electromagnetic flow meter Surface PFA, electrodes in stainless steel Accuracy : ± 0.5% of the measured value Signal converter : outlet 4-20 mA 5. Flow meter with axial turbine Indicator outlet PNP 12-24 VDC - 1 KΩ Scale : 0-15L/min. Accuracy : ± 0.5% of the full scale Signal converter - outlet 4-20 mA |
6. Flow meter with venturi effect Pressure inlets above and below flow meter Connected to a multimanometer 7. Nozzle valve 8. Calibrated tank 20 L Used for the calibration of the flow meters A chronometer is provided in order to measure the emptying time of the tank 9. Polypropylene tank – 75 L 10. Water filter 11. Tap Numeric indicator Programmable with microprocessor Degree of accuracy : 0.2 4 digit display |