- Four casting options - provide total
flexibility in gel casting, either directly
within the tank or externally when the tank is in use
- Combs - colour-coded and height-adjustable
- offer complete control over
loading volume and well depth to a
maximum 112-sample throughput
- Four comb positions - at 3.5cm intervals
along the tray for swift separation of
multiple samples
- Buffer recirculation ports - may be
connected to a peristaltic pump for
buffer recirculation during
electrophoresis to maintain buffer pH
and prevent ionic gradient
formation
- Coloured loading strips - for easy well
detection when loading
- Compact tank - reduces the buffer
volume required to cover the gel,
providing greater control over the voltage
gradient and run-time
- UV-transparent acrylic casting tray -
allows the user to image the gel without
risk of damage due to handling
- Side handles - for safe and easy
transportation around the laboratory
|
HU13-UT - silicone gaskets, lining the
HU13 casting tray, form a leak proof seal
against the inner walls of the running
chamber when the casting tray is turned
at 90° to the direction of electrophoresis
HU13-SS - 13cm long Scie-Plas Super-
Seals offer total versatility in casting,
allowing the gel length to be tailored to
each user’s personal requirements |
| Complete System |
Part No. |
| Midi horizontal gel unit with removable casting tray and
2 x 1mm thick, 16-sample combs, coloured loading strips and
buffer recirculation ports |
HU13 |
| Replacement Parts & Accessories |
| 1 x gel casting tray 12,8 x 13 cm |
HU13-UT |
| 2 x buffer recirculation ports |
HU-BRP |
| 2 x silicone casting gates |
HU13-SCG |
| 1 x silicone gasket, 1 metre |
HU-SG |
| 2 x Super-Seals |
HU13-SS |
| 12 x coloured loading strips |
HU13-CS |
| 1 x external casting unit for 3 gel casting trays |
HU13-CU |
| 1 x gel scoop |
HU13-GS |
| 2 x 0.2mm thick, platinum electrode wire |
PT-0.2 |
| 2 x 1 metre power leads with shrouded 4mm power
output connectors |
CABLE-4 |
| Part No. |
Thickness (mm) |
Sample Throughput |
Tooth Width (mm) |
Max. Spacing (mm) |
Sample Volume in a 5mm
Deep Well (μl) |
| HU13-C1-10 |
1 |
10 |
9,5 |
2.5 |
40 |
| HU13-C1-12MC |
1 |
12 |
8 |
2 |
35 |
| HU13-C1-16 |
1 |
16 |
5.5 |
2 |
25 |
| HU13-C1-20 |
1 |
20 |
4 |
2 |
17 |
| HU13-C1-24 |
1 |
24 |
3 |
2 |
13 |
| *HU13-C1-28MC |
1 |
28 |
3 |
1.5 |
13 |
| HU13-C1.5-10 |
1.5 |
10 |
9.5 |
2.5 |
60 |
| HU13-C1.5-12MC |
1.5 |
12 |
8 |
2 |
50 |
| HU13-C1.5-16 |
1.5 |
16 |
5.5 |
2 |
35 |
| HU13-C1.5-20 |
1.5 |
20 |
4 |
2 |
25 |
| HU13-C1.5-24 |
1.5 |
24 |
3 |
2 |
20 |
| *HU13-C1.5-28MC |
1.5 |
28 |
3 |
1.5 |
20 |
| HU13-C2-10 |
2 |
8 |
9.5 |
2.5 |
80 |
| HU13-C2-12MC |
2 |
12 |
8 |
2 |
70 |
| HU13-C2-16 |
2 |
16 |
5.5 |
2 |
50 |
| HU13-C2-20 |
2 |
20 |
4 |
2 |
35 |
| HU13-C2-24 |
2 |
24 |
3 |
2 |
25 |
| *HU13-C2-28MC |
2 |
28 |
3 |
1.5 |
25 |
| *Multi-channel pipette compatible |