| Terminal de transmission de données à distance Neon 2002C - Satellite |
![]() |
![]() |
The NRT is a small self-contained unit which connects to sensors, records readings from them and transmits the data to a central server via satellite communications. |
|
| Features |
|
| Description |
| The NRT-Satellite is a small self-contained unit which connects to sensors in the field, collects readings from those sensors, and transmits the collected data to a central server via satellite communications. The Neon central server system is provided on a Neon Data Service basis and on a Neon Client System basis and provides a central computer system to monitor and receive data from many Neon NRT units in the field. The NRT Satellite is designed to automate collection of remote data from environmental monitoring, industrial measurements, and utility metering via the international Globalstar LEO Satellite network from any location on the globe, except the Arctic, Antarctica, and Africa. Fully bidirectional communications are possible via the Neon server. Data can be collected directly and the NRT programmed from any internet connection. The NRT supports integrated logging or automated collection of data from an external data logger. The NRT’s built-in modem supports packet data, switchboard circuit data, and SMS communications. Long battery life and low operating costs are made possible through use of advanced microcontroller technology and an efficient protocol that takes advantage of Globalstar’s packet transfer capability. |
| Specification |
| Physical specifications | |
| Material | Anodised aluminium |
| Size | 200mm H x 112mm W x 50mm D |
| Weight | 850 grams (including battery pack) |
| Operating temperature | -20 to 60 °C. Not affected by humidity |
| Antennae | External conical dielectric resonator 103mm D x 63mm H, 1m cable |
| Electrical specifications | |
| Battery | 10.8V 14Ah lithium (non-rechargeable) |
| External power | 10.5 to 16VDC input available if required |
| Instrument power | Continuous 3.6V nom (20mA max) plus 2.5V ref (5mA max) |
| I/O | 2 x analog inputs – 12 bit resolution 1 x counter input – 16 bit 3kHz or 3–5V DC signal 1 x control output 1 x HSIO (16 x 16 bit bi-directional, synchronous data) channel |
| Serial Comms | RS-232 (300 to 230,400 baud). |
| Integrated logger specifications | |
| Storage memory | 15,000 readings – non-volatile fl ash memory |
| Time clock | Crystal regulated, +/- 10 seconds/month – automatically network synchronised |
| Scan rates | Programmable from 1 second to 12 hours |
| Log intervals | Programmable from 1 second to 1 week |
| Storage memory | 15,000 readings – non-volatile fl ash memory |
| Operating modes | Terminal (internet enabled data logger interface for STARLOG compliant loggers) Scheduled (Continuously to weekly – daily is default) Integrated – fully programmable STARLOG compatible micrologger FTU – Field Test Unit via RS232 & IrDA for field support |
![]() |