| Drive-Point Profiler |
| Model 660 |
![]() |
![]() |
| Description |
The Model 660 Profiler is designed to be a preliminary site
assessment tool. It enables the collection of groundwater
samples from multiple points in a single drive/drilling location,
at discrete zones. Profiler transects allow:
high resolution sampling
contaminant vs. depth profiling
detailed plume delineation |
| Sealing Profiler Holes |
| Holes in most homogeneous sands will collapse as soon as the Profiler is withdrawn. In other geologic formations it is best to use a Grout Tip Profiler. The grout tip model has a single use tip that can be separated from the Profiler by injecting grout under pressure using a grout pump, after sampling is complete. This allows the hole to be sealed as the Profiler is being withdrawn, to ensure no void spaces. |
| Depth Discrete Sampling |
| Profiling can start at ground surface, or to save time, it can
begin at the bottom of a pre-drilled hole. To avoid downward drag and cross contamination, the Profiler system is flushed with deionized water using a Peristaltic Pump while it is being driven between sampling zones. When the desired depth is reached, the pump flow is reversed. The resulting water flow to surface is monitored for clarity and conductivity. When all deionized water is removed from the system and purge parameters have stabilized, the sample is taken. After sampling, the water flow is reversed and once again deionized water is used to flush the Profiler tip, to keep it from clogging. Tests have proven virtually no ‘drag down’ if correct procedures are followed. |
| Depth Limitations |
| Most drill rigs with AW rod will have the capability to advance
the Profiler. A tubing by-pass will be required to allow the
sample line to exit the rods.
Drive-Point Profilers are not suitable for all sites. Depth
limitations vary with soil conditions and the drive technology
used. Using a peristaltic pump to flush and sample is effective
if the water level in the borehole is within 26 ft. (8 m) of
surface. There is no minimum separation between sample depths, which makes the Model 660 ideal for high resolution profiling. |