| Gas Detection |
| Model Ventis |
![]() |
![]() |
| Presentation |
| The Ventis Diner is proud to serve up safety all day, every day. Established in 2011, the Diner’s already famous Ventis MX4 gas detector perfectly satisfies those carvings for a small, reliable multi-gas instrument to be used in a variety of applications. At the Diner, we understand that each of our patrons have unique gas detection needs. That’s why The Gas Detection People are so pleased to be able to meet those needs with the highly configurable Ventis. When ordering the instrument, select a powerful, yet lightweight pump for easy monitoring in confined spaces; choose a safety orange overmold for increased visibility of your fleet; or pick from a wide range of sensors to ensure safety in a variety of environments. Best of all, you may order the Ventis with iNetTM – Industrial Scientific’s software-based service that increases safety by providing visibility into alarms, exposure and usage. With iNet, patrons are delighted to find that they do not have to buy the Ventis ad instead can subscribe to Gas Detection as a Service for a monthly fee. We invite you to stop in to view our menu which includes the many ways the Ventis and Inet can meet your specific gas detection needs. Need a faster way to curb your appetite? |
| Specification |
| Versions | |
| Ventis: Served with a calibration cup, calibration tubing, service tool and reference guide Ventis with a pum: Served with sample tubing, calibration tubing, service tool and reference guide |
|
| Sensors | |
| Combustible gases (Select one): LEL (Pentane), LEL (Methane), CH4 (0-5%) Toxic gases (Select two): CO, H2S, SO2, NO2 Oxygen: O2 |
|
| Batteries | |
| Rechargeable lithium-ion battery: Up to 12 hours of run time without pump Rechargeable extended-range lithium-ion battery: Up to 12 hours of run time with pump or 20 hours without pump Replaceable AAA Alkaline battery pack: Up to 4 hours of run time with pump or 8 hours without pump |
|
| Colors | |
Black...................................................................................................................................................... |
|
| Reference guide languages | |
| Language (Select one): English, French, Spanish, German, Italian, Dutch, Portuguese, Russian, Polish, Czech, Chinese, Danish, Norwegian, Finnish, Swedish | |
| Docking station | |
| Optimize nearly any size gas detector fl eet using a Docking Station that provides consistent and automated calibration, record keeping, diagnostics and battery recharging. | ![]() |
| Calibration stations | |
| Calibrate and bump test the Ventis with or without the pump using the stand-alone station designed for use with the respective confi guration. | |
| Chargers | |
| Prepare your Ventis and/or gas detector fl eet for operation by choosing from a number of charger options which range from a simple single-unit charger to a robust six-unit charger. | |
| Cases | |
| Select a soft or leather carrying case to ensure protection of your instrument no matter the environment. | |
| Confined space kits | |
| Simplify confi ned space monitoring using a kit which includes the Ventis with a pump, universal charger, soft carrying case, service tool, reference guide, calibration tubing, dust fi lter/water stop, calibration fi tting, sample tubing, calibration gas (appropriate mix) with regulator and rugged case. | ![]() |
| Perfect for personal or confi ned space entry monitoring, the Ventis is useful in a variety of industries. The Ventis Diner offers classic diner selections that can be commonly used in the following industries and applications. | |
| Construction | |
| Confi ned space entry (trenching, tank entry): O2, LEL, CO, H2S or NO2 Personal monitoring: O2, LEL, CO, H2S or NO2 |
|
| Electrical / Gas utilities | |
| Coal storage (coal loading, bin inspection): CO, CH4 Boiler operations (confi ned spaces, boiler startup, maintenance): O2, LEL, CO, SO2 or NO2 Confined space entry (transmission, distribution, maintenance, turnaround, transformer vaults, manholes): O2, LEL, CO, H2S Pipeline construction (trenching): O2, LEL, CO, H2S |
|
| Steel Production | |
| Blast furnace (operations and maintenance): O2, LEL, CO, SO2 or NO2 Pits (pit inspection, maintenance): CO, O2 Confined space entry (maintenance, turnaround): O2, LEL, CO, H2S Personal monitoring: O2, LEL, CO, H2S, NO2 or SO2 |
|
| Oil and gas production | |
| Drilling (spudding, drilling, flaring): O2, LEL, H2S, SO2 Transportation, storage and distribution (pipelines, tanker truck, tank farms, pipeline monitoring: O2, LEL, H2S, SO2 Confined space entry (maintenance, turnaround): O2, LEL, CO, H2S |
|
| Chemical | |
| Hot work (“live” pipes, tank work): O2, LEL, CO, H2S Confined space entry (tank/vessel entry): O2, LEL, CO, H2S, SO2 or NO2 Personal monitoring: O2, LEL, CO, H2S or SO2 |
|
| Fire services | |
| Confined space entry (confi ned space rescue): O2, LEL, CO, H2S Carbon monoxide response: CO Hazmat: O2, LEL, CO, H2S, SO2 or NO2 Gas leak response: O2, LEL |
|
| Water / Waste water treatment | |
| Storm and waste water collection (dry/wet wells, manholes, sumps WWT plants): O2, LEL, CO, H2S or SO2 Confined space entry (meter pits, vaults, underground tunnels, access ways, dry/wet wells): O2, LEL, CO, H2S |
|
| Features |
![]() |