Fluorescence Detector
| FEATURES |
|
Fluorescence techniques are particularly useful in the analysis,
by liquid chromatography, of amino acids; DNA, including fragments; enzymes
(NAD/NADH); environmental testing (water analysis); pesticides and herbicides;
proteins; fermentation processes (sugars); vitamins, steroids, various
drug metabolites; and many more compounds particularly in the biotechnology
area. For all these applications the sensitivity and specificity of the DFL-10
makes it an ideal detector for the analysis.
Sensitivity
D-Stars new flowcell arrangement for the DFL-10 uses a unique excitation
and emission geometry. It also minimizes stray light entering into the analysis.
Photomultiplier detection provides highly sensitive detection at very low light
levels. A completely enclosed optical compartment and a thermally stabilized
system enable the instrument to provide detection levels required in fluorescence
assays.
Quantitative analytical data can be obtained for many varied fluorescence applications with the DFL-10. The sensitivity of the DFL-10 is enhanced by the selection of precision excitation and emission filters. The correct filter selection offers greater specificity and adds to the analytical accuracy of the assay. The excitation filter is usually a narrow band (N) filter that should be selected as close as possible to the maximum excitation wavelength of the compound under analysis.
The emission filter is typically a Cut-On (C) filter
with a wavelength value that is approximately 10nm less than the maximum emission
wavelength
for the molecule. Cut-On filters pass all wavelengths of light greater
than the Cut-On wavelength value.
| Lamps | Prefocused mercury (254, 285 and 365nm), tungsten, and deuterium; user replaceable |
| Wavelength | Changeable excitation and emission filters |
| Spectral bandwidth | Dependent on chosen filters |
| Flowcells | Analytical-10µL, 250 psi max.; PEEK construction |
| Drift | < 1mV/hr at the analog data acquisition output After a 15 minute warm up |
| Linearity | Better than 2% |
| Recorder output | User selectable in 12 ranges, in three steps/decade, for a 10mV chart recorder |
| Analog output | +3.OV maximum, with a resolution of 10µV at the data acquisition output |
| Front panel controls | Recorder range, event mark, autozero, rise time, lamp on/off, display toggle |
| Front panel display | Large LED for fluorescence, lamp energy, high voltage, offset; indicators for recorder range rise time, lamp on/off, lamp type, and lamp error |
| Remote control | Autozero, lamp on/off, event mark, recorder range |
| Remote monitoring | Lamp energy, baseline offset (autozero correction) |
| Ambient env. | 4° to 40° C; 5% to 95% relative humidity; noncondensing |
| Power requirements | 115VAC, 220-230VAC, 50/60 Hz 100W |
| Size | 234 (W) x 381 (D) x 190 (H) mm; 9.2" x 15" x 7.5"; 18lbs. |
Once you have selected the base configuration, select the appropriate
lamp, excitation, and emission filters. The lamp, excitation and emission filters
are ordered separately and not included in the base price.
| CAT. NO. | DESCRIPTION |
| Fluorescence Detectors | |
| DFL-10 | Detector, 300-660nm, analytical flow cell |
| DFL-10E | Detector, 185-870nm, analytical flow cell |
| Lamp Assembly:* | |
| 025-0153 | 254nm pre-aligned Hg lamp assembly |
| 025-0154 | 285nm pre-aligned Hg lamp assembly |
| 025-0155 | 365nm pre-aligned Hg lamp assembly |
| 025-0076 | Pre-aligned Tungsten lamp assembly |
| 025-0078 | Pre-aligned Deuterium lamp assembly |
| Excitation Filters:* | |
| 023-254N | 254nm, 10nm Half Band Width (HBW), 12.5mm diameter, (N=narrow band) |
| 023-280B | 280nm, 10nm HBW, 12.5mm diameter, (B=broad band) |
| 023-280N | 280nm, 10nm HBW, 12.5mm diameter |
| 023-365N | 365nm, 10nm HBW, 12.5mm diameter |
| 023-405N | 405nm, 10nm HBW, 12.5mm diameter |
| 023-440N | 440nm, 10nm HBW, 12.5mm diameter |
| 023-492N | 492nm, 10nm HBW, 12.5mm diameter |
| Emission Filters:* | |
| 024-420C | 420nm cut on 25mm diameter |
| 024-435C | 435nm cut on 25mm diameter |
| 024-455C | 455nm cut on 25mm diameter |
| 024-515C | 515nm cut on 25mm diameter |
| 024-590C | 590nm cut on 25mm diameter |
| 024-665C | 665nm cut on 25mm diameter |
| *The prices of the lamps and filters are not included in the base instrument price. You must select the lamp and the excitation and emission filters separately. | |