| Environmental Chamber for temperature and humidity |
| Model Floor |
![]() |
![]() |
Select your optimum chamber from a full variation - this series provide three variations in temperature (& humidity) range of -35 to 150°C, -35 to 120°C, -60 to 150°C with upmost 20 to 98% RH. |
|
| Features |
User-friendly design
Control operation
|
|
| Description | TH-G/ I/ GU, TC-G/ GU series |
| Programmable pattern capacity | 120 |
| Pattern repeat time | 999 |
| Max. segments per a pattern | 100 |
| Available max. segments * | 1200 |
| Programmable process time per a segment | 0 to 99 hr 59 min |
Safety functions
|
|
| Specifications Model TH-G and TH-I |
![]() ![]() |
| 1) Technical data. (according to DIN 12880, IEC 60068) * CE Certification only for the TH-G-180, 300, 408 * Permissible Environmental Condition: Temperature 18 to 30°C (64.4 to 86°F), Maximum relative humidity 85% |
![]() ![]() |
| 1) Technical data. (according to DIN 12880, IEC 60068) * Permissible Environmental Condition: Temperature 18 to 30°C (64.4 to 86°F), Maximum relative humidity 85% |
| Specifications Model TH-GU-300 and TC-G |
![]() ![]() |
|
| 1) Technical data. (according to DIN 12880, IEC 60068) * Permissible Environmental Condition: Temperature 18 to 30°C (64.4 to 86°F), Maximum relative humidity 85% * Upon request, other sizes of chambers are available. Please contact with us. |
|
![]() ![]() |
|
| 1) Technical data. (according to DIN 12880, IEC 60068) * CE Certification only for the TC-G-180, 300, 408 * Permissible Environmental Condition: Temperature 18 to 30°C (64.4 to 86°F), Maximum relative humidity 85% |
| Specifications Model TC-GU-300 |
![]() |
|
| 1) Technical data. (according to DIN 12880, IEC 60068) * Permissible Environmental Condition: Temperature 18 to 30°C (64.4 to 86°F), Maximum relative humidity 85% |
| Accessories |
| Viewing window (Included) A tempered dual windows provided a clear view of your specimen during testing. Improved lighting provided. |
|
| Viewing window (Optional) A glass inner is provided inside the chamber door so that specimens can be observed. Applicable to TH-G, I-180, 300, 408L/ TC-180, 300, 408L and TH-CR-270 ONLY. |
|
Temperature and Humidity recorder (digital)
|
|
| Access Port A through hole of 50 or 80mm dia. (2.0 or 3.2" dia.) is provided on the wall of chamber to allow electrical cables to be introduced into the chamber. A 50mm hole is provided, maximum two holes (50 or 80mm) are optional.
|
|
| Water Supply Water supply system to supply pure water for humidification.
|
|
| Warning signal light A signal light to light up when malfunction occurs. Can be located upper plate of unit. |
|
| Wire shelf Stainless steel and electro polished shelf system is removed easily without using tools for easy cleaning. |
|