Spectrophotomètre de laboratoire
modèle DR 5000™ UV-Vis


The Hach DR 5000 UV-Vis Laboratory Spectrophotometer offers a broad range of water analysis methods with more than 240 pre-programmed tests. Automatic method detection capability with TNTplus reagents reduces test time and potential errors. The intuitive touch screen interface makes this instrument easy to use.

Features
More than 240 Analytical Methods and Chemistries
The Hach DR 5000 UV-Vis Laboratory Spectrophotometer can test for all of the parameters listed on page 3. All of the chemistries and supplies needed for these tests are available from Hach.
Easily Add New Analytical Methods
As Hach releases new test methods and chemistries, the DR 5000 spectrophotometer can easily be updated via a USB memory stick.
Stability and Accuracy
The design of the DR 5000 spectrophotometer ensures measurements are accurate, precise, and stable over time, resulting in repeatable results.
Multiple Cell Sizes and Delivery Methods
A single multi-cell adapter for the DR 5000 spectrophotometer holds the five most common sample cell types, including 5 cm path length cells. Moreover, the optional Pour-Thru™ Cell Module is ideal for Rapid Liquid™ methods.
Large Touch Screen Display and Interface
The touch screen display of the DR 5000 spectrophotometer is intuitive to use and ergonomic in design.
High-Speed Wavelength Scanning
The DR 5000 spectrophotometer features full-range wavelength scanning from 190-1100 nm. Use this feature to develop custom methods or maintain consistency of colored products.
TNTplus™ Reagent Vials Designed for the DR 5000 Spectrophotometer
Hach has developed TNTplus™ reagent vials for more than 30 selected analytical methods that provide the following features when used with the DR 5000 spectrophotometer:
  • Increased productivity and confidence in results— testing with TNTplus reagents takes less time, and potential errors are reduced.
  • Automatic method detection—the DR 5000 spectrophotometer automatically reads the bar code, identifies the appropriate method, and takes the measurement.
  • No reagent blank is necessary.
  • Built-in accuracy—while rotating the vial, DR 5000 spectrophotometer takes 10 absorbance measurements in less than 5 seconds. The average value is used to calculate the results.

Specifications
Operating Mode
Transmittance (%), Absorbance and Concentration
Source Lamp
Tungsten (visible) and Deuterium (UV)
Pre-Installed Programs
More than 240
Available User Programs
50
Data Storage
1000 points
Scan Data Storage
20 Scans
Export Capability
.csv (comma-separated values) file format
Wavelength Range
190 to 1100 nm
Wavelength Accuracy
±1 nm in wavelength range 200-900 nm
Wavelength Resolution
0.1 nm
Wavelength Calibration
Automatic
Wavelength Selection
Automatic–based on selected program Manual–in all modes except stored programs
Scanning Speed
900 nm per minute in 1 nm steps
Spectral Bandwidth
2 nm
Photometric Range
±3.0 Abs in wavelength range 200-900 nm
Photometric Accuracy
5 mAbs at 0.0 to 0.5 Abs
1% at 0.5 to 2.0 Abs
Photometric Linearity
Deviation less than 0.5% up to 2 Abs
Deviation less than or equal to
1% at greater than 2 Abs
Stray Light
KI-solution at 220 nm: greater than
3.3 Abs / less than 0.05%
Enclosure Rating
IP 31
Multiple Language Interface
English, Spanish, French, German, Italian, Portuguese, Chinese, Japanese, Korean (please contact your Hach representative for availability of additional languages)
Operating Temperature
10 to 40°C (50 to 104°F)
Operating Humidity
80% relative humidity (non-condensing) maximum
Storage Requirements
-25 to 60°C (-13 to 140°F)
80% relative humidity (non-condensing) maximum
Power Requirements
100 to 120 V or 200 to 240 V; 50/60 Hz; automatic changeover
Interface
USB 1.1
Connections
1 x USB type B (PC)
2 x USB type A (USB storage device, printer, keyboard, barcode scanner)
Sample Cell Compatibility
1 x 1 cm, 2 x 1 cm, 5 x 1 cm,
10 x 1 cm (with optional adapter)
13 and 16 mm round
1-in. round
1-in. square
AccuVac®
Pour-Thru™ with 1-in. and
1 cm path lengths
Accessories
Sipper Module with 1 cm cell
Carousel Holder (sample changer)
(Seven 1 x 1 cm cells)
Pour-Thru™ Cell Module, 1-in. or 1 cm
Brewery Analysis Software
DataTrans™ Software
Printer: USB (PCL3 Language)
External keyboard: USB
External barcode reader: USB
Dimensions
450 x 200 x 500 mm
(17.7 x 7.9 x19.7 in.) width, height, depth
Weight
15.5 kg (34.2 Ib.)

