GENEQ > Environment > Conductivity

Conductivity/TDS/°C/NaCl Meter
Model HI9835


The HI 9835 combines the more important parameters you need for measuring conductivity. Now you can sample Electro-Conductivity (EC), Total Dissolved Solids (TDS), sodium chloride (NaCl) and temperature all at once. Hanna's probe design innovation uses 4 rings enhanced with platinum for greater stability while increasing the range of measurable concentrations and temperature. You can choose between automatic and manual temperature compensation to facilitate your operating requirements.

In addition, you can also select from a range of TDS factors from 0.40 to 0.80 and a range of temperature coefficients 0.00 to 6.00% for greater consistency and reproducibility. The housing is completely waterproof and built to survive the harsh conditions of field use. For extended time studies, this meter can be connected to the available 12 VDC power supply.


SPECIFICATIONS
 
EC
TDS
NaCl
Temp.
Range
(autoranging)
0.00 to 29.99 µS/cm
30.0 to 299.9 µS/cm
300 to 2999 µS/cm
3.00 to 29.99 mS/cm
30.0 to 200.0 mS/cm
Up to 500.0 mS/cm
0.00 to 14.99 ppm
15.0 to 149.9 ppm
150 to 1499 ppm
1.50 to 14.99 ppt
15.0 to 100.0 ppt
Up to 400.0 ppt
0.0 to 400.0%
0.0 to 60.0°C
Resolution
0.01 µS/cm (from 0.00 to 29.99 µS/cm)
0.1 µS/cm (from 30.0 to 299.9 µS/cm)
1 µS/cm (from 300 to 2999 µS/cm)
0.01 mS/cm (from 3.00 to 29.99 mS/cm)
0.1 mS/cm (over 30.0 mS/cm)
0.01 ppm (from 0.00 to 14.99 ppm)
0.1 ppm (from 15.0 to 149.9 ppm)
1 ppm (from 150 to 1499 ppm)
0.01 ppt (from 1.50 to 14.99 ppt)
0.1 ppt (over 15.0 ppt)
0.1%
0.1°C
Accuracy
±1% of reading ± (0.05 µS/cm or 1 digit, whichever is greater)
±1% of reading ± (0.03 ppm or 1 digit, whichever is greater)
±1% of reading
±0.4°C
Typical EMC Deviation
±1% of reading
±1% of reading
±1% of reading
±0.1°C
EC Calibration
1 point with 6 memorized buffers
NaCl Calibration
1 point with HI 7037 buffer (optional)
Temperature Calibration
2 points at 0 and 50°C (plus ±1°C adjustment)
Temperature Compensation
Automatic or manual from 0 to 60°C (can be disabled to measure actual conductivity)
Temperature Coefficient
0.00 to 6.00%/°C (for EC and TDS only) Default value is 1.90%/°C
TDS Factor
0.40 to 0.80 (default value is 0.50)
Probe
HI 76309 4-ring probe, K=1 nominal and built-in temperature sensor (included)
Auto Off
After 5 minutes (can be disabled)
Power Supply
4 x 1.5V AA alkaline type batteries (included), or 12VDC adapter
Environment
0 to 50°C; 100% RH
Dimensions
196 x 80 x 60 mm (7.7 x 3.1 x 2.4”)
Weight
500 g (18 oz)

CAT. NO. DESCRIPTION
HI9835 Supplied complete with HI 76309 4-ring conductivity probe with 1 m (3.3’) screened cable, 4 x 1.5V AA batteries and instruction manual in a rugged case.
HI 76309 Conductivity probe
HI 721317 Hard carrying case
HI 710005 110V to 12VDC adapter
HI 710006 220V to 12VDC adapter
HI 7030L 12880 µS/cm calibration solution (460 mL)
HI 7031L 1413 µS/cm calibration solution (460 mL)
HI 7033L 84 µS/cm calibration solution (460 mL)
HI 7037L NaCl calibration solution (460 mL)