GENEQ > Biotechnology > UV
| Crosslinkers & Translinker |
| CROSSLINKERS |
|
The crosslinkers provide an exposure instrument which utilizes
shortwave UV energy to bond DNA to a medium. Models also available with
longwave or midrange sources for laboratory and industrial applications.
Wavelength interchangeability is possible by changing the UV tube and using the corresponding UV wavelength Calibration Sensor to recalibrate the unit to the new wavelength. The Crosslinker's internal microprocessor measures and controls UV output, ensuring maximum energy efficiency. UV crosslinking takes seconds as compared to hours for oven baking. The UV crosslinking procedure optimizes the use of the ultraviolet energy while ensuring that crosslinking is consistent. |
| FEATURES |
|
Preset or user-selected UV energy exposure or UV time exposure; Presettings deliver 120,000 microjoules or five minutes of exposure |
| TRANSLINKERS |
|
The TL-2000 Translinker has all
of the features of the Crosslinker and utilizes shotwave UV in the Crosslinker
chamber. The Translinker additionally has UVP's M-20 transilliminator mounted
to the Crosslinker cabinet. On/Off controls fort he transilluminator are
included on the Crosslinker panel. The M-20 benchtopp transilluminator UV
tubes are midrange 302 nm.
Applications for Crosslinkers: Shortwave UV - UV crosslinking of DNA/RNA to membranes after Northern or Southern blot or dot blotting and colony or plaque lifts * nicking ethidium bromide stained DNA in Agarose Gels * Gene mapping for creating cleavage-inhibiting thymine dimers * Longware UV - Photochemistry * solar experimentation * UV curing * immunology research * Midrange UV - Phototherapy * UV curing * gradient sampling * UV crosslinking * solar experimentation |
| SPECIFICATIONS | |
| Crosslinker | |
| External (DxWxH) | 13.7 x 15.6 x 8.75 in. |
| Internal Chamber (DxWxH) | 12 x 10 x 5 in. |
| Weight | 15.5 lbs (7.7kg) |
| Translinker | |
| External (DxWxH) | 13.7 x 19 x 8.75 in. |
| Internal Chamber (DxWxH) | 12 x 10 x 5 in. |
| Translinker filter surface | 20 x 20 cm |
| Weight | 25 lbs (12.4 kg) |
|
ORDERING
INFORMATIONS
|
|||||
| Model |
Part. no.
115V/60Hz |
Part. no.
230V/50Hz |
Wavelength
|
Calibration sensor
|
Sensor model
|
| CL-1000 |
95-0174-01
|
95-0174-02
|
254 nm
|
97-0016-01
|
UVX-25
|
| CL-1000L |
95-0228-01
|
95-0228-02
|
365 nm
|
97-0016-02
|
UVX-36
|
| CL-1000M |
95-0230-01
|
95-0230-02
|
302 nm
|
97-0016-04
|
UVX-31
|
| TL-2000 |
95-0300-01
|
95-0300-02
|
254/302 nm
|
||
| CAT. NO. | DESCRIPTION |
| 34-0007-01 | Replacement tubes, 8 watt, 254 nm |
| 34-0042-01 | Replacement tubes, 8 watt, 302 nm |
| 34-0006-01 | Replacement tubes, 8 watt, 365 nm |