Geneq > Teaching Equipment > Fluid Mechanics

Capillary viscometer
Model PBC 100


  • The capillary viscometer is delivered complete with instrumentation and includes a technical and instruction manual.
  • The liquid to be studied is placed in a thermostatically controlled pressurized container which is connected
    to a capillary tube that is also found in a thermostatically controlled environment. The liquid is continuously agitated to ensure that it remains homogeneous. The unit can be dismantled.
UTILITIES
Electricity : 230 V single phase - 50/60 Hz Compressed air: 1 bar minimum

DIMENSIONS
Length : 760 mm Width : 560 mm Height : 600 mm Weight : 60 kg

Application
From measurement of flow and loss of pressure in the capillary, the viscometer can be used:
  • For a study of Poiseuille (laminar) flow of a known viscosity liquid
  • To determine precisely the radius of the capillary tubes
  • To measure the dynamic viscosity of a liquid and to study how this varies with temperature
  • To study the shear force in viscous fluids and rubbing forces on the tubes during laminar flow.

Specifications
Characteristics
Capillary tubes : 0.2 mm and 0.4 mm - length 400 mm
Temperature scale : 90°C to ± 0,5°C
Pressure scale : 0 – 1 bar

Control and measurement appliances
The unit is manufactured with :
- A manometer – Tube of Bourdon Ø160
- A thermometer
- A stopwatch for level measurement
- Two graduated pipettes
- A heat regulated bath
- A magnetic agitator