GENEQ > Environment > Data loggers
DOT Logger
![]() |
| Features | Applications |
|
|
| Description | |
|
The Stevens Data Online Telemetry (DOT) Logger is a flexible, compact, and inexpensive data logger specifically designed for accurate measurements from a variety of sensors. The DOT Loggers design includes four analog and four pulse count inputs, and can monitor up to ten SDI-12 sensor parameters in remote environmental applications. The DOT Logger telecommunicatiosn options include satellite transmitters
(geostationary such as GOES or low earth orbiting such as ORBCOMM),
cellualar or PTSN modem, or radio (UHF, VHF, spread specturm). Free
software that is shipped with the DOT Logger includes DOT SET for
easy set up and configuration of the DOT Logger and Stevens Logger
Read for simple exchange of data between the DOT Logger and a computer.
The data downloaded to the PC can easily be viewed in a comparable
tabular This flexible data collection package with the telemetry options easily brings the remote site monitoring information to your computer and/or standard web browser software. |
|
| DATA
MANAGEMENT SOFTWARE APPLICATIONS Storage, management and basic analysis of data are accomplished using Windows based software (Stevens Logger Read for direct connection to a remote station, and DaqLab for base station communications with a network of remote stations). Stevens also provides a data managment service where the remote station data is transmitted to a data warehouse that the user can access, analyze and download through a secured Internet URL (for an example see owrd.e-monitoring.net without the "www") |
| Technical Specifications | |
| Power Requirments |
10 - 17 VDC, <0.5mA standby current (telemetry system may require additional power) |
| On-Board Data Storage |
FLASH EPROM, 256k Bytes, capable of storing 60,000 readings |
|
Recording Interval |
1, 5, 6, 10, 15, 30 seconds 1, 5, 6, 10, 15, 30 minutes 1, 2, 4, 6, 8, 24 hours |
| Real-Time Clock |
Accurace +/- 1 minute/month, leap year correction |
| Non-Volatile Memory | All setup parameters and clock, lithium battery |
| Message Size | 6 - 250 bytes typically, no maximum |
| Serial Port | RS-232, minimun +/- 5 VDC levels, 300 to 9600 baud |
| Analog to Digital (A/D) Bits | 12 |
| Communications | RS-232 (MODBUS optional) |
| Temperature and Humidity |
Operating: -40 F to 158 F (-40 C to 70 C) NEMA 4 enclosure: 100% condensing Aluminum enclosure: 95% non-condensing |
| Sensor Input Selections | |
| Four (4) Analog - Signal Ended: | Input type: 2 wire, 4 - 20 mA current loop Sensor power: 24 VDC, under firmware control Accuracy & Resolution: 0.25% accuracy, 0.1% resolution |
| Four (4) Pulse Count: | Input type: pulse Sensor power: 5 or 12 VDC continuous Maximum rate: 30 pulses per minute |
| Ten (10) Serial: | Input type: SDI-12 Sensor power: 12 VDC continuous, 5 or 12 VDC under firmware control (switched) |
| One Switch Excitatio Voltage: | 5 or 12 VDC |
| Physical Size (L x H x D) | NEMA 4 - 6.3 in x 3.2 in x 2.3 in (160.2 mm x 80.1
mm x 58.2 mm) Black housing - 6.3 in x 4.2 in x 1.3 in (159.0 mm x 105.2 mm x 33.7 mm) |
| ORDERING INFORMATION | |
| Part number | Description |
| ST92961-00 | DOT with NEMA 4 enclosure |
| ST3273-00 | DOT with Black anodized aluminum enclosure |