GENEQ > Meteorology > Data Loggers

Data Logger for wind resource assessment
Nomad 2


The NOMAD 2 data logger offers advanced functionality and simplified installation while reducing system costs. With its advanced lowpower circuitry, real-time operating system, and Windows™-compatible Compact Flash Cards, NOMAD 2 collects and secures the data you need.
More Sensor Inputs
Connect up to 12 anemometers or other frequency or state devices to the NOMAD 2, including rain gauges, energy meters, and relays. Another 8 analog inputs connect directly to wind vanes, thermistors, and transducers measuring air pressure, electric power, sound level, or anything else that concerns you at your wind site. Get remarkable ±0.02% accuracy on counter inputs and ±0.2% accuracy on analog inputs. Connect most transducers and sensors with no need for extra modules.
Get Your Data Your Way
NOMAD 2 makes it easier than ever to get your data. Whether your connection is GSM, CDMA, AMPS cellular, or landline, NOMAD 2 will answer your call and send you e-mail. Robust Compact Flash Cards provide solid-state storage and can be read by any PC using off-the-shelf readers. NOMAD 2 comes with NOMAD Desktop™ software to check in on your logger and see real time values with the Zoom feature. Refine study parameters by uploading a new configuration to NOMAD 2 remotely - NOMAD Desktop's advanced database system will keep all your data organized and labeled.
Weatherproof
The NOMAD 2 data logger is designed to withstand the harshest of climates in its lockable steel shelter box. The wide-temperature display, batteries, and data cards allow the data logger to operate fully from -40° to 185°F (-40° to 85°C).
Field Friendly
We know field visits have to be made in the cold, wind, and snow. NOMAD 2's vacuum fluorescent display (VFD) option gives a clear bright readout in temperatures down to -40°C and in full sunshine. The LED ”heartbeat” provides assurance of normal operation independent of the display. The breakthrough integrated shelter box design uses innovative mini-rack mounting for power and communications components, so installations are easy to maintain. Fieldproven lightning protection circuitry is built in, reducing the number of connections to wire. Larger, color-coded cageclamp terminals make wiring faster and easier, even with gloves on. A built-in serial port lets you use NOMAD Desktop on site. No laptop? NOMAD 2's easy-to-use front panel and menuing system tells you everything you need to know. Reprogram the logger in seconds by uploading a configuration from your Compact Flash Card.
Smart Power Management
NOMAD 2 will run on two standard 9V alkaline batteries for six months. If that isn’t enough, add internal 12V batteries to run longer, even with your preferred transducers and remote communications gear. NOMAD 2 manages transducer power and sensor excitation to get the most out of whatever batteries you use. Add a solar package for perpetual operation. A built-in relay provides control for your needs, including sensor heating for icing conditions.
Specifications
Sensor Inputs
12 Counter Inputs:
• Configurable for AC & pulse anemometers, other frequencyoutput devices, and high/low digital or relay state signaling
• Frequency range DC to 2 kHz
• High display resolution with low frequency anemometers
• Input high/low threshold configurable for 0V or 3V
• Configurable filtering for low frequency devices
• 1-second count integration, ±0.02% accuracy
8 Analog Inputs:
• Configurable range of 0 to 2.5V or 5V
• 12-bit analog to digital conversion
• 1-second sampling, ±0.2% accuracy
• Direct interface to potentiometer wind vanes, 10k thermistors, and analog-output transducers
Fault Detection:
• Feedback input from 2.5V+ excitation output for wiring and device fault detection
Internal Temperature:
• 1-second sampling, ±2°C accuracy
Power Supplies:
• Measurement of two 9V batteries and 12V power
• 1-second sampling, ±0.1V accuracy
 
Outputs
2.5V+ Excitation:
• 2.5V+ smart-switched excitation distributed to all input terminal blocks for energy-conserving measurement of potentiometers and thermistors
• Calibrated to ±5mV, 25 ppm/°C, 250 mA max
12V Transducer Power:
• 12V+ smart-switched transducer power output distributed to all input terminal blocks for energy-conserving operation of electronic transducers
• 1 Amp maximum
12V Modem Power:
• 12V+ configurable switched modem power output for energy-conserving operation of cellular & other modems
• 1 Amp maximum
Relay Output:
• For de-icing or other control applications
• SPST dry contact, 1 Amp maximum, AC or DC
 
