Geneq > Environnement > Spectrophotomètres

Spectrophotomètre portable modèle DR 2800™
 


The Hach DR 2800 Portable Spectrophotometer offers automatic method detection when used with TNTplus reagent vials. It also has an intuitive touch screen user interface and accommodates a wide range of pre-programmed water analysis methods. The small footprint is an advantage whenever you need a reliable portable analytical tool.

Features
More than 240 Analytical Methods and Chemistries
The Hach DR 2800 Portable Spectrophotometer can be used for more than 240 analytical methods. (Test parameters are listed on page 3.) These methods include more than 30 TNTplus™ reagent vial tests that provide innovative barcode labeling for reliable, automatic method detection. All of the chemistries and supplies needed for these tests are available from Hach. The spectrophotometer can store up to 50 user programs and 500 data points, including sample and operator ID.
Use a USB Memory Stick to Update the Instrument or Transfer Data
Easily update DR 2800 spectrophotometer systems and transfer measurement data with a USB memory stick. Use it to stay current as Hach releases new test methods and chemistries. Two USB ports on the instrument allow for a computer to be connected in one port, when used with an upcoming software package, while the other is used to connect the spectrophotometer to a memory device or hand-held bar code scanner.
Small Footprint and Large Touch Screen Interface
The small footprint of the DR 2800 spectrophotometer— only 8.7 by 13.1 inches—lets it easily fit into any lab as well as being completely portable. The touch screen display is intuitive to use and ergonomic in design.
Runs on Either Line Power or Battery Power
Use the DR 2800 spectrophotometer in the lab with regular line power or in the field with the optional lithium-ion battery.
Accommodates Multiple Cell Sizes and Sample Delivery Methods
The DR 2800 spectrophotometer holds eight types of Hach cells—including 1-in. square cells, 1x5-cm cells, 13-mm round vials (TNTplus), and 16-mm round vials. Three adapters are included with the spectrophotometer for other vial types such as 1-in. round/AccuVac® cells, multipath 1-in./1-cm cells, 1x1-cm square cells, and Pour-Thru™ cells. The optional Pour-Thru cell kit is ideal for rapid liquid methods when high throughput of analysis is needed.
TNTplus Reagent Vials Designed for the DR 2800 Spectrophotometer
Hach has developed TNTplus reagent vials for selected analytical methods that provide the following features when used with the Hach DR 2800 Portable Spectrophotometer:
• Automatic method detection—the spectrophotometer automatically reads the bar code, identifies the appropriate method, and takes the measurement to help eliminate human error, saving time and money.
• No reagent blank is necessary—high quality vials, tight regent production controls, 10-absorbance readings averaged for results determination, instrument calibration verification, and negligible instrument drift, all combine to eliminate the need to run reagent blanks.
• Built-in accuracy—while rotating the vial, the spectrophotometer takes 10 absorbance measurements in less than 5 seconds. The average value is used to calculate the results.

Specifications
Operating Mode
Transmittance (%), Absorbance and Concentration
Source Lamp
Tungsten
Pre-Installed Programs
More than 240
Available User Programs
50
Data Storage
500 points
Export Capability
.csv (comma-separated values) file format
Wavelength Range
340 to 900 nm
Wavelength Accuracy
±1.5 nm
Wavelength Resolution
1 nm
Spectral Bandwidth
5 nm
Wavelength Calibration
Internal, automatic at power-on, visual feedback
Wavelength Selection
Automatic: based on selected program
Automatic: based on barcode printed
on TNTplus™ reagent vials
Manual: in all modes except stored programs
Enclosure Rating
IP 41
Operating Temperature
10 to 40°C (50 to 104°F)
Operating Humidity
80% relative humidity, non-condensing, maximum
Storage Requirements
Temperature: -25 to 60°C (-13 to 140°F)
Humidity: 80% relative humidity, non-condensing, maximum
Power Requirements
Line: 100 to 240 V; 47/63 Hz; automatic changeover
Battery: Lithium-Ion 11V/4400mAh
Interface
USB 1.1 (10 ft. (3 m) cable, maximum)
Languages
English, French, German, Italian, Spanish, Portuguese, Chinese, Japanese, and Korean (please contact your Hach representative for availability of additional languages)
Connections
1 x USB type B (PC)
1 x USB type A
(USB storage device, printer, keyboard)
Sample Cell Compatibility
1-in. square
1-in. round
1 cm square
1x5 cm
13 mm round
16 mm round
Multipath 1-in./1 cm
Pour-Thru™ with 1-in./1 cm path lengths
Accessories
Included:
– 1-in. square matched glass sample cells
– Cell adapters for 1-in. round/ AccuVac cells, 1x1 cm cells, and multi-path 1-in./1 cm cells
– Universal power supply, 100 to 240V, 47/63Hz, with plug adapters for EU, GB, US, China
– Protective cover for storing adapters
– Dust cover
Optional:
– Hach Pour-Thru cell
– External USB keyboard
– Rechargeable lithium-ion battery
– Carrying Case
– DataTrans™ Software
Dimensions
220 x 137 x 332 mm (8.7 x 5.4 x 13.1 in.) width, height, depth
Weight
Without battery: 4.06 kg (8.95 lbs.)
With battery: 4.38 kg (9.65 lbs.)

Engineering Specifications
  1. The spectrophotometer instrument shall be a multi-wavelength spectrophotometer designed for laboratory or field analysis of multiple analytes.
  2. The instrument shall be capable of measuring the following substances or characteristics: alachlor; aluminum; arsenic; atrazine; barium; benzotriazole; boron; bromine; cadmium; chloride; chlorine dioxide; chlorine; chromium; cobalt; color; copper; cyanide; cyanuric acid; dissolved oxygen; fluoride; formaldehyde; hardness; hydrazine; iodine; iron; lead; manganese; mercury; molybdenum/molybdate; monochloramines; nickel; nitrogen (as ammonia, nitrate, nitrite, total nitrogen, total Kjeldahl nitrogen); chemical oxygen demand; oxygen scavengers; ozone; polychlorinated biphenyls; phenols; phosphonates; phosphorus; potassium; quaternary ammonium compounds; selenium; silica; silver; sulfate; sulfide; surfactants; suspended solids; tannin and lignin; total organic carbon; tolyltriazole; total petroleum hydrocarbons; trihalomethanes; toxicity; volatile acids; and zinc.
  3. The following tests shall conform to USEPA-compliant methods: arsenic; chlorine (free); chlorine (total); chlorine dioxide; chromium (hexavalent); copper; fluoride; iron (total); lead; manganese; nickel; nitrogen (ammonia); nitrogen (nitrite); chemical oxygen demand; phenols; phosphorus (reactive); phosphorus (total); sulfate; sulfide; and zinc.
  4. The wavelength range of the instrument shall be 340 to 900 nm with accuracy of ±1.5 nm, resolution of 1 nm, and maximum bandwidth of 5 nm.
  5. The instrument, depending on the test selection, shall automatically select the wavelength.
  6. Readout modes shall include transmittance, absorbance, and concentration.
  7. The interface of the instrument shall be graphical with touch screen.
  8. The instrument shall provide graphical display and be capable of printing test results.
  9. The instrument shall be equipped with storage capacity for 500 data points (date, time, results, sample ID, user ID) and 50 user-defined calibrations.
  10. Information stored in the instrument shall be capable of being downloaded in standard report format.
  11. The instrument shall be capable of accepting 1-in. (25 mm) round cells/vials, 1-in. square cells, 13 mm round vials, 16 mm round vials, 1x5 cm cells, and Pour-Thru cells with 1-in./1 cm paths.
  12. Power requirement shall be line voltage or optional battery pack.
  13. The instrument shall be warranted for one full year against defects in materials and workmanship.

Available Tests
The following table lists available tests and overall ranges for the Hach DR 2800 Portable Spectrophotometer. The ranges may represent more than one available test for the instrument. Consult your Hach representative, Customer Service, the Hach Master Catalog (Lit. #2550), or the Hach web site at www.hach.com for complete details of all available tests for this instrument.

Ordering Information
DR 2800-01B1 DR 2800 Portable Spectrophotometer; includes printed instrument manual, procedure manual on CD-ROM, universal power supply with exchangeable plug adapters for EU, GB, US, and China, dust cover, and 1-in. square matched glass sample cells, includes a Lithium-ion Battery Pack
Replacement Parts
LZV610 Power Supply; 100 to 240V, 47 to 63 Hz, international (exchangeable plug adapters for EU, GB, US, and China)
LZV583 Adapter A; 1 cm square cells
LZV585 Adapter B; multi-path cell, 1-in./1 cm, or Pour-Thru cell
LZV584 Adapter C; 1-in. round cells
LZV565 Replacement Bulb; 6V, 10W
LZV642 Protective Cover for storing adapters
LZV646 Light Shield
HYH019 Dust Cover
Optional Accessories
5940400 Pour-Thru Cell Kit; includes 1-in. Pour-Thru cell, holder, funnel, and tubing
LZV537 Certified Test Filter Set
2960100 Citizen PD-24 Printer Package
LZV582 USB Keyboard
LZV566 USB Hand-held Barcode Scanner
LZV551 Battery Pack (lithium-ion 11 V/4400 mAh)
5839700 DR 2800 Carrying Case
LZY274 DataTrans™ Software