GENEQ > Material testings > Corosion
| Cyclic Corrosion Test Cabinets FOGMaster |
The FOGmaster cyclic range of Cyclic
Corrosion Test (CCT) Cabinets are designed to give complete flexibility
in the simulation of real life weathering conditions. By incorporating the versatility of Multi-environment cyclic corrosion testing these systems give the user a powerful tool in the analysis of corrosion resistance for a wide variety of sample types. With industrys demands for more stringent testing solutions the FOGmaster cyclic gives complete compliance to all major national standards including ISO, ASTM and DIN. |
| FEATURES |
|
| SPECIFICATIONS | ||
450 Litre capacity |
1000 Litre capacity |
|
| Siting Requirements | Floor standing |
Floor standing |
| Nominal Capacity | 450 Litres |
1000 Litres |
| External cabinet width | 1525mm / 60.0 |
2125mm / 83.7 |
| External cabinet depth | 900mm / 35.4 |
1200mm / 47.2 |
| External cabinet height | 1055mm / 41.5 |
1396mm / 55.0 |
| Internal cabinet width | 800mm
/ 31.5 |
1250mm
/ 49.2 |
| Internal cabinet depth | 645mm / 25.4 |
935mm / 36.8 |
| Internal cabinet height | 835mm / 32.9 |
1175mm / 46.3" |
| Salt solution reservoir capacity | 100 Litres |
100 Litres |
| Removable slotted sample racks | 6 racks each with
32 angled slots |
8 racks each with
47 angled slots |
| Cabinet Temperature Range | ambient to +60°C |
ambient to +60°C |
| Air Saturator Temperature Range | ambient to +63°C |
ambient to +63°C |
| Cabinet Humidity Range | Up to 100% RH |
Up to 100% RH |
| Salt Fog Fallout Rates | 0.5 to 3.0ml / 80cm2 /
hour |
0.5 to 3.0ml / 80cm2 /
hour |
| Approximate net weight | 180kgs / 397lbs |
395kgs / 871lbs |
![]() |
||
| SPECIFICATIONS | |
| External Service Utilities | |
| Power Requirements | Single phase 220 240VAC,
50Hz, switched electrical supply, rated to 13 Amps for 120L & 450L models,
& 16 Amps for 1000L models. NOTE: FM113 Requires three phase power supply. |
| Water | De-ionised or distilled for topping up the cabinet humidity system. Connection to a continuous de-ionised / distilled water supply pressurised to within the limits 0.5 6.0 bar (7.3 87 psi). |
| Compressed Air | A clean, dry and oil free compressed air supply, pressurised between 1.4 to 6.0 bar (20 to 87 psi). |
| Exhaust | An exhaust vent is required to an outside location to ventilate excess salt fog from the cabinet. |
| Drain | Floor level drain is required to discharge salt fog condensate. |
| NOTE: This equipment is designed for internal use only, in an environment controlled to within the following limits. | |
| Ambient Temperature | +5 to +25°C (+41 to +77°F) (no icing) |
| Ambient Humidity | 85% RH maximum (no condensation) |
| Note: The actual minimum operating temperature of the equipment will vary upon the specific ambient temperature of the environment in which it is located. | |
| CAT. NO. | DESCRIPTION |
| FMC450 | FOGmaster cyclic 450 Litre capacity |
| FMC1000 | FOGmaster cyclic 1000 Litre capacity |
| Acessories | |
| FM102 | Chart Recorder. Single pen, strip chart recorder for continuously recording the cabinet temperature. NOTE: This option is not required if FM113 is ordered |
| FM103 | Independent PT100. Provides auxiliary temperature recordings. |
| FM104 | Entry Port. 35mm (1.4) diameter, seal-able cabinet entry port. Allows connection to external monitoring equipment . |
| FM107 | Internal illumination. Illuminates the interior of the cabinet. |
| FM109 | Spares Kit. Comprises of 1 x solenoid valve, 5 x salt solution filters, 1m of peristaltic pump tube, 1 x indicator. |
| FM111 | Reinforced False Floor. For supporting large / heavy test samples. 450 Litre models only. |
| FM112 | Reinforced False Floor. For supporting large / heavy test samples. 1000 Litre models only. |
| FM113 | Controlled Humidity () Enables the humidity to be set and controlled at levels lower than 100% RH. Actual humidity levels achieved are dependant upon cabinet temperature. |
| FM114 | Chart Recorder. Two pen strip chart recorder, coupled to a temperature and humidity sensor, for continuously recording the cabinet temperature and humidity. |
| FM115 | Wall wash down facility. Required by some CCT programs for washing down the cabinet walls automatically with water, following salt spray tests. |