Our new line of industrial controllers offers a wide range of features and functions such as single and dual setpoints, ON/OFF, proportional and PID control, relay outputs, user-selectable zoom, bidirectional isolated RS485, isolated recorder outputs in mAmps and volts, differential input, control through analog output and Fail Safe Features.

Simple-to-use
The large, dual-level LCD shows both pH (mV) and temperature and guides operators through calibration and programming with step-by-step prompts. The choice of ON/OFF, proportional and PID control provides extra versatility and makes it possible to pick the process controller that best fits your application. Keeping track of multiple controllers in different plants is made easy. These advanced controllers can be identified with both a factory and a process ID.

Save Money with Custom Programs
The new HI 21 and HI 22 help to prevent overdosing or costly system failures. You can set your high and low setpoint hysteresis bands independently to fine tune dosing processes with the ON/OFF controllers. Similarly, the proportional band and time period are userprogrammable to save on slow reacting chemicals which are commonly overdosed.

All models offer an adjustable timer from 10 minutes to 7 days as the maximum time that the relay contacts may remain closed, an important feature in case of sudden chemical depletion, truncated intake or discharge tubing and other calamities. With these silicon guardians, users can rest assured that processes are operating efficiently and safely.

Fail-Safe Protection The Fail-Safe alarms protect processes against critical errors arising from power interruptions, surges and human errors. The sophisticated yet easy-to-use system resolves these problems on two fronts: hardware and software. To eliminate blackout and line failure problems, the alarm function operates in a “Normally Closed” state and goes off if the wires are accidentally tripped, or when the power is down. This is an important feature since with many meters the alarm terminals close in abnormal situations, but no alarm is sounded with a line interruption, causing extensive damage. With our controllers, software is employed to set off the alarm in abnormal circumstances. For example, if the dosing terminals are closed too long (as with line interruption), red LED’s will also provide a visual warning signal.

Control through Analog Output
The HI 21 and HI 22 series include models that provide control through analog output. Now any compatible device such as electrovalves or pumps may be driven with these advanced controllers.

Differential Input
All Hanna controllers in this family now come with a differential input to prevent problems due to ground loop current. With this new feature, the life of the electrodes will be greatly extended.

PID Control
HI 21 and HI 22 can be configured with P, PI or PID controlling. This feature allows the user to set the controller according to the needs of the application, ensuring the best system performance in terms of steady state error and response time to changes.

Password Protection
Hanna’s password protection feature keeps these controllers safe from tampering. Only users with the proper password can change the settings of these hi-tech controllers.

Features
  • Computer compatibility
  • Alarm relay
  • ON/OFF, proportional & PID control
  • Automatic Temperature Compensation
  • Rugged, fiber-reinforced, ABS housing.

HI 21 Advanced pH Controller
HI 21 controllers are simple-to-operate, microprocessor-based process meters packed with features. For more flexibility and better resolution for chart recorders, any two points between 0 and 14 pH can be chosen to correspond to the analog output spans. Some HI 21 models are equipped with a bi-directional RS485 port. Push-button password programming prevents tampering. The microprocessor memory is fully programmable and has 3 months backup power supply. The Fail-Safe Alarm system protects the HI 21 against the pitfalls of process control, like power interruption or line failure. With HI 21 quick 1, 2 or 3 point calibration at pH 4.01, 7.01 and 10.01 comes standard. The temperature can be manually or automatically compensated for. Models with RS485 output allow computer compatibility, a necessity for process control instrumentation. You can also choose from ON/OFF, Proportional and PID control to save on chemicals.
Specifications

HI 22 Advanced ORP Controller
HI 22 controllers have been engineered with the same outstanding features as the HI 21 meters. The microprocessor memory is fully programmable and has a 3-month backup power supply. The Fail-Safe Alarm system protects these meters against the pitfalls of process control. User-selectable timing capability safeguards against overdosing and saves money while protecting the environment. These instruments have a differential input, extending electrode life by eliminating ground loop current through the reference. Users can choose between ON/OFF and Proportional control as well as selectable current and voltage outputs. For more flexibility and better resolution for chart recorders, choose any two points between 0 and 2000 mV to correspond to the analog output spans. An RS485 port makes one model PC compatible. Wiring the controllers is simple with extractable terminal modules. A host of self-testing features and user-friendly functions make HI 22 a great value.
Specifications

HI 23 Advanced EC Controller
HI 23 is a new series of wall-mounted, microprocessor conductivity controllers. Thanks to the 4-ring EC probe and automatic temperature compensation feature, these meters can provide very accurate measurements. You can choose among models featuring ON/OFF or PID control, analog input and output, double set point. The relay contacts can drive external devices as, for example, pumps or electro-valves. The input signal can come from a probe or a 4-20 mA transmitter. Models with RS485 output are also available. This option allows the user to insert the controller into a 2-wire RS485 network.
Specifications

Order Informations
Cat. No. Description
HI 21111 pH Controller with single setpoint, ON/OFF control and analog output.
HI 21211 pH Controller with dual setpoint, ON/OFF control and analog output
HI 21221 pH Controller with dual setpoint, proportional and ON/OFF control with analog output.
HI 21222 pH Controller with dual setpoint, proportional and ON/OFF control with RS485 output.
HI 21523 pH Controller with single setpoint, control through analog output, PID and ON/OFF control with analog and RS485 output.
HI 22111 ORP Controller with single setpoint, ON/OFF control and analog output.
HI 22122 ORP Controller with single setpoint, proportional and ON/OFF control and RS485 output.
HI 23211 EC controller with dual setpoint, ON/OFF control and analog output
HI 23212 EC controller with dual setpoint, ON/OFF control and RS 485 port
HI 23221 EC controller with dual setpoint, ON/OFF and PID control, and analog output
HI 23222 EC controller with dual setpoint, ON/OFF and PID control, and RS 485 port