Couting Scales
Ohaus Ranger Count
![]() |
Designed for easy counting, the Ohaus Ranger Count has a high-resolution measuring technology which produces counting results that are fast, stable and precise. Automatic reference optimization assures accurate counting each and every time. Logical menu-based controls and a large backlit LCD display for comfortable operation. |
Two Rangers can be linked together for fast, accurate
dedicated parts counting and inventorying. The cast aluminum housing is well
suited for industrial or production environments. Choose from five capacities
in two platform sizes. For efficiency, speed and durability, the choice is Ranger
Count.
| FEATURES |
|
| SPECIFICATIONS | ||||||
|
Standard
model
|
RC3RS
|
RC6RS
|
RC12LS
|
RC30LS
|
RC60LS
|
|
|
CAT. NO.
|
RC3RS-2E0
|
RC6RS-2E0
|
RC12LS-2E0
|
RC30LS-2E0
|
RC60LS-2E0
|
|
|
Default Capacity x Readability (lb)
|
6 x 0.0005
|
12 x 0.001
|
24 x 0.002
|
60 x 0.005
|
120 x 0.01
|
|
|
Default Capacity x Readability (kg)
|
3 x 0.0002
|
6 x 0.0005
|
12 x 0.001
|
30 x 0.002
|
60 x 0.005
|
|
|
Default Capacity x Readability (g)
|
3000 x 0.2
|
6000 x 0.5
|
1200 x 1
|
30000 x 2
|
60000 x 5
|
|
|
Default Capacity x Readability (oz)
|
60 x 0.005
|
120 x 0.01
|
240 x 0.02
|
600 x 0.05
|
1200 x 0.1
|
|
|
Default Capacity x Readability (lb)
|
6 x 0.0005
|
12 x 0.001
|
24 x 0.002
|
60 x 0.005
|
120 x 0.01
|
|
|
Max. Capacity x Readability (kg)
|
3 x 0.00002
|
6 x 0.00005
|
12 x 0.0001
|
30 x 0.0002
|
60 x 0.0005
|
|
|
Max. Capacity x Readability (g)
|
3000 x 0.02
|
6000 x 0.05
|
12000 x 0.1
|
30000 x 0.2
|
60 x 0.05
|
|
|
NTEP Capacity x Readability (lb)
|
6 x 0.001
|
12 x 0.002
|
24 x 0.005
|
60 x 0.01
|
120 x 0.02
|
|
|
NTEP Capacity x Readability (kg)
|
3 x 0.0005
|
6 x 0.001
|
12 x 0.002
|
30 x 0.005
|
60 x 0.01
|
|
|
NTEP Capacity x Readability (g)
|
3000 x 0.5
|
6000 x 1
|
12000 x 2
|
30000 x 5
|
60000 x 10
|
|
|
NTEP Capacity x Readability (oz)
|
60 x 0.01
|
120 x 0.02
|
240 x 0.05
|
600 x 0.1
|
1200 x 0.2
|
|
|
Linearity
|
±0.2
|
±0.5
|
±1.0
|
±2.0
|
±5.0
|
|
| Ranger Factory Options | ||||||
| 1 | Battery | To order Ranger with internal rechargeable battery add /1 to the order number above | ||||
| 2 | Second RS232 | To order Ranger with second RS232 data interface, add /2 to the order number above | ||||
| 3 | Battery & Second RS232 | To order Ranger with both an internal rechargeable battery and sencond RS232 data interface add /3 to the order number above. | ||||
| General Specification | ||||||
|
CAT. NO.
|
RC3RS
|
RC6RS
|
RC12LS
|
RC30LS
|
RC60LS
|
|
| Functions |
Basic weighing, piece counting, piece counting with second scale |
|||||
| Internal resolution | 1 part in 300 000 | |||||
| Sample size | 5, 10, 15, 20, 25, 30, 50, 100 | |||||
| Platform size (WxD) (in/cm) | 9.5 x 8 / 24 x 20 | 14 x 9.5 / 35 x 24 | ||||
| Scale dimensions (WxDxH) (in/cm) | 10.5 x 13.2 x 4 / 26.5 x 33.5 x 10 | 14.2 x 14.6 x 4.5 / 36 x 37 x 11.5 | ||||
| Shipping dimensions (WxDxH) (in/cm) | 16.5 x 19 x 10 / 42 x 48 x 25 | 20 x 20.5 x 10.5 / 52 x 53 x 27 | ||||
| Weight (lb/kg) | 11.5 / 5
net (14 / 6.5 gross) |
21 / 9.5
net (24 x 11 gross) |
||||
| Weighing units | Pcs, g, kg, lb, oz | |||||
| Display | 0.63 inch. / 16 mm digit height, (Backlit LCD), with analog filling guide | |||||
| Power | Internal power supply / 40 hour rechargeable battery powered models available | |||||
| Construction | Stainless steel weighing pan / Painted cast-aluminum housing | |||||
| Protection | IP43 | |||||
| Operation temperature | Standard models: -10 to 40°C | |||||
| Storage temperature | -20 to 60°C | |||||
All Ranger Count models meets the requirements of Approval
Agencies: UL, FCC, CSA, CE Safety EN60950, Emissions EN55022, Immunity EN50082-1.
High internal resolution: 1 part in 300 000, automatic optimization of
reference weight, variable sample sizes, Add-Mode, Two scale capability.
| STANDARD FEATURES |
| RS232 bi-directional interface, backlit display, Gross / Tare / Net function, auto-off timer, internal AC power supply, leveling feet, leveling bubble, loop for security device, 10 button membrane keypad, rugged cast aluminum housing, auto zero tracking, retain zero data during power off, user selectable graduation, fill application option, automatic reference optimization to ensure accuracy of sample for parts counting, add mode to establish sufficient sample weight, user selectable averaging level sensitivity, primary and secondary display units user selectable, automatic taring, front-panel counting/weight switch, bar graph displaying percentage of total capacity, variable sample size user selectable, primary and secondary configurable RS232 port settings with programmable output header, software LFT lockout switch. |
| ACCESSORIES |
|
| FACTORY INSTALLED OPTIONS |
|
| INDUSTRY LEADING WARRANTY |
| All Ohaus Ranger Count scales are protected by a 5 year warranty on labor and parts. Our rugged construction and stringent quality control have been hallmarks of Ohaus scales and balances since 1907. |