GENEQ > Biotechnology > Autoclaves > Sterilizers

Delta Q Sterilizers
Model Delta Q8 and Q10

DELTA Q
Your success relies on the dependable operation of key components within your operatory. Your sterilizer is one of those components. We have put the new Delta Q through rigorous testing to ensure the best, most reliable operation available. With approval for handpiece sterilization and user notification if sterilizationis interrupted, you'll feel safe in knowing you can depend on successful completion of every cycle. Excellence in engineering along with our six month replacement guarantee and three year warranty make the Delta Q a superior choice for your peace of mind.

FILTERED CLOSED DOOR DRYING
Ensures wet packs and pouches dry without compromising the sterility of instruments by airborne contaminants. The digital function display allows easy and accurate monitoring of the sterilization cycle.

ELECTRONIC TEMPERATURE AND TIME CONTROLS
Systematically monitor sterilization conditions in chamber to ensure cycle completion.

PREPROGRAMMED STERILIZATION
Preprogrammed settings save time and effort when selecting the appropriate cycle according to the type of load.

APPROVED FOR HANDPIECE STERILIZATION
Confirmation from independent testing assures that handpiece sterilization is accomplished with the Delta Q, giving the dentist and patient peace of mind.

OTHER FEATURES
  • Available in 8 and 10 in. chamber size
  • Approved for handpiece sterilization
  • Closed door filtered air drying ensures wet packs and pouches dry without compromising sterility of instruments by airborne contaminants
  • Variable timed air drying cycle saves time by giving operator the flexibility to set drying time according to load size
  • Automatic chamber perheat maximizes productivity by shortening cycle times
  • Electronic temperature and time control systematically monitor sterilization conditions in chamber to ensure cycle completion
  • One custom and four automatic preprogrammed sterilization settings allow you to select the appropriate cycle according to type of load - including a special cycle of liquids
  • Digital function display allows easy and accurate monitoring of sterilization cycle
  • Door lock opens when internal pressure is at atmospheric pressure
  • Vent valve will open and the P-2 alarm will display if the chamber pressure exceeds 240 kPa
  • Safety valve opens as backup protection should the chamber pressure exceed 262 kPa
  • Chamber temperature is monitored by a surface sensor with overheat protection should the temperature of the heating elements reach 180°C
  • In case of electrical power interruption during the sterilization cycle, pressure in the chamber is automatically vented to the atmosphere and display is blank
  • Optional time/temperature recorder for office documentation
  • Designed and built to ASME specifications
  • Six month replacement / three year limited parts warranty

SPECIFICATIONS
 
Delta Q 8
Delta Q 10
Chamber Size
8.25 x 14 in.(21 x 36 cm)
9.875 x 17.5 in. (25.1 x 44.5 cm)
Chamber Capacity
739 cu in. (12,110 cu cm)
Holds 2 European trays

1340 cu in. (22,019 cu cm)
Holds 3 large or 9 small Hu-Friedy cassettes or 3 European trays

Start-Up Time (to 134°C)
10-13 minutes warm
12 minutes warm
Sterilization Time
16 minutes warm (unwrapped)
16 minutes warm (unwrapped)
Drying Cycle Time
30 minutes preprogrammed, variable 0-99 minutes
30 minutes preprogrammed, variable 0-99 minutes
Outside Dimensions (WxDxH)
17.5 x 19.75 x 12.25 in.
44 x 50 x 31 cm
19.25 x 23.625 x 14 in.
49 x 60 x 36 cm
Electrical
110-120 VAC, 50/60Hz (ETL/cETL)
220-240 VAC, 50/60Hz (ETL/cETL)
110-120 VAC, 50/60Hz (ETL/cETL)
220-240 VAC, 50/60Hz (ETL/cETL)