| Description |
| The Process Controller is reliable, accurate and suitable
for measuring all types of 2 and 3 wire sensors with 4- 20mA outputs including
all of Global Water’s sensors. The controller comes pre-programmed for use with 10 different sensors and 14 engineering units. In addition, the PC300 can be programmed at the factory to monitor any type of custom sensor in any units selected by the customer. The controller can also monitor sensors with voltage outputs if specified at the time of purchase. Display and Outputs The LCD display shows the type of sensor that is being monitored, the data reading and the engineering units. The display also indicates if either relay has been triggered since last reset, which relay was triggered and whether the maximum or minimum limit was exceeded. Two separate relays are provided for controlling all types of external devices including samplers, alarms, mixers, pumps, control valves, floodgates and telemetry systems. Each relay is independently programmable to trigger on maximum and/or minimum levels in one of three different modes. Installation The Process Controller has many applications and therefore many installation solutions. The case is rugged and can be easily installed in a variety of conditions. Four screw holes are provided for securing the case to a wall, panel or different types of mounting hardware. While the case is watertight and will resist moisture, Global Water does not recommended that the PC300 be mounted outdoors without providing protection from continuous exposure to the weather. |
• Digital LCD screen |
| Specifications |
| Power:
90-240 AC or 12VDC 60mA DC normal, 150mA maximum 120uA average during sleep mode |
| Enclosure: 12cm W x 20cm H x 7.5cm D, NEMA 4X |
| Sensor Reading: 5 digits + decimal point |
| Input Resolution: .005mA or 1.2mV |
| Relay Contacts: Voltage:
30VDC Current: 5A/30VDC Max Capacity: 150W Relay 1, 2nd Output: NPN to Ground, 1.0Kohm pull-up resistor Relay 2, 2nd Output: NPN to Ground, Open-collector |
| Analog Output: 4mA minimum,
20mA maximum Resolution: .005mA |
| Sensor Types/units:
Water Level (Feet/Meters), Temperature (ºF/ºC), pH (no units), Dissolved
Oxygen (%), Turbidity (NTU/ppm), Conductivity (?S), Wind Speed (MPH/KPH),
Wind Direction (º), Soil Moisture (%), Custom Sensor (any of the above, mA, mV or custom programmed units) |
| Sensor Data Range: 0.000 to 60,000 (60000 in the display with 4 different decimal point positions) |
| Relay Time Ranges: 1-60,000
seconds (16.7 hours) Resolution: 1 second increments |
| Sleep Time Range: 1-240
minutes (4 hours) Resolution: 1 minute increments |