GENEQ > Biotechnology > Furnaces
|
|
| FEATURES |
|
| SPECIFICATIONS | ||||||||
| Model |
Controller
|
Electrical, 1Ø
|
Watts
|
Temp
|
Top Opening ID
|
Chamber Depth
|
Exterior Size
|
Ship Weight
|
|
CF56622C
|
CC58114C
|
208/240V, 50/60Hz
|
1700
|
1200°C
|
5 in.
12.7cm |
8 in.
20.3cm |
15x15x6in.
(38.1x38.1x40.6cm) |
52lbs (24kg)
|
|
CF56822C
|
CC58114C
|
208/240V, 50/60Hz
|
2600
|
1200°C
|
7.5 in.
19.05cm |
8 in.
20.3cm |
20x20x19in.
(50.8x50.8x48.3cm) |
105lbs (48kg)
|
Crucibles: These furnaces are designed for use with
a variety of crucibles including alumina, mullite, quartz and metallic.
For information on crucibles contact us.
Note: Power cord and interconnecting wiring customer supplied. Contact
us for CE Models.
Actual performance may vary depending on load, chamber size,
sample placement, ambient temperature and environmental conditions.
| CONTROLLERS | ||||||||||||||||||||||||||||||||
| 1200°C Digital, Single Setpoint Controller | ||||||||||||||||||||||||||||||||
| Control console is fully wired and includes advanced microprocessor-based digital control, a solid-state power module, on/off circuit breaker and thermocouple input jack. Includes microprocessor-based PID control (proportional, integral, derivative), single segment, single setpoint, 1 ramp to setpoint. Built-in adjustable high limit overtemperature protection. Simultaneous LED display of actual temperature vs. setpoint. May be configured to display temperature in either °C or °F. | ||||||||||||||||||||||||||||||||
| 1200°C Digital 16 Segment Programmable Controller | ||||||||||||||||||||||||||||||||
| Control console is fully wired and includes advanced microprocessor-based digital control, a solid-state power module, on/off circuit breaker and thermocouple input jack. Includes microprocessor-based PID control (proportional, integral, derivative), 1 program with 16 segments for ramp (up and down) and dwell (timed holds). Built-in adjustable high limit overtemperature protection. Simultaneous LED display of actual temperature vs. setpoint. May be configured to display temperature in either °C or °F. | ||||||||||||||||||||||||||||||||
| Option B Overtemperature Control (OTC) | ||||||||||||||||||||||||||||||||
| Adjustable digital overtemperature control, factory installed on selected control consoles with "B" designation; see chart. Protects furnace and load in the event of primary control circuit failure. Overrides main controller, assumes temperature control and shuts off power to furnace if high limit is reached. Manual re-set required for safety. Operates via magnetic contacts through signal from independent thermocouple. RS-485 communications port available as an option. | ||||||||||||||||||||||||||||||||
|