GENEQ > Environment > EMF Testers
| ElectroSmog Meter |
| Model TES-92 |
| • 50MHz to 3.5GHz • 3 dimensions measurement • Alarm / Memory function • Easy to Use |
Detects: Cellular Phone Transmission Station Microwave Oven Spy Camera, wireless bug Wireless Lan (Wi-Fi) |
| Feature |
• 50MHz to 3.5GHz Frequency range |
| Applications |
| • HIgh frequency (RF) electromagnetic wave field
strenght measurement • Mobil phone base station antenna radiation power density measurement • Wireless communication applications (CW, TDMA, GSM, DECT) • RF power measurement for transmitters • Wireless LAN (Wi-Fi) detection, installation • Spy camera, wireless bug finder • Cellular /Cordless phone radiation safety level • Microwave oven leakage detection • Personal living environment EMF safety |
| Electrical Specifications | |
| Sensor Type | Electric field (E). |
| Frequency Range | 50MHz to 3.5GHz |
| Directional characteristic | Isotropic, 3-dimensional |
| Meaurement range (CW signal > 50MHz) | 38mV/m to 11V/m. 3.8µW/m2 to 320mW/m2 |
| Absolute error (@1V/m and 50MHz) | ±1.0dB |
| Frequency response - taking into account typ. CAL factor | ±1.0dB (50MHz to 1.9GHz) ±2.4dB (1.9GHz to 3.5GHz) |
| Isotropy deviation | Typ.±1.0db for f >50MHz |
| Overload limit | 4.2W/m2 (40V/m) |
| Temperature response (0 to 50°C) | ±1.5db |
Note
: Unless otherwise stated, all specifications hold under the following
assumptions : Sinusoidal signals; device in far-field of a source; probe
head pointing toward source; ambient temperature +23°C±3°C;
relative air humidity 25% to 75% |
|
| General Specifications | |
| Measurement method | Digital, triaxial measurement |
| Directional characteristic | Isotropic, triaxial |
| Measurement range selection | One continuous range |
| Display resolution | 0.1mV/m, 0.1µA/m, 0.001µW/m2 |
| Setting time | Typically 1s (0 to 90% of meas. value) |
| Display refresh rate | Typically 400mS |
| Display type | LCD 4 digit |
| Audible alarm | Buzzer |
| Measurement units | mV/m, V/m, µA/m, mA/m, µW/m2. mW/m2 |
| Measurement display value | Instantaneous measured value, maximum value or average value since power-on. |
| Measurement average time (in per-set steps) | 4s to 15 minutes |
| Measurement alarm function | Adjustable threshold with ON/OFF |
| Measurement calibration factor CAL | Adjustable |
| Manual data memory and read storage | 99 sets (only recall by meter) |
| Battery | 9V |
| Battery life | >15 hours |
| Accessory | 9V battery, Carrying Case & Manaul |