GENEQ > Environnement > Électrodes - pH

Électrodes de pH
Orion ROSS


Table 1


Orion
81-02
Orion
81-03
Orion
81-04
Orion
81-15
Orion
81-35
Orion
81-55/56

Orion 81-02

ROSS Combinaison with glass body
Recommended Use:
Precise PH - determinations. The general purpose, top performance combinaison electrode. Ideal for Q.C. and research applications.
Orion# 8102BN (1) - 810200 (2) - 8102SC (3)


Orion 81-03

ROSS Combinaison with glass body, semi-micro
Recommended Use : Fits test tubes, measures samples as small as 0.2 ml. For use in clinical, pharmaceutical, and food labs, wherever sample size is a constraint.
Orion# 8103BN (1) - 810300 (2) - 8103SC (3)


Orion 81-04

ROSS Combinaison with glass body rugged bulb
Recommended Use : Toughened bulb for rugged lab use and precise Q.C. measurements.
Orion# 8104BN (1) - 810400 (2) - 8104SC (3)


Orion 81-15

ROSS Combinaison with epoxy body, semi-micro.
Recommended Use : Epoxy body for ruggedness and durability. Same applications as 81-03. Aqueous solutions only.
Orion# 8115BN (1) - 811500 (2) - 8115SC (3) - Detachable Bulb guard included


Orion 81-35

ROSS Combinaison with epoxy body, flat surface.
Recommended Use : pH of soft, moist surfaces both solid and semi-solid such as agar gel plates, meats, bread dough and similar samples. Small samples in micro sample dish.
Orion# 8135BN (1) - 813500 (2) - 8135SC (3)


Orion 81-55/56

ROSS Combinaison with epoxy body.
Recommended Use : General purpose when precise pH determination is required. Epoxy body for ruggedness and durability.
Orion# 815500 (2) - 815600 (1) - 8155SC (3)


Table 1

Orion ROSS
81-002
81-03
81-04
81-15
81-35
81-55/56
pH Range
0-14
0-14
0-14
0-14
0-14
0-14
Temp.Range
0-100șC
0-100șC
0-100șC
0-100șC
0-100șC
0-100șC
Internal Ref.
ROSS
ROