GENEQ > Biotechnology > Analytical Balances
| Ohaus Discovery Balances |
The Professional's Choice For Analytical
Applications ! |
| The NEW Ohaus Duscovery
series of semi-micro and analytical balances combine unmatched weighing
performance with Ohau's innovative SmarText™ software, making it
extremely reliable and easy-to-use. The Discovery features durable glass
and steel construction and together with advanced AutoCat™ internal
calibration make it the best performing balance in its class: |
| Highest Performance with repeatability and linearity performance that's 2x better than most balances in its class |
| SmarText™ Software utilizes text prompts to guide users throught application use and balance setup |
| Advanced AutoCal™ automatic internal calibration ensures accurate weighing |
The Ohaus Discovery series features
four analytical models with capacities up to 310g by 0.1 mg with a FineRange™
model that offers 10 microgram readability. Discovery is perfect for university
research, pharmaceutical research and drug discovery, and general lab
applications. |
![]() |
Key Feautures |
|
Highest Performance Discovery's repeatability and linearity
performance is 2x better than most semi-micro balances in its class. Glass
and steel construction resists the effects of static and corrosion increasing
balance stability and accuracy , as well as extending product life. SmarText™ is Ohaus' easy tu use
balance software that utilizes text prompts to guide users through application
use and balance setup. Delivered through a 2-line backlite LCD and clearly
marked buttons, SmarText™tells you what is going on and what you
have to do next. To minimize weighing errors and ensure
accurate measurments, AutoCal™ utilizes two internal weights to
performa a linear calibration. |
| Application Modes |
| Statistics |
|
Statistics are used when
it is desired to compare a number of samples and examine the relative
deviation of the samples along with other statistical data. A minimum
of three samples are required in this program. Statistics contains menu
options which include: number of samples, maximum, minimum, difference,
sum, mean, standard deviation, relative deviation, auto sample, and auto
print. In addition to standard weiighing, statistical data can be provided for Aniam/Dynamic Weighing and Chechweighing measurements. |
| Density |
| Discovery provides users four methods
of density determination to choose from depending on their need. They are: 1: User can determine density for solids more dense than water 2: User can determine density for solids less dense than water 3: User can determine density for liquid density (sinker needed - not included) 4: User can determine density for Porous material ( impregnated with oil_. After entering a couple pf parameters into the balance, the built in density table, and mass measurement of the balance take over to provide rapid and accurate density results, with non manual calculations needed. |
| Pipette Calibration |
|
Pipette calibration checks the accuracy
and precision values of pipettes by weight analysis. The Discovery DV215CD
0.01mg semi-micro balance is recommended for maximum accuracy. To calibrate
a pipette, the user will select the type of liquid to be used in the pipette
(normally water), barometric pressure, nominal value, and unit of measure
of the pipette. The balance will do the rest. The Discovery will accept
an alternate liquid's density in g/cc at current room temperature as well. |
| Percent Weighing |
|
This mode allows the user to display
the weight of a sample as a percentage of a reference weight useful in
sieving applications, reagent weighing, moisture determination, and other
types of ingredient mixing. |
| Parts Counting |
|
Parts counting mode is useful when
counting pills, or parts that have a consistent, but low nominal mass.
This mode allows the user to count based on a calculated piece weight.
The optimization feature improves counting accuracy by automatically re-calculating
the piece weight as parts are added. |
| Check Weighing |
|
This mode allows the user to check
the weight of a sample against preset traget parameters such as underweight
and overweight. |
| Animal/Dynamic Weighing |
|
Dynamic weighing can
be used when either a rough environment is encountered such as on a ship,
or when in a location that may not have ideal conditions. In addition,
this mode allows the user to weigh moving objects such as animals, insects
or other moving specimens. Dynamic weighing averages out weight readings
over a period of time and displays the results until cleared. |
| Totalization |
|
This mode allows the
user to sum a series of samples weights that can be greater than the capacity
of the balance. Totalization is helpful when adding the masses of several
samples together without the need for a calculator. |
| High Point |
|
High Point can be used when analysing
batches or lots, or for quality chechking of random samples. When in HIgh
Point mode, the balance will save only the highest weight value from a
series of weighings. |
| Connectivity |
|
Discovery comes with an included RS232
interface and provides full GLP/GMP date output |
| Specifications | ||||
| Model | DV114C |
DV214C |
DV314C |
DV215CD |
| Capacity (g) | 110 |
210 |
310 |
81* /210 |
| Readability (mg) | 0.1 |
0.1 |
0.1 |
0.01* /0.1 |
| Repeatability (Std.dev) (mg) | 0.1 |
0.1 |
0.2 |
0.02* /0.1 |
| Linearity (mg) | ±0.2 |
±0.5 |
±0.03* /0.2 |
|
| Weighing UnitsApplication Modes |
Miligramm, Gram, Carat, Ounce, Ounce
Troy, Grain, Pennyweight, Momme, Hong Kong Tael, Singapore Tael, Taiwan
Tael, Custom |
|||
| Application Modes | Weighing, Parts Counting
with Automatic Sample Recalibration, Percent Weighing, Checkweighing,
Animal/Dynamic Weighing, Gross/Net/Tare Weighing, Totalization, High Point,
Density, Statistics, Pipette Calibration |
|||
| Features | Selectable Environmental
Filtrers, RS232 Interface with full GLP/GMP Protocol, Easy to Clean Stainless
Steel Platform, Windring and Glass & Steel Construction, Protective
In-Use Cover, Integral Weigh Below Hook, Easy to Use Keypad, Up-Front
Level Indicator |
|||
| Tare Range | To
Capacity by Subtraction |
|||
| Stabilization Time (s) | 4 |
8 |
12/5 |
|
| Sensitivity Drift (10 -30ºC) | ±2ppm/ºC
|
|||
| Operating Temp Range |
10º to 40º C |
|||
| Calibration |
Automatic internal, Pushbutton internal,
Manual external |
|||
| Power Requirements | External Adapter, 100-120VAC
150mA, 220-240VAC 100mA, 50/60 Hz Plug configuration for US, Euro, UK,
Japan & Australian |
|||
| Display Type | 2-line Alphanumeric Backlit
LCD Display |
|||
| Display Size (in/cm) | 4 x 1 / 10 x 2.5 |
|||
| Pan Size (diameter) (in/cm) | 3.5 / 9 |
|||
| Height above pan (in/cm) | 9.5 / 24 |
|||
| Dimension WxHxD (in/cm) | 7.9 x 11.8 x 18 / 20 x
30 x 45.7 |
|||
| Net Weight (lb/kg) | 22.5 / 10.2 |
|||
* Fine
Range |
||||
| Other Standard Features and Equipment | |
| Stability
indicator, mechanical and software overload/underload protection, AC adapter,
user selectable span calibration points, auto tare, auto shut-off, user
selectable printing options, user selectable communications settings,
user selectable data print options, user definable project and user ID's,
software reset menu, softwarelockout menu |
|
| Approvals | |
| CE, FCC, CULUS, CCSAUS, NRTL, OIML | |
| Accessories | Ohaus Number |
| Impact printer, 42 column | SF42 |
| RS232 cable, SF42 printer | 80500571 |
| TAL Software WinWedge | SW12W |
| SF42 printer paper (5 pack) | 12101511 |
| SF42 printer ribbon | 12101512 |
| RS232 cable, IBM 9 pin | 80500525 |
| RS232 cable, IBM 25 pin | 80500524 |
| Density determination kit | 77402-00 |
| Storage Cover | 9773-79 |
| Security device | 77401-00 |
| 100g Calibration Mass, ASTM Class1 | 49015-11 |
| 200g Calibration Mass, ASTM Class1 | 49025-11 |
| Industry Leading Quality and Support |
All Ohaus Discovery balances are manufactured
under an ISO 9001:2000 Registered Quality Management Ststem. OUr rugged
construction and stringent quality control have been hallmarks of all
Ohaus products for nearly a century. |