| Multi-Parameter Water Quality Instrument |
| model MultiLine IDS from WTW |
![]() |
![]() |
| Description |
The new multi-parameter systems with intelligent, digital sensors for pH, dissolved oxygen and conductivity measurement revolutionize multi-parameter measurement: The MultiLine® meters are in a class of their own: |
| Specifications |
| One – Multi 3410 | |
![]() |
|
One measurement channel for different parameters: For those who need to measure mainly one parameter, but occasionally require a second or third. |
D.O. measurement (optical), Concentration |
0.00 … 20.00 mg/l |
D.O. measurement (optical), Saturation |
0.0 … 200.0 % |
D.O. measurement (optical), Partial pressure |
0 … 400.0 hPa |
D.O. measurement (optical), Temperature |
0.0 … 50.0 °C (32.0 ... 122.0 °F) |
pH |
– 2.0 … 20.0 pH – 2.00 … 20.00 pH – 2.000 … 20.000 pH |
mV |
± 2000 ± 1250.0 |
pH/mV, Temperature |
– 5.0 … 105.0 °C (23.0 ... 221.0 °F) |
Conductivity |
0.0 … 2000 mS/cm |
Conductivity, additionally |
0.00 … 19.99 µS/cm K = 0.1 cm–1 |
Conductivity, Spec. resistivity |
0.00 … 20 MΩ cm |
Conductivity, Salinity |
0.0 … 70.0 (acc. IOT) |
Conductivity, TDS |
0 … 1999 mg/l 0 … 199.9 g/l |
Conductivity, Temperature |
– 5.0 … 105.0 °C (23.0 ... 221.0 °F) |
| Two – Multi 3420 | |
![]() |
|
Two measurement channels: For simultaneous measurement with two similar or different sensors. |
D.O. measurement (optical), Concentration |
0.00 … 20.00 mg/l |
D.O. measurement (optical), Saturation |
0.0 … 200.0 % |
D.O. measurement (optical), Partial pressure |
0 … 400.0 hPa |
D.O. measurement (optical), Temperature |
0.0 … 50.0 °C (32.0 ... 122.0 °F) |
pH |
– 2.0 … 20.0 pH – 2.00 … 20.00 pH – 2.000 … 20.000 pH |
mV |
± 2000 ± 1250.0 |
pH/mV, Temperature |
– 5.0 … 105.0 °C (23.0 ... 221.0 °F) |
Conductivity |
0.0 … 2000 mS/cm |
Conductivity, additionally |
0.00 … 19.99 µS/cm K = 0.1 cm–1 |
Conductivity, Spec. resistivity |
0.00 … 20 MΩ cm |
Conductivity, Salinity |
0.0 … 70.0 (acc. IOT) |
Conductivity, TDS |
0 … 1999 mg/l 0 … 199.9 g/l |
Conductivity, Temperature |
– 5.0 … 105.0 °C (23.0 ... 221.0 °F) |
| Three – Multi 3430 | |
![]() |
|
Three measurement channels can be used in any combination for similar or different parameters: Simultaneous multi-measurement without compromise. |
D.O. measurement (optical), Concentration |
0.00 … 20.00 mg/l |
D.O. measurement (optical), Saturation |
0.0 … 200.0 % |
D.O. measurement (optical), Partial pressure |
0 … 400.0 hPa |
D.O. measurement (optical), Temperature |
0.0 … 50.0 °C (32.0 ... 122.0 °F) |
pH |
– 2.0 … 20.0 pH – 2.00 … 20.00 pH – 2.000 … 20.000 pH |
mV |
± 2000 ± 1250.0 |
pH/mV, Temperature |
– 5.0 … 105.0 °C (23.0 ... 221.0 °F) |
Conductivity |
0.0 … 2000 mS/cm |
Conductivity, additionally |
0.00 … 19.99 µS/cm K = 0.1 cm–1 |
Conductivity, Spec. resistivity |
0.00 … 20 MΩ cm |
Conductivity, Salinity |
0.0 … 70.0 (acc. IOT) |
Conductivity, TDS |
0 … 1999 mg/l 0 … 199.9 g/l |
Conductivity, Temperature |
– 5.0 … 105.0 °C (23.0 ... 221.0 °F) |