Power Supply
9 Volt Batteries:
• 2 parallel standard 9V batteries in sliding receptacles
• Up to 6 months operation with alkaline, up to one year with lithium (-40°C) batteries that have no shipping restrictions
12 Volt Power:
• 12V (10-18V DC) input for internal primary or rechargeable batteries, external DC power supply, or regulated solar panel
• Two-screw removable internal mounting for lead-acid batteries for higher power transducer, controls, and communication gear, standard sizes up to 14 AH, extreme environment sizes up to 8 AH
Solar:
• Optional on-board solar charging regulator/controller
 
Serial Ports
• 3 independent RS232C serial ports, up to 115 kBaud
Local Port:
• Direct straight-cable connection to laptop or PC
• Standard pinout DB9, DCE
Remote Port:
• Connects to modem, radio, or asynch network adapter
• Auto-wakeup Rx input
• Internally connected for SWI-supplied modem options
• Field-wireable terminals for customer-installed devices
Device Port:
• Connects to and logs from communicating transducers including multifunction Phaser® power transducers & ultrasonic anemometers
 
ESD Protection
• All inputs, outputs, and serial port signaling transient and fault protected
• No additional lightning protection needed
 
User Interface
Local Display:
• 4 x 20 alphanumeric character display, LCD or VFD
• Configurable smart-switched power
• Automatic temperature-compensating LCD contrast
Keypad:
• 7-key sealed membrane keypad
Remote Interface:
• Full display, configuration, data transfer, & firmware upgradability by local port or modem connection to any PC via NOMAD Desktop™
Status Light:
• Heartbeat LED indicates operational status independent of display
 
Input and Data Processing
Wind Speed:
• Slope & offset scaling, auto-zeroing for counter inputs
Wind Direction:
• Modulo 360° and true vector processing
• Deadband location correction
Temperature:
• Thermistor linearization to device accuracy (±0.1°C)
Math Functions:
• Average, standard deviation, maximum, time of maximum, minimum, time of minimum, total, sample value
Recording Intervals:
• 1 minute, 10 minutes, hourly, or daily in any combination for all inputs and math functions
 
Data Storage
Media:
• Industry/consumer standard Compact Flash, up to 256MB
• Read/write-able by any notebook or desktop PC via PCMCIA adapter or any USB-type Compact Flash adapter
• Full -40° to 85°C operation rated devices available
Formats:
• Card directory & file formats are fully Windows™ compatible
• Any FAT (PC) formatted Compact Flash Card fully usable
• Data written to daily files in named monthly subdirectories
• Each datum in standard IEEE floating point format, indexed for positive database ID independent of file name/location
• Each datum time-stamped in Universal Time (UT/GMT), configurable for time zone & daylight savings offsets
Transfer:
• Files transferable by card removal, local serial connection, remote dial-up connection, or as e-mail attachments
 
Physical
Operating Temp:
• -40° to 85°C all specifications (Vacuum Fluorescent Display)
LCD Temperature:
• LCD operates from -20° to 70°C, storage -30° to 80°C
Internal RT Clock:
• ±1 minute/month accuracy, internet time-server adjustable
• Backed up by socketed 2032 Lithium coin cell (10 year life)
Wire & Cabling:
• 12 six-screw, 0.2" (5mm) cage clamp style terminal blocks
• Signal, ground, excitation, switched & unswitched 12V power distributed to each of 8 terminal blocks
• Standard SMA-F bulkhead connector for external antennas
• Four 3/4" npt/pg21 knockouts for cable & conduit installation
Enclosure:
• Integrated waterproof instrument enclosure, wire and cable junction box, and lockable rain shed
• Upper section NEMA4/IP66 (watertight), lower section NEMA3R (rain tight) or NEMA4 with cable glands
• 16 ga. steel, 14 ga. mounting flanges, TGIC powdercoated
• 14 x 12 x 5.5 inches (350 x 300 x 140mm), 20 lbs. (9 kg)
• Mini-rack mounting for internal modem options
• Swing-out panels for modem and 12V battery access
• Surface, truss-tower, or tube-tower mounting
• Single no-tools padlockable hasp closure
 
Available Options
• Vacuum Fluorescent Display
• GSM/GPRS, CDMA, and AMPS cellular modems
• Landline telephone (POTS) modem
• Integrated solar charging systems, including charge regulator, panel, mounting brackets, and lead-acid batteries