GENEQ > Biotechnology > Balances analytiques
GENEQ > Environment > Balance

Ohaus Explorer Pro Balances
 


The Explorer Pro Series features 4 analytical models with capacities up to 210g and 0.1mg readability for maximum accuracy. The new draftshield design and contoured fit provide optimum draft protection from wild currents for superior balance stability and reproducibility in challenging environments such as high traffic areas.

Percent Weighing
Percent weighing allows you to place a reference load on the pan, and check other samples as a percent of the reference load. Each new sample will be "percentage" of the original reference, the display shows the variance in ± percent of the reference.
Weighing
Basic Weighing with primary and secondary weighing units, time, date and capacity bar
Gross/Net/Tare
G/N/T is an application mode commonly used when you need to identifiey the idividual weights of the container, the material and both together. The container weight is the Tare weight, the material is called the Net weight and the container and the material together are called the Gross weight. The Net weight is displayed on the readout.

FEATURES
  • RS232 port
  • Auxiliary display port
  • GLP protocol
  • Selectable 5 language display text
  • Selectable displayed information settings
  • Selectable environmental filters
  • Selectable auto-print settings
  • Integral weigh below hook
  • Contrast and brightness control
  • Protective in-use cover

SPECIFICATIONS
Cat. No. w/o AutoCal™
EP64
EP114
EP214
EP214D*
Cat. No. w/AutoCal™
EP64C
EP114C
EP214C
EP214DC*
Capacity
62g
110g
210g
100/210g
Readability
0.1mg
0.1/1mg
Readability (std dev.)
0.1mg
0.1/0.5mg
Linearity
±0.2mg
±0.2/0.5mg
Weighing Units
Gram, Milligram, ounces, ounce troy, carat, pennyweight, Hing Kong Tael, Singapore Tael, Taiwan Tael, mommes, grain, tical, Newton, custom
Application Modes
Weighing, parts counting, animal/dynamic weighing, checkweighing, percent weighing, filling, gross/net/tare weighing
Tare Range
Full capacity by substraction
Stabilization Time
4 seconds
Operating Temp. Range
50-86ºF (10-30ºC) - without AutoCal™
50-104ºF (10-40ºC) - with AutoCal™
Power Requirements
100-120VAC, 220-240 VAC, 50/60Hz
Calibration
External/Internal
Display Type
High resolution LCD dot matrix w/backlight
Pan Size
3.5 in. (9 cm)
Dimensions (WxHxD)
8.3 x 13.8 x 13.8 in. (21 x 35 x 35 cm)
Net Weight
13.2lb (6kg)
* Moveable FineRange™

OTHER BALANCES FROM THE EXPLORER PRO SERIES
Explorer Pro Precision Balances
Explorer Pro High-Capacity Balances