GENEQ > Environnement > Alarmes

Alarme de variation de température FreezeAlarm™ Deluxe
Modèle FA-D


The Deluxe Freeze Alarms will dial out to three phone numbers when the temperature gets out of range, if the power goes out (immediate or 45 minute delay), or if the back-up battery needs replacing. Additional features include the ability to switch a relay by telephone, making this perfect for switching between two different thermostats, one set for high and one set for low - effectively being able to heat up or cool down a home before you arrive.

Also includes a normally open auxiliary alarm input for hook up of other alarms, such as a water alarm, a motion sensor or a door open sensor. Anything that closes the contact will activate the auxiliary alarm, call out to your phone list and then play a custom recorded message related directly to the activated alarm device. Units include a transformer for a standard wall outlet and require a 9 volt alkaline battery for back-up power. Units will only work on an existing, standard, single telephone line. This alarm can monitor both a temperature rise and fall simultaneously with a temperature range of -45 to 93°C (-49° F to 199°F).


APPLICATIONS
Applications include remote temperatue, power, and security monitoring of refrigeration, heating and air conditioning equipmen for buildings (homes, cabins, and commercial buildingd) and monitoring of any relay output system or sensor. The remote switch control feature can be used to control thermostats or equipment from any Touch Tone™ phone (additional parts and labor my be needed).

FEATURES
  • Adjustable high & low temperature alarm setpoints
  • Three telephone number call out, up to 16 digits each
  • Power loss call out alarm
  • Low battery call out alarm
  • Remote access to programming menu and current conditions status
  • Monitors an open contact
  • Remote control switch relay
  • Location identification number
  • Custom voice message recording
  • Selectable 15 minute or 2 hour call out interval
  • Selectable 10 or 3 ring call out
  • Security coded access to programming menu
  • Dials out in pulse or tone
  • LED status indicators
  • Battery back-up (9 volt included)

SPECIFICATIONS
Power Requirements Plugs into standard 110 VAC outlet (plug-in wall transformer with six foot long cord included)
Sensor Semi-conductor sensor with 1.75 x 0.25 in. nickel plated cooper cap and three foot cord
Operating Range of Sensor -45 to 93°C (-49 to 199°F)
Accuracy ±2°C/F
Remote Switch SPDT, 10 amps 24 volts resistive
Ambient Temp. Range 0 to 60°C (32 to 140°F)
Humidity 90% non-condensing
Weight 3.0 lbs (1.4kg)