| FEATURES |
- Efficient propeller-driven Photo-Fiber-Optic
sensor coupled with precision quartz crystal controlled electronics
provide accurate repeatable data in all flow conditions.
- The Model 2100 Indicator reads data in feet and meters
per second. A toggle switch in the battery compartment changes from
one to the other.
- Powered by a single 9 volt transistor battery and there is a spare in the battery compartment too.
- Three user selectable velocity averaging times in each
mode. From 5 to 90 seconds in feet per second and from 1.5 to 30 seconds
in meters mode.
- Sensor components (propeller, rotor, and rotor shaft)
easily and inexpensively replaceable. Carry spares into remote locations
and you'll never have to return early because of a bent bucketwheel,
lost sensor magnet or bent shaft.
- Wide choice of sensor carriers or "wands"
to accommodate virtually any open stream velocity measuring requirement.
- Lightweight, portable system is easy to work with all
day in the field. Indicator weighs a little over a pound and a half.
- A simple and accurate method of user-accomplished
calibration is provided with the Model 2100. No other current meter
provides the user a method of checking and changing calibrations while
in the field. Calibration settings for the feet and meters selection
are easily checked and changed any time.
|
| SPECIFICATIONS |
| Velocity
range |
0.1 to 25
feet per second (propeller meters) (0.03 to 7.5 meter per second) |
| Display |
4 digit,
Liquid Crystal Digital, 0.7" digits |
| Resolution |
To hundredths,
both feet and meters |
| Accuracy |
Can be held
to within 1% with periodic user-required calibration tests and adjustments. |
| Display
averaging |
Three selectable
averaging times |
- 5, 20 and 90 seconds-FPS mode.
- 1.5, 6 and 30 seconds-MPS mode.
|
| Operating temperature
|
- LCD: Min. -14°F (-25.6°C); Max. 180°F (82°C) @ 15%
humidity; Max. 120°F (49°C) @ 95% humidity
- Sensor: Min. 0°F (-17.8°C); Max. 194°F (90°C)
|
| Power required |
One 9 volt battery. Alkaline
or rechargeable NiCad |
| Indicator size |
4" by 6" by 2" inches (15.2
by 10.2 by 5.1 cm) |
| Indicator weight |
25 oz. (including 9 volt
batteries, one spare) |
| Indicator material |
Vacuum-formed ABS with a
clear acrylic viewing lens over the LCD. |
| Indicator keypad & switches |
Back-printed polycarbonate
in four colors plus black. Two pushbutton momentary switches, one rotary
switch with silicone boots for water seal. |
| Fasteners |
Stainless Steel and/or Brass |
| Sensor Wand materials |
Aluminum = 6061-T6, Stainless
Steel - #303 |
| Sensor body and rotor |
Acetron GP (rotor body) & Ertalyte® TX, an
internally lubricated thermoplastic polyester that
provides enhanced wear over all previous rotor
materials. |
| Sensor propeller |
Glass-filled nylon. 2"
diameter is supplied. Other sizes are available for special applications. |
| Electrical connection |
Polyurethane jacketed, dual Aramid core, high
strength cable. Two-conductor sensor signal
system. Circular plastic,water resistant connector
with twist-lock operation. Connections use gold
plated contacts. |
| Cable length |
Equal to wand at full extension plus five feet.
Special length to 1000'are also available. |
| Sensor type |
Photo-Fiber-Optic two-conductor electrical
with all electronics permanently encapsulated in epoxy resin. |
| CAT. NO. |
DESCRIPTION |
| 2100-TSR-Kit |
Current Velocity meter adapts
to your USGS Top-Set wading rod |
 |
| 2100-STDX |
Current Velocity meter and
2.5 ft. - 9.5 ft. Telescoping Wand |
| 2100-LX |
Current Velocity meter and
4.5 ft. - 19.5 ft. Telescoping Wand |
| 2100-12 |
Current Velocity meter and
2.7 ft. Top Set wading Rod |
| 2100-13 |
Current Velocity meter and
3.7 ft. Top Set wading Rod |
| 2100-14 |
Current Velocity meter and
4.7 ft. Top Set wading Rod |
| 2100-C80 |
Current Velocity meter and
80cm Top Set wading Rod |
| 2100-C140 |
Current Velocity meter and
140cm Top Set wading Rod |
| 2100-1514 |
Current Velocity meter and
12 ft. Combination Wading Rod |
| 2100-1518 |
Current Velocity meter and
4 meter Combination Wading Rod |
| Carrying Cases |
| P-1450 |
Pelican 1450® waterproof
polypropylene carrying case |
| P-1200 |
Pelican 1200® waterproof
polypropylene carrying case |
Digital Indicator only
(Available separately as replacements,
repairs or upgrades) |
| 2100-Indicator |
Current Velocity Indicator
with neck strap |
| Sensor Replacement Parts |
| 2100-A21 |
Complete Rotor Assembly; 2" prop, optics
rotor, shaft & thrust bearing nut |
|
| 2100-A22 |
Sensor w/o Rotor Assembly, up to 25' cable
w/ connector |
| 2100-A23 |
Thrust Bearing Nut |
| 2100-PROP |
Glass Filled Nylon Replacement Prop 2"
Dia.(standard) |
| 2100-PROP3 |
Glass Filled Nylon Replacement Prop 3"
Dia. |
| 2100-PROP1 |
Glass Filled Nylon Replacement Prop 1 3/8"
Dia. |
| 2100-A25 |
Replacement retainer snap ring for rotor shaft
|
| 2100-A26 |
Stainless Steel Rotor Shaft (also includes
a retainer snap ring) |
| 2100-A27 |
Fiber Optics Rotor |
| 6-32 Set Screw |
Sensor and Rotor retaining screw |
| 1ž2" Cap Plug |
1ž2" Cap Plug (Protects sensor when not
in use) |
| Extension Cable |
Sensor Extension Cable, any length, twist lock
connector at both ends |