GENEQ > Biotechnology > pH Meters - Lab
| Laboratory Benchtop pH Meters |
| Models pH 1100, pH 2100 and pH/Con 510 |
![]() |
![]() |
![]() |
|
Model pH 1100
|
Model pH 2100
|
Model pH/Con 510
|
Oakton instrument offers meters with
0.01 and 0.002pH accuracy, covering virtually all specification requirements.
More importantly, Oakton benchtop meters are easier to use with setup
and calibration prompts, built-in electrode diagnostics, and pull-out
instruction card on the meter. You cn rely on what you see and trust in
the results. Oakton benchtop pH meterss are built to last with three-year warranties. With our superior use of the latest in electronics technology including ASIC microprocessors and other high quality components, we offer trouble-free performance for years. In addition, our tolerance standards for our electrodes and temperature sensors are among the best in the industry, especially when it comes to having minimum offset, very low drift and good linearity. The result is good signal processing for exceptional dependability. Oakton instruments gies you the option to select economical meters with just a few extra handy features such as memory and recorder output, or to select highly versatile, feature-rich models. Our top-of-the-line models offer ion measurement with up to three digits of resolution, fully customized ion concentration readout, and dozens of pH and ion measurement features to ensure all your requirements are met. |
| FEATURES |
| Model pH 1100 |
|
| Model pH 2100 |
|
| Model pH/Con 510 |
|
| APPLICATIONS |
| Model pH 110 |
|
| Model pH 2100 |
|
| Model pH/Con 510 |
|
| SPECIFICATIONS | |||
|
Model
pH 1100 |
Model
pH 2100 |
Model
pH/Con 510 |
|
| Measuring Parameters |
pH, mV, rel mV, °C,
°F |
pH, mV, rel mV, °C,
°F |
pH, mV, conductivity, Total dissolved solids, °C, °F |
| pH | |||
| Range |
-2.000 to 16.000pH |
-2.000 to 16.000pH |
-2.00 to 16.00 pH |
| Resolution |
00.001/0.01 pH |
00.001/0.01 pH |
0.01 pH |
| Accuracy |
±0.002 pH |
±0.002 pH |
±0.001 pH |
| Calibration |
Five pointspoints (Choose
from USA: 1.68, 4.01, 7.00, 10.00, 12.45 or NIST: 1.68, 4.01, 6.86, 9.18,
12.45) |
Five pointspoints (Choose
from USA: 1.68, 4.01, 7.00, 10.00, 12.45 or NIST: 1.68, 4.01, 6.86, 9.18,
12.45) |
- |
| Millivolt | |||
| Range |
-1800 to +1800 mV |
-1800 to +1800
mV |
-600 to +600
mV |
| Resolution |
0.1mV |
0.1mV; 1 mV beyond |
0.1mV from ±199.9mV |
| Accuracy |
±0.2mV |
±0.2mV; 0.2mV beyond |
±0.2mV from ±199.9mV |
| Calibration |
Offset up to ±1800mV |
Offset up to ±1800mV |
- |
| Relative Millivolt |
Yes |
Yes |
- |
| Ion | |||
| Range |
- |
0.000 to 19900 ion concentration units |
- |
| Resolution |
- |
± least significant
digit |
- |
| Accuracy |
- |
±0.5% of reading |
- |
| Calibration |
- |
up to 5 customizable points |
- |
| Temperature | |||
| Range |
-5.0 to 105.0°C (23 to 221°F) |
-5.0 to 105.0°C (23 to 221°F) |
0.0 to 100.0°C (32.0 to 212.0°F) |
| Resolution |
0.1°C (0.1°F) |
0.1°C (0.1°F) |
0.1°C (0.1°F) |
| Accuracy |
±0.3°C ±0.5°F |
±0.3°C ±0.5°F |
±0.5°C ±0.5°F |
| Temp. Condensation |
Automatic or manual, 0
to 100°C |
Automatic or manual, 0
to 100°C |
Automatic or manual, 0
to 100°C |
| Special Meter Functions | |||
|
|
||
| Special Design Features | |||
|
|
|
|
|
| CAT. NO. | DESCRIPTION |
| Model pH 1100 | |
| OAWD-35620-20 | pH 1100 meter, with pH electrode and temperature probe |
| OAWD-35620-22 | pH 1100 meter, meter only |
| Model pH 2100 | |
| OAWD-35621-00 | pH 2100 meter with pH electrode and temperature probe |
| OAWD-35621-02 | pH 2100 meter |
| Model pH/Con 510 | |
| OAWD-35610-12 | pH/CON 510 benchtop meter only, 110/220 VAC |
| OAWD-35610-10 | pH/CON 510 benchtop meter, 110/220 VAC |