- Study of pumps centrifuges/volumetric
- Conditions of use
- In load or aspiration
- Physical Characteristics of the pumps
- Maintenance of a pump
- Assembly, disassembling, replacements of parts
- Replacement of a trimming, a braid, a bearing, gears, a paddle…
- Wiring
- Wiring of electric components of power in cupboard
- Choice of components
- Regulation: - integration of a system of flow and level monitoring Intervention on group of filtration
- Replacement of filters
- Modification of the grid of filtration
|
- Structure
- out of aluminum anodized on casters with brake
- stainless vat partly low with drainage sluice
- Electric box n° 2:
- transparent cap
- contact of safety on opening of door
- support of platinum and connectors
- compatible for use of platinums of wiring or prewired proposed
- 1 platinum of direct starting
- Platinize prewired:
- 1 with integral direct starting
- 1 with progressive starting
- 1 with variator
- Description of the compatible equipment:
Positive-displacement pumps in cases drink
- 1 volumetric motor-driven pump group with mechanical trimming gears
- 1 positive-displacement pump in parts spare without constraints for activities of assembly mechanical disassembling/trimming
- 1 batch of defective parts and replacement for mechanical trimming positive-displacement pump
- Centrifugal pumps in cases drink
- 1 centrifugal motor-driven pump group with press packs
- 1 pump centrifuges without constraints in parts spare for activities of assembly disassembling/press packings
- 1 pump centrifuges without constraints in parts spare for activities of assembly mechanical disassembling/trimming
- 1 pump centrifuges with sealing by press packs for exchange of pump on motor-driven pump group and/or activities of various maintenances
- 1 pump centrifuges with sealing by mechanical trimming for exchange of the pump on motor-driven pump group and/or activities of various maintenances
- 1 batch of defective parts and replacement for pump centrifuges with mechanical trimming and press packs
- Hydraulic system:
- 2 cylindrical polyethylene tanks high density (ref. 5) (1 tank for pumping in load and the other for pumping in aspiration)
- Volume of each tank: 100 L
- System of draining and gauge of level
- Transparent Pipings PVC
- V1: Winnow flow with membrane
- V2, V3, V5: valves ¼ turn with spherical plug
- V4: valves ¼ turn with spherical plug bored for generation of pressure losses
- 1 float flowmeter
- 2 pressure gauges for measurement of pressures to the aspiration and repression Electric box n° 1:
- key lock for opening of the box
- disconnecting switch cadenassable
- circuit breaker and differential
- emergency stop with key
- button manufacture of order
- tachometric bill-poster
- selector of direction of walk
- ground lights
- Platinums of wiring (option)
- 1 for direct starting
- 1 for integral direct starting
- 1 for progressive starting
- 1 for variator
- Filtration (option):
- 2 filters cartouches
- 1 batch of cartouches to sampled calibration
- Control/instrumentation (option)
- 3 adjustable sensors of level usable indifferently on the 2 tanks
- 2 sensors reed/THEY on flowmeter
- 1 flowmeter at analogical exit
- 2 pressure gauges/pressure controller with 1 threshold with repression and the aspiration
- 2 pressure gauges with analogical exit
Also compatible: kits of vibratory analysis MBP011 and alignment MBP 021/to consult us |