GENEQ > Environment > Water Level Measuring and Recording Instruments

Industrial Submersible Pressure Transducer
Series 700, 710, 720, 730

  
FEATURES
  • High Static Accuracy & Repeatability
  • Welded 316SS Construction
  • Small Rugged Package
  • User-Specified Pressure Ranges Available
  • 100% Computer-Tested, Calibrated and Serialized
  • Unique Cable Seal System
  • Fully Temperature Compensated
  • Datalogger Compatible

  • APPLICATIONS
  • Well Monitoring
  • Slug Tests
  • Pump Control
  • Ground Water Monitoring
  • Soil Remediation
  • Oceanographic Research
  • Lift Stations
  • Level Control
  • Surface Water Monitoring
  • The Series 700 family of submersible pressure transducers is specifically designed to meet the rigorous environments encountered in liquid level measurement and control. It can be configured to perform to specifications under the most adverse, reactive conditions.

    These transducers incorporate the latest advancements in piezoresistive pressure sensing technology. A stability-enhancing charged "Field Shield" is vapor deposited directly to the pressure cell. A welded 316 Stainless Steel diaphragm, with a spring rate ratio of 1000:1 with the piezoresistive pressure cell, is used for contact with the media. The transducer housing is an all-welded design, constructed of corrosion resistant 316 SST. Titanium housing with hastelloy/platinum sensor combination is offered for extremely corrosive media.

    The Series 700 also features state-of-the-art, surface mount internal signal conditioning which provides a power supply rejection of 0.001% and either a 4-20 mAdc, 0-5 Vdc, or mVdc process signal. Approvals to FM, CSA, and UL are available for Class I, Div 1, Groups A, B, C and D, and Class II, Div 1, Groups E, F and G, and Class III, Div 1 hazardous locations. These instruments also meet CE approval according to EN-50081-2 and EN-50082-2. Hazardous locations installation must be to local and national electrical codes and installed with an approved electrical barrier, such as manufactured by R.G. Stahl, Inc.

    Each transducer is shipped with a barrier that prevents moisture from entering the cable vent tube and with a traceable calibration card. The card specifies input/output conditions and actual data recorded during manufacture. Optional calibration is available when additional performance characteristics are required. All units are repairable and have low power requirements.

    SPECIFICATIONS
    730..... 720..... 710..... 700 Units Comments
    Pressure Ranges
    Pressure Ranges 0-5 through 0-300
    0-35 through 0-21000
    psi
    kPa
    any intermediate ranges available
    Proof Pressure 1.5 x F.S.  
    Burst Pressure 2.0 x F.S.  
    STATIC Performance
    Static Accuracy ±0.10...±0.25...±0.50...±1.00 %FSO
    BFSL
     
    Thermal Error ±0.05............................±0.10 %FSO/°C worst case
    Resolution Infinitesimal    
    Environmental
    Wetted Materials 316 SS, Fluorocarbon   options available
    Compensated Temp Range 0 to 50........................10 to 30 °C options available
    Operating Temp Range -10 to 60 °C options available
    Electrical
    Excitation 2.5 - 10
    5
    9 - 30
    VDC mVdc output (ratiometric)
    mVdc output (non-ratiometric)
    mAdc, Vdc output
    Input Current 3.5
    20
    mA max mVdc, Vdc output
    mAdc output
    Output 2.5 - 10
    0 - 100
    0 - 5
    4 - 20
    mV/V
    mV
    VDC
    mA
    ratiometric, depending on ranges
    non-ratiometric
    3 wire
    2 wire
    Zero Offset ±5
    ±60
    ±0.12
    mV
    mV
    mA
    mVdc output
    Vdc output
    mAdc output
    Output Impedance < 10 ohms  
    Insulation Resistamce 100 megaohms at 50 VDC
    Circuit Protection Polarity, surge/shorted output    
    Physical
    Dimensions 1.0" dia. X 4.02' long.    
    Weight 198 grams excluding cable
    Cable Polyurethane jacketed shielded cable with polyethylene vent tube. 90 kilograms pull strength. Conductors are 22 AWG. Tefzel jacket optional. 70 g/m specifiy cable length as separate line item
    Mounting Provisions Suspended by cable. For turbulent conditions, specify optional mount bracket or conduit fitting