| Capstar-100 End-Tidal CO2 Analyzer |
| Fast response end-tidal Carbon Dioxide monitor for small animals |
The CAPSTAR-100 Carbon Dioxide Analyzer
provides continuous measurement of expired CO2 over the range
0-10 percent. Its rapid response time, small sample flow requirements,
and long-term stability make it ideal for respiratory gas measurement
of rodents and larger animals. The heart of the instrument is a miniature infrared analyzer with exceptional stability, low maintenance, and a linear output. The heated measurement cell prevents water condensation. The SENSORPOD, which contains the infrared measurement cell, attaches to the front panel by a 1.5m cable. This cell can be removed for cleaning, inspection, or replacement in minutes. The digital display shows CO2 concentration in percent or mmHg, and allows breath-by-breath peak end-tidal reading or continuous rapid response. Calibration is performed with a single calibrated gas and room air. The reliability and ease of operation of the CAPSTAR-100 make it the perfect instrument for routine respiratory CO2 monitoring. It is the natural companion to our SAR-830 series Small Animal Ventilators for monitoring respiratory status. With the AVS-1 Advanced Ventilator System, it can control end-tidal CO2. It can also be used to monitor unassisted animals. Gas sampling rates of less than 30ml/min can be used, making it possible to monitor animals as small as rats. The fast response time of the CAPSTAR-100 allows end-tidal response plateaus with respiratory rates of 120 breaths/min or greater. A range of accessories is available to ensure easy setup and convenient operation. An accessory pack containing sample tubing, moisture traps, and Nafion® moisture-absorbing sample tubes is included with the instrument. |
| FEATURES |
|
| APPLICATIONS |
|
| SPECIFICATIONS | |
| Analyzer type | single beam infrared |
| Sample cell materials | sapphire and stainless steel |
| Sample inlet connector | 0.062 OD brass tube |
| Recommended sample tubing size | 0.040" - 0.062" ID Tygon |
| Measurement range | 0-10% CO2 |
| Analog output scaling | 100mV/% CO2 (0-1V) |
| Linearity | 0.1% CO2 |
| Repeatability | 0.1% CO2 |
| Response time (T10 - T90) | 100mS at 100 ml/min sampling |
| Response time (T10 - T90) | 130mS at 50 ml/min sampling |
| Response time (T10 - T90) | 250mS at 30 ml/min sampling |
| Zero stability | 0.1% (8 hours), 0.2% (24 hours) |
| Operating temperature range | 5 - 40°C |
| Optical bench temperature | 48°C, temperature controlled |
| Warm-up time | 5 min to 0.2%, 10 min to 0.1% |
| Sample rate flowmeter | 10 - 50 ml/min |
| Maximum sample cell pressure | +5 psig |
| Interference effects: vaporized anesthetic agents | negligible |
| Interference effects: 50% N2O | 0.1% at 0% CO2, 0.6% at 5% CO2 (uncompensated) |
| Nitrous oxide compensation | 0.1% at 5% CO2 (internal jumper for 25, 50, 75%) |
| Controls | Zero, Span (10-turn dials) |
| Electrical requirements | 120VAC/220VAC switchable, 35VA |
| Dimensions (main unit) | 9W x 5H x 9D in., 23W x 13H x 23D cm |
| Dimensions (SENSORPOD) | 3W x 2.5H x 3D in., 7.6W x 6.4H x 7.6D cm |
| Weight | 10 lbs (4.5kg) |