Geneq > Essais sur Matériaux > Béton > Béton Bitumineux

Nettoyeur à solvant LENIUM RV
 


For Extraction and Recovery of Asphalt Cement

Description
LENIUM RV is a stabilized normal Propyl Bromide (n-PB) formulation specially designed to remove contaminants such as bituminous cement, oils, and greases. The fluid has physical properties and solvency characteristics that are similar to chlorinated solvents such as 1,1,1-trichloroethane (TCA) and trichloroethylene (TCE).

LENIUM RV is an ideal replacement for 1,1,1-trichloroethane, trichloroethylene, and methylene chloride used in tests for Asphalt Content Extraction (ASTM D2172), Recovery of Extracted Binder (Abson-ASTM D1856; Rotavapor ASTM D5404), or combined extraction and recovery methods (AASHTO T 319-031).

Typical Properties

The physical and environmental properties of LENIUM RV are compared to other chlorinated solvents in Table 1.

Table 1

 

LENIUM RV Trichloroethylene Methylene
Chloride
1,1,1-TCA

Flash Point (TCC)

None None None None

Boiling Point

160°F (71°C) 189°F (87°C) 104°F (40°C) 165°F (74°C)

Specific Gravity @ 25°C

1.35 1.46 1.33 1.32

Viscosity @ 25°C

0.49 cp 0.54 cp 0.43 cp 0.79 cp

Surface Tension (dynes/cm)

25.9 26.4 28.2 25.6

Vapor Pressure @ 20°C

110.8 mm Hg 57.8 mm Hg 349 mm Hg 100 mm Hg

Evaporation Rate (TCA = 1)

0.96 0.57 1.64 1

Specific Heat @ 25°C

0.27 0.22 0.28 0.25

Heat of Vaporization

58.8 cal/g 57.2 cal/g 78.7 cal/g 57.5 cal/g

Solubility in Water

240 ppm 110 ppm 140 ppm 70 ppm

Solubility of Water

500 ppm 300 ppm 6 ppm 500 ppm

Flammability Limits (vol %)

4 ñ 7.8 8 ñ 10.5 14 ñ 22 7 ñ 13

Kauri Butanol (KB) Value

125 129 136 124

Atmospheric Lifetime

16 days <1 year <1 year 5 years

ACGIH TLV

25 ppm * 50 ppm 25 ppm 350 ppm

* manufacturer recommended


Environmental and Regulatory

Table 2

Ozone Depletion Potential (ODP)

0.013 – 0.018*

Global Warming Potential (GWP)

Zero

Volatile Organic Compound (VOC)

Yes

Significant New Alternatives Program (SNAP)

Pending

Hazardous Air Pollutants (HAP)

No

National Emission Standards for Hazardous Air Pollutants (NESHAP)

Not regulated

Superfund Amendments and Reauthorization Act (SARA)

Not regulated

Resource Conservation and Recovery Act (RCRA)

Not regulated

* Source: US EPA. ODP may be greater at locations near the equator.


Disposal
Petroferm recommends contacting your current or local environmental service company for disposal of this product. The most common and economical method of disposal is incineration of used material in compliance with all applicable government regulations. Used LENIUM RV can also be delivered to a solvent reclaimer.

Packaging
LENIUM RV is available in 5-gallon pails (55 lb) and 55-gallon drums (600 lb). Samples are available in one-quart containers upon request.

Storage
LENIUM RV should be stored in the original container, preferably in a cool, ventilated, fire-resistant building. Avoid overheating or freezing.

Shelf Life
The shelf life for this product is indefinite when it is stored in its original, sealed container at room temperature. However, the product should be inspected after the designated date on the product label (twenty-four months from the date of manufacture) prior to customer use.