GENEQ > Environment > Conductivity Meters

TDSTestrs™ and ECTestrs™
Microprocessor-based, waterproof



These waterproof and dustproof testers offer ±1% full scale accuracy
and push-button calibration!
Waterproof, dustproof housing
Meets IP67 ratings for highest possible dustproof and waterproof protection.
Plus, there’s no need to worry if you drop your tester into water—it floats!
Replaceable electrode
you can use the same meter body over and over again, which saves you money
Push-button calibration
calibrate your tester more precisely than trimpot adjustment; no screwdrivers necessary
HOLD function
freezes reading until you can log it
Auto shut-off
turns off tester after 8.5 minutes of nonuse; saves your batteries
Four models available
TDSTestr low: 0 to 1990 ppm (10 ppm resolution)
TDSTestr high: 0 to 10.00 ppt (0.10 ppt resolution)
ECTestr low: 0 to 1990 µS (10 µS resolution)
ECTestr high: 0 to 19.90 mS (0.10 mS resolution)
Full reading displayed
no need to multiply the readout to obtain actual test values
Automatic temperature compensation (ATC)
gives you accurate readings even in fluctuating temperatures
Calibration kits available
Featuring everything you need for calibration, measurement and storage of your waterproof TDSTestr
Clockwise from near right: TDSTestr low shown actual size
•  Calibration kit includes everything you need for fast, accurate calibration
•  Calibration button tucked away in battery compartment to avoid accidental recalibration
•  Replaceable electrodes extend tester life
•  Testr carrying case stores, transports and protects your tester in the field
•  Choose from four models for conductivity or TDS measurements

APPLICATIONS

•  TDSTestr low: Use for measuring TDS in natural water. Verify reverse osmosis system operation and tap water quality. Check nutrient solution
concentration in hydroponics applications.
•  TDSTestr high: Use for measuring TDS in salt water, waste water, cooling tower water, and boiler condensate. Check nutrient solution concentration
in hydroponics applications. Measure salinity for ponds and recirculating systems. Check saline and chemical levels in pools and spas.
•  ECTestr low: Use for measuring conductivity (µS) in natural water. Verify reverse osmosis system operation and tap water quality. Check nutrient
solution concentration in hydroponics applications.
•  ECTestr high: Use for measuring conductivity (µS) in salt water, waste water, cooling tower water, and boiler condensate. Check nutrient solution
concentration in hydroponics applications. Measure salinity for ponds and recirculating systems. Check saline and chemical levels in pools and spas.
 

SPECIFICATIONS        
Model
waterproof TDSTestr low
waterproof TDSTestr high
waterproof ECTestr low
waterproof ECTestr high
Range
0 to 1990 ppm
0 to 10.00 ppt
0 to 1990 µS
0 to 19.90 mS
Resolution
10 ppm
0.10 ppt
10 µS
0.10 mS
Accuracy
±1% full-scale
Calibration
One point push-button calibration (using keys inside battery compartment)
Calibration
standard range
300 to 1990 ppm
3 to 10.00 ppt
300 to 1990 µS
3 to 19.90 mS
Operating temp.
0 to 50°C; 32 to 122°F
Temperature
compensation
Automatic (ATC), 0 to 50°C, 32 to 122°F
ATC coefficient
Beta=2% per °C, 1.11% per °F, 25°C reference temperature
Power and
battery life
Four 1.5 V alkaline batteries Eveready A76BP (supplied) 100 hrs. continuous use (approx. 600 tests per
battery pack). Alternate replacement model Eveready 357BP silver oxide, 140 hrs. continuous use.
Dimensions
Unit only: 61⁄2"L x 11⁄2" dia. (165 x 38 mm); Boxed: 71⁄4" x 23⁄4" x 17⁄8" (184 x 70 x 48 mm)
Weight
Unit only: 3.25 oz (90 g); Boxed: 6.0 oz (170 g)
Wetted materials
316 Stainless Steel (electrodes) and glass filled thermoplastic polyester

ORDERING INFORMATION  
All TDSTestrs include batteries and operating instructions.
WD-35661-11 Waterproof TDSTestr
low 0 to 1990 ppm
WD-35661-41 Waterproof ECTestr
high 0 to 19.90 mS
ACCESSORIES
WD-35661-17 Replacement electrode sensor, for all TDSTestrs and ECTestrs listed above.
WD-35624-45 Waterproof tester belt loop vinyl carrying case—holds one waterproof tester. Features separate pocket to hold calibration
solution pouches. Shpg wt 0.5 lbs (227 g)
WD-09377-16 Replacement batteries, 1.5 V, 6/pack
WD-35661-70 Deluxe TDSTestr kit. Includes 2 each calibration pouches 447 µS, 1413 µS, 2764 µS, 15,000 µS, and rinse water; sample jar;
miniature screwdriver; foam-lined plastic carrying case; and instructions. Order TDSTestr separately. Shpg wt 0.7 lb (300 g)

CALIBRATIONS SOLUTIONS
 
Conductivity-to-TDS conversion factors
Catalog Number
Calibration
solution type
ppm KCl
ppm NaCl
ppm 442
Calibration solution pouches. box of 20. Each pouch contains 20 ml of premixed calibration solution. Since the pouches are individually sealed,
the solution is guaranteed to be fresh and contaminant free every time. Accuracy ±1% at 25°C. Shpg wt 1 lb. (454 g).
WD-35653-10
447 µS
225.6
215.5
300.0
WD-35653-11
1413 µS
744.7
702.1
1000
WD-35653-12
2764 µS
1382
1414.8
2062.7
WD-35653-13
15,000 µS
8759
8532
13,455
Calibration solution bottles. 1 pint of premixed calibration solution in recyclable-PE bottle. Accuracy ±1% at 25°C. Shpg wt 1.1 lbs (510 g).
WD-00653-16
84 µS
40.38
38.04
50.50
WD-00653-47
447 µS
225.6
215.5
300.0
WD-00653-18
1413 µS
744.7
702.1
1000
WD-00653-15
1500 µS
757.1
737.1
1050
WD-00653-27
2070 µS
1045
1041
1500
WD-00653-20
2764 µS
1382
1414.8
2062.7
WD-00653-89
8974 µS
5101
4487
7608
WD-00606-10
12,880 µS
7447
7230
11,367
WD-00653-50
15,000 µS
8759
8532
13,455
For our standard waterproof TDSTestrs, request bulletin CON A3. For our + Series waterproof TDSTestrs and ECTestrs, request bulletin CON A5.