GENEQ > Environnement > Air - Qualité

Instrument de mesure de la qualité de l'air intérieur
modèles IAQ-Calc 7515, 7525, 7535 et 7545



Model 7545
Features and Benefits
• Low-drift NDIR CO2 sensor for stable, accurate readings
• Sampling function records multiple point measurements
• Ergonomic, overmolded case design

Models 7525 and 7545
• Temperature and relative humidity measurements help determine thermal comfort
• Calculates % outside air from either CO2 or temperature
• Directly calculates dew point and wet bulb temperatures
• Electrochemical sensor measures CO (Model 7545)
• Models 7525 and 7545 shows up to three parameters
• Models 7515 and 7535 shows only one parameter

TSI’s IAQ-CALC Meters are outstanding instruments for investigating and monitoring indoor air quality (IAQ). The Model 7515 is a cost-effective meter for carbon dioxide (CO2) measurements. The Model 7535 adds data logging of CO2.
The Models 7525 and 7545 simultaneously measure and data log multiple parameters. The Model 7525 measures CO2, temperature, humidity, and calculates dew point, wet bulb temperature, and % outside air. The Model 7545 adds carbon monoxide (CO).

Applications
• Verify building HVAC system performance
• Examine building IAQ conditions to optimize worker productivity
• Comply with regulations and guidelines


Specifications
IAQ-CALCTM
Models 7515, 7525, 7535, 7545
CO2
Sensor Type Dual-wavelength NDIR
(non-dispersive infrared)
Range 0 to 5000 ppm
Accuracy1 ±3.0% of reading or ±50 ppm,
whichever is greater
Resolution 1 ppm
Response Time 20 seconds
Temperature (Models 7525 and 7545)
Sensor Type Thermistor
Range 32 to 140°F (0 to 60°C)
Accuracy ±1.0°F (±0.6°C)
Resolution 0.1°F (0.1°C)
Response Time 30 seconds (90% of final value, air
velocity at 400 ft/min [2 m/s])
Relative Humidity (Models 7525 and 7545)
Sensor Type Thin-film capacitive
Range 5% to 95% RH
Accuracy3 0.1% RH
Resolution 0.1% RH
Response Time 20 seconds (for 63% of final value)
% Outside Air (Models 7525 and 7545) 
Range 0 to 100%
Resolution 0.1%
CO (Model 7545 only) 
Sensor Type Electro-chemical
Range 0 to 500 ppm
Accuracy ±3.0% of reading or ±3 ppm, which is greater
Resolution 0.1 ppm
Response Time <60 seconds to 90% step change
Operating Temperature 
32 to 113°F (0 to 45°C)
Storage Temperature
-4 to 158°F (-20 to 70°C)
Logging Capability (Models 7525 and 7545) 
Ranges Model 7525 logs up to 24,200 data points with all measured parameters enabled Model 7535 logs up to 40,300 data points with all measured parameters enabled Model 7545 logs up to 22,000 data points with all measured parameters enabled
Time Constant 1 sec, 5 sec, 10 sec, 20 sec, 30 sec (user selectable)
Log Intervals 1 second up to I hour (user selectable)
Meter Dimensions (all models) 
4.2 in. x 7.2 in. x 1.5 in. (107 mm x 183 mm x 38 mm) 
Probe Dimensions (Model 7515)
Length 2.7 in. (69 cm)
Diameter 0.76 in. (2.0 cm)
Probe Dimensions (Models 7525, 7535, and 7545)
Length 5.9 in. (15.1 cm)
Diameter 0.74 in. (1.9 cm)
Weight (with batteries)
Models 7515 and 7535 0.6 lbs (0.27 kg)
Models 7524 and 7545 1.16 lbs (0.53 kg)
Power Requirements 
Model 7515 Four AA-size batteries
Models 7525, 7535, and 7545 Four AA-size batteries or AC adapter
• 1 At 77°F (25°C). Add uncertainty of ±0.2%/°F (±0.36%/°C) away from calibrated temperature.
• 2 For range of 23 to 203°F (-5 to 95°C).
• 3 At 77°F (25°C). Add uncertainty of ±0.03% RH/°F (±0.05% RH/°C) away from calibrated temperature.

Data Logging-Models 7525, 7535, and 7545
• Simultaneously records all parameters and logs samples with time and date stamp
– Model 7525 logs up to 24,200 data points with all measured parameters enabled
– Model 7535 logs up to 40,300 data points with all measured parameters enabled
– Model 7545 logs up to 22,000 data points with all measured parameters enabled
• TSI LogDat2TM software permits easy transfer of data to a computer
• Data can be reviewed on-screen, or downloaded to a computer for easy report generation
• Statistics function displays average, maximum and mini mumvalues, and the number of recorded samples

7515
7525
7535
7545
CO2
CO
Temperature
Humidity
% outside air
Dew point
Wet bulb temperature
Data logging/downloading
Statistics
Review data
Printer output
Calibration certificate