GENEQ > Materials testing > Digital Displays
| F-Series Digital Display for Flow, Level, Pressure |
|
|
|
||||||||
|
|||||||||
|
|||||||||
| Product overview | |||||||||||||||||||||||||||||||||
| Flowrate / Totalisers | Flowcomputers | Batch Controllers / Dispensers | Level indicators | Temperature | Pressure Indicators | ||||||||||||||||||||||||||||
|
linearisation
|
hi/lo alarms
|
ratio
|
differential / sum
|
hi/lo alarms
|
linearisation
|
hi/lo alarms
|
hi/lo alarms
|
||||||||||||||||||||||||||
|
F010
|
F011
|
F012
|
F014
|
F110
|
F111
|
F115
|
F016
|
F112
|
F118
|
F013
|
F113
|
F126-EL
|
F126-EG
|
F114
|
F116
|
F127-EL
|
F030
|
F130
|
F131
|
F133
|
F136
|
F070
|
F073
|
F170
|
F077
|
F173
|
F040
|
F043
|
F143
|
F050
|
F151
|
F053
|
|
|
with pulse output
|
with pulse output
|
flowrate monitoring max. 4 alarm output
|
consumption / sum calculation
|
2 control / pulse + analog output
|
with one alarm output
|
temperature indicator
|
dual presure indicator
|
||||||||||||||||||||||||||
|
Flowrate / totalizer
|
bi directional measurement
|
flowrate monitoring one alarm output
|
ratio calculation and monitoring
|
two control or pulse outputs
|
level indicator
|
analog + maximum 4 alarm outputs
|
pressure indicator
|
||||||||||||||||||||||||||
|
Totalizer
|
2 signal inputs; 2 pulse output
|
analog + pulse output two flowrate
alarms
|
flow + temp. + press. for gas volume
calc.
|
with one control output
|
2 control / pulse + analog output
|
one alarm output
|
analog + maximum 4 alarm outputs
|
||||||||||||||||||||||||||
|
flowrate indicator
|
pulse and analog output
|
pulse and analog outputs
|
flow + temperature for liquid volume
calc.
|
consumption calc. with temp. correction
|
dispenser
|
analog + maximum 4 alarm outputs
|
with one alarm output
|
with one alar output
|
|||||||||||||||||||||||||
| Pulse input; type P |
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
|
|
|
|
|
|
|
|
|
|
|
| (0)4 - 20 mA input; type A |
X
|
X
|
X
|
X
|
X
|
X
|
|
|
X
|
X
|
X
|
X
|
X
|
X
|
|
X
|
|
X
|
X
|
X
|
|
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
| 0 - 10V DC input; type U |
X
|
X
|
X
|
X
|
X
|
X
|
|
|
X
|
X
|
X
|
X
|
X
|
X
|
|
X
|
|
X
|
X
|
X
|
|
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
| PT100; type T |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X
|
X
|
X
|
|
|
|
| Actual flowrate |
X
|
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
|
|
X
|
X
|
X
|
|
|
|
|
|
|
|
|
|
|
|
| Actual total (resettable) |
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
|
|
|
|
|
|
|
|
|
|
|
| Accumulated total |
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
|
|
|
|
|
|
|
|
|
|
|
| Preset and actual value |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X
|
X
|
X
|
|
X
|
|
|
|
|
|
|
|
|
|
|
|
| Actual level and percentage |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X
|
X
|
X
|
X
|
X
|
|
|
|
|
|
|
| Actual Temprature |
|
|
|
|
|
|
|
|
|
|
|
|
X
|
X
|
|
|
X
|
|
|
|
|
|
|
|
|
|
|
X
|
X
|
X
|
|
|
|
| Actual pressure |
|
|
|
|
|
|
|
|
|
|
|
|
|
X
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X
|
X
|
X
|
| 5 point linearisation |
|
|
|
|
|
|
|
X
|
X
|
X
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X
|
X
|
|
|
|
|
|
|
| (0)4 - 20mA / 0 - 10V output: |
|
||||||||||||||||||||||||||||||||
| - acc. to flowrate, level or temp. |
|
|
|
|
X
|
|
X
|
|
X
|
X
|
|
X
|
X
|
X
|
|
|
|
|
|
X
|
|
|
|
|
X
|
|
X
|
|
|
X
|
|
|
|
| - acc. to differential / sum |
X / XX / -
|
||||||||||||||||||||||||||||||||
| - acc. to ratio |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| - acc. to process stage |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X
|
|
|
|
|
|
|
|
|
|
|
|
| Pulse output acc. to total |
|
|
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
|
X
|
|
|
|
X
|
|
|
X
|
X
|
|
X
|
|
|
|
|
|
|
|
|
|
|
|
| High / low alarms |
|
|
|
|
|
|
|
|
|
X
|
X
|
X
|
|
|
X
|
|
|
|
|
|
|
|
|
X
|
X
|
X
|
X
|
|
X
|
X
|
|
|
X
|
| 1 stage control output |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X
|
X
|
X
|
X
|
X
|
|
|
|
|
|
|
|
|
|
|
|
| 2 stage control output |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X
|
X
|
|
X
|
|
|
|
|
|
|
|
|
|
|
|
| Overrun correction |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X
|
X
|
X
|
|
X
|
|
|
|
|
|
|
|
|
|
|
|
| Detection flow direction |
|
|
|
|
|
|
X
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Temperature compensation |
|
|
|
|
|
|
|
|
|
|
|
|
X
|
X
|
|
|
X
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Pressure compensation |
|
|
|
|
|
|
|
|
|
|
|
|
|
X
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Dual input unit |
|
|
|
|
|
X
|
X
|
|
|
|
|
|
|
|
X
|
X
|
X
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X
|
|
| Consumption calculation |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X
|
X
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Sum calculation (add on) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| External reset total or start / stop |
|
|
|
|
X
|
|
|
|
X
|
|
|
X
|
|
|
|
|
|
|
|
|
X
|
|
|
|
|
|
|
|
|
|
|
|
|
| RS232 / RS485 / TTL |
|
|
|
|
X
|
X
|
X
|
|
X
|
X
|
|
X
|
X
|
X
|
X
|
X
|
X
|
|
X
|
X
|
X
|
X
|
|
|
X
|
X
|
X
|
|
|
X
|
|
X
|
|
| Intrinsically Sage |
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
| Explosion proof |
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
| LED backlight |
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
X
|
| Terminal Connections | |
|
internal battery or loop powered, 12 / 24 V AC / DC
115 / 230V AC |
|
| Typical inputs: | |
| Turbine flometer PD-flowmeter positive displacement Magnetic inductive floweter Coriolis massflowmeter Vortex flowmeter Ultrasonic flowmeter Massflowmeter Level Pressure Temperature |
coil |