Engineering Specifications
  1. The spectrophotometer instrument shall be a multiwavelength, UV-Visible, reference beam spectrophotometer designed for laboratory analysis of multiple analytes.
  2. The instrument shall be capable of measuring the following substances or characteristics: alachlor; aluminum; arsenic; atrazine; barium; benzotriazole; boron; bromine; cadmium; chloramine (mono); chloride; chlorine dioxide; chlorine; chromium; cobalt; color; copper; cyanide; fluoride; formaldehyde; hardness; hydrazine; iodine; iron; lead; manganese; mercury; molybdenum; nickel; nitrogen (as ammonia, nitrate, nitrite, total nitrogen, total Kjeldahl nitrogen); dissolved oxygen; chemical oxygen demand; oxygen scavengers; ozone; pcb (polychlorinated biphenyls); phenols; phosphonates; phosphorus; potassium; quaternary ammonium compounds; selenium; silica; silver; sulfate; sulfide; surfactants; suspended solids; tannin and lignin; total organic carbon; tolyltriazole; total petroleum hydrocarbons (TPH); trihalomethanes (THM); toxicity; volatile acids; and zinc.
  3. The following tests shall conform to USEPA-compliant methods: arsenic; chlorine dioxide; chlorine, free; chlorine, total; chromium, hexavalent; copper; fluoride; iron (total); manganese; nickel; nitrogen (ammonia); nitrogen (nitrite); chemical oxygen demand; phenols; phosphorus (reactive); phosphorus (total); sulfate; sulfide; and zinc.
  4. The wavelength range of the instrument shall be from 190 to 1100 nm with accuracy of ±1 nm and resolution of 0.1 nm.
  5. The instrument, depending on the test selection, shall automatically select the wavelength.
  6. Readout modes shall include transmittance (%), absorbance, concentration, optional wavelength scan and time course graphs.
  7. The interface of the instrument shall be graphical with touch screen.
  8. The instrument shall provide graphical display and be capable of printing test results.
  9. The instrument shall be equipped with storage capacity for 1000 data points (date, time, results, sample ID, user ID) and 50 user-defined calibrations.
  10. Information stored in the instrument shall be capable of being downloaded in standard report format.
  11. The instrument shall be capable of accepting 1-in. (25 mm) round cells/vials; 1-in. square cells; 13 mm round vials; 16 mm round vials; 1 cm square cells, 2, 5, and 10 cm rectangular cells; and Pour Thru cells with 1-in. and 1 cm path lengths.
  12. Power requirement shall be 100-240 Vac, 50/60 Hz.
  13. The instrument shall be warranted for one full year against defects in materials and workmanship.

Available Tests
The following table lists available tests and overall ranges for the Hach DR 5000 UV-Vis Laboratory Spectrophotometer. The ranges may represent more than one available test for the instrument. Consult your Hach representative, Customer Service, the Hach Master Catalog (Literature #2550) or the Hach web site at www.hach.com for complete details of all available tests for this instrument.

Ordering Information
DR5000-03 DR 5000 UV-Vis Spectrophotometer, 100-240 Vac; includes multi-cell holder, instrument manual, power cords (115V and 230V), 1-in. matched glass sample cells, 1 cm matched quartz sample cells
Optional Accessories
LZV478 Carousel Sample Changer; holds up to seven 1 cm square sample cells
LZV485 Sipper Module; includes 1 cm square quartz cell
LZV479 Pour-Thru Cell Kit, 1-in.
LZV789 Pour-Thru Cell Kit, 1 cm
LZY421 Cell Adapter for 10 cm x 1 cm rectangular cells
LZY274 DataTrans™ Software
Hach DataTrans Software transfers measurement output from Hach DR 2700, DR 2800, or DR 5000 spectrophotometers to a PC via USB port. This direct computer file input saves time and eliminates keying errors. Data can be transferred to an Excel spreadsheet or to LIMS. The software also displays wavelength scan and time course graphs, and underlying raw data points can be easily exported to Excel. A powerful search function allows customer to sort by: Result parameter), Date (range), Operator, Instrument (type, serial number), Program (name, type), and Sample name. For recurring searches, users may also create custom search programs and save under separate names.
LZV659 Brewery Analysis Package
The Brewery Analysis Software package is designed for breweries utilizing the Hach DR 5000 Spectrophotometer. This upgrade contains 12 specific brewery assays that conveniently upload via USB to a DR 5000. Assays are based on published and observed brewing methods and include procedures for:
  • Anthocyanogens
  • Iron
  • Steam volatile phenols
  • Beer color
  • Iso-alpha-acids
  • Total polyphenols
  • Bitterness units
  • Photometric iodine
  • Thiobarbituric acid number (TAN)
  • Free amino nitrogen
  • Reductones
  • Vicinal diketones
LZV537 Certified Test Filter Set
Consists of six filters for checking the absorbance accuracy, stray light, and wavelength accuracy. Designed for use with the standard 10mm cell holder. The set is supplied in a sturdy wooden case. For identification purposes, the filter name, set number and part number are printed on each filter mount. The absorbance values and/or peak position wavelengths of each filter are quoted in the accompanying calibration certificate.
2960100 Citizen PD-24 Printer Package
Includes printer, universal power supply, 115V power cord, battery pack, USB cable, RS232 cable with gender adapter, and one roll of thermal paper.