GENEQ > Environment > Turbidity Meters
| Datalogger |
| Model GL500-2-1 |
| Dataloggers and recorders with serial RS232 or USB connections |
|
FEATURES |
| Rugged and easy to use
|
|
Datalogger Product Description |
The GL500-2-1 Datalogger
is the latest addition to Global Water’s line of rugged remote dataloggers.
The dataloggers feature two analog channels and one digital channel for
recording data, as well as monitoring battery voltage. The datalogger
records over 81,000 readings and has four unique recording options: fast
(10 samples per second), programmable interval (1 second to multiple years),
logarithmic, and exception. Start and stop alarm times can be programmed
to synchronize multiple dataloggers, delay sampling until a preset time,
or limit the number of recordings during a day. The dataloggers are available
for computers with either a RS-232 serial communications port (GL500S-2-1
version) or a USB port (GL500U-2-1 version). |
Remote
Monitoring |
| The GL500-2-1 dataloggers can monitor two 4-20mA sensors (0-5 volt inputs are available as a factory option) and features a scalable digital input that accepts switch closure signals from rain gauges or relays, as well as pulses from various external monitoring and control devices. The datalogger provides switched power to the sensors based on the programmable sample interval and sensor warm up time settings. 2-wire and 3-wire sensors can be quickly connected to the datalogger’s internal terminal strip and calibrated via the Global Logger software. The GL500S-2-1 Datalogger Serial Communications version can be accessed through dial-out to a remote modem attached to the serial communication port. |
Software
|
| The GL500-2-1 dataloggers include Global Logger II Windows software and PDA software, which allow for easy setup, calibration, upload, and transfer to a spreadsheet program using a laptop, desktop, or PDA. The Global Logger II Windows software has online help files that are easily accessed using drop down menus and links to quickly find the answers to your questions. |
| Dataloggers Specifications Global Dataloggers |
| Memory:
Non-volatile flash memory Power: Voltage: Two 9VDC alkaline batteries standard. 8 VDC Min. to 24.0 VDC Absolute Maximum. Standby Current: 65uA Typical Logging Current: 5mA Typical + sensor current Analog Sensor Inputs: 4-20mA (0-5VDC as factory option) Resolution: 12-Bit, 4096 Steps Channels: 2 Input channels + battery voltage monitor Sensor Warm-up Time: Programmable, 0-15 Sec Digital Inputs: Switch closure or pulse input Maximum Input Voltage: 24VDC Maximum Frequency: 100Hz Minimum Pulse Width: 2mS Maximum Count: 65,535 (16-Bit) Sample Modes: Fixed Interval Programmable from 1 Sec. to >1 Year High Speed 10 Samples per second Logarithmic Sample Rate (Approximation) Exception (Log only on deviation from previous reading) Storage Capacity: 81,759 Recordings for all inputs plus time stamp Data Overwrite: Select memory wrap or unwrap (unwrap will stop logging data once memory is full) Communication Ports: GL500S-2-1: RS-232 4-pin circular connector GL500U-2-1: USB Type B Selectable Baud Rates: 9600, 19200, 28800, 38400, 57600, 115200 Clock: Synchronizes to the time and date of user's computer Clock Accuracy: 1 minute per month Operating Temperature: Industrial, -40ºC to +85ºC (Battery may not apply) Enclosure: PVC (3" x 3" x 3") Weight: 0.5 lbs Bluetooth Format: Bluetooth 2.0 SPP (Serial Port Protocol) Baud Rate: Auto Detect up to 115K Baud Power: 9 V Alkaline, approx. 20 hours continuous use Current: 30mA Average Range: 20 Feet Maximum Operating Temp: -40º to +185ºF (-40º to +85ºC) Compatible Software: Global Logger II version 2.1.5 or higher Global Logger II PDA software version 2.0.1 FL16 Flow Monitor version 2.3.2 |
Datalogger
Software |
| Compatible with Microsoft's
Windows 98, ME, 2000, NT, and XP |
| Datalogger Software Information |
| The Datalogger includes Global Water
Datalogger Software, Windows-based software that provides many useful
features, such as real-time readout, measurement interval and engineering
unit selection, station ID setting, and sensor calibration. The software
makes accessing recorded data and setting options easy. Data downloaded
from the datalogger can easily be opened in any PC spreadsheet program
for analysis and graphic presentation. Globlal Water's Datalogger Software
will run on a PC-type laptop or desktop computer running Windows 98 or
later. To communicate with the Datalogger, a standard RS232 serial cable
for the GL500S-2-1or a USB Type B cable for the GL500U-2-1 is required.
Purchase of the datalogger includes the appropriate communication cable
(for communication between the datalogger and your computer). |
| Datalogger Options |
| GL500U-2-1 Datalogger |
| USB version for collecting data with most laptop/desktop computers. Features 2 analog channels and 1 pulse channel. Includes two internal 9V batteries, Windows-based Global Water Datalogger Software, and PDA software for the CE and Mobile operating systems. |
| GL500S-2-1 Datalogger |
| SERIAL version for collecting data with most PDAs that use the CE and Mobile operating systems. Features 2 analog channels and 1 pulse channel. Includes two internal 9V batteries, Windows-based Global Water Datalogger Software, and PDA software for the CE and Mobile operating systems. |
| GL450-2-1 Optional Datalogger Enclosure Upgrade | |
| GL450-2-1 Optional
Datalogger Enclosure Upgrade Rugged weather-resistant enclosure for the Datalogger for addtional protection. NOTE: No additional batteries included. |
![]() |
| GL450-2-1-B Optional Datalogger Enclosure Upgrade Rugged weather-resistant enclosure for the Datalogger for addtional protection. NOTE: Includes 2.2AH battery. |
|
| Deluxe PDA Package | |
| Handheld PDA download package for GL500 Dataloggers. Standard PDA can read data from 23 full dataloggers before running out of memory. NOTE: PDAs WILL NOT INTERFACE WITH GLOBAL WATER DATALOGGERS WITHOUT A CUSTOM SERIAL CABLE (Serial cable is included with this package.) | ![]() |
| OTHER REMOTE MONITORING INSTRUMENT | |
|
|
|
![]() |
|
![]() |