GENEQ > Environnement > Enregistreurs de données
| Enregistreur de données environnementales |
| Modèle DataLogic 3000 de Stevens |
| Description |
| The Stevens DataLogic 3000 (DL 3000) is a powerful,
fl exible, versatile and scalable data logger. Designed using the latest
technology, the DL 3000 will meet your data acquisition, processing, control
and communication requirements. |
| Features |
| • Inputs: Analog, Pulse, RS232/485, CAN Bus,
USB, Quadrature and SDI-12 |
| Applications |
| • Stand-alone &
real-time data acquisition and control • Water resources: • Water level/stage • Water flow • Water quality • Irrigation scheduling • Meteorological & Agrimet • Soil conditions • SCADA • Industrial |
| Technical Specifi cations | |
| Power Requirements | 8 - 16 VDC, <0.5mA standby current (telemetry system may require additional power) |
| Processor | 32 bit ARM and dsPIC microprocessor |
| On-Board Data Storage | FLASH storage, 4 Gigabytes |
| Recording Interval | One (1) second to 24 hours |
| Real-Time Clock | Accurate +/- 1 minute/month, leap year correction, temperature correction |
| Non-Volatile Memory | All setup parameters and clock, lithium battery backup 8 gigabytes of expandable data storage with SD card |
| Message Size | 6 - 250 bytes typically, no maximum |
| Serial Port | Four (4) RS-232, minimum +/- 5 VDC levels, 300 to 9600 baud* USB 2.0 |
| Analog to Digital | 22-bit and 16-bit resolution Input impedance: 10 K ohm (min) |
| Communications | Four (4) RS-232 (MODBUS optional) 2 front
and 2 back CAN bus USB 2.0 (fully compatible wit USB 1.0 devices) RS-485 10 Base-T Ethernet (optional) Removable SD card |
| Digital to Analog (0-5 VDC) | 12-bit resolution |
| Temperature and Humidity | Operating: -40 to 158 F (-40 to 70 C) NEMA 4 enclosure: 100% condensing Aluminum enclosure: 95% non-condensing |
| Sensor Input Selections (See expansion module for more inputs) Up to Eight (8) Analog - Single Ended and up to Four (4) Analog - Differential Ended |
Input type: 2 wire, 4 - 20 mA current
loop Sensor power: 24 VDC, 12 VDC, 5 VDC, under fi rmware control Accuracy & Resolution: 0.025% accuracy, 0.002% resolution One 22-bit analog differential isolated input: Resolution is 1 part in 4 billion |
| Pulse Count | Input type: pulse Sensor power: 5 or 12 VDC continuous Maximum rate: 120 pulses per minute |
| Serial | Input type: SDI-12 (up to 200 channels) Sensor power: 12 VDC continuous, 5 or 12 VDC under fi rmware control (switched) |
| Two Switched Excitation Voltages: | 5V, 12V and 24V |
| Physical Size (L x H x D) | Gold anodized aluminum housing 6.5 in x 4.5 in x 2.3 in (165.1 mm x 114.3 mm x 58.4 mm) |
| Optional camera input | Full support for NTSC & PAL, storage of video and images to on-board memory *115k baud for video |
| Add-ons and Accessories | |
| The Stevens DataLogic 3000 is compatible with a wide range of equipment, including accessories to expand its performance. | |
| External Display and GUI Interface | |
| User interface is facilitated by PC / PDA application programs, a computer’s non-proprietary terminal program, and/or optional touch screen display. Stevens’ GUI interface programs for the DL 3000 support multiple languages such as English, Spanish and Chinese. | ![]() |
| Expansion Modules | |
| Multiple expansion modules can be added onto the DL 3000 for additional I/O requirements. Each expansion module supports eight (8) analog inputs, one (1) isolated 22 bit A to D input, one (1) analog output, one (1) pulse, one (1) quadrature pair, SDI-12 I/O channels, and one (1) power control output. | |
![]() |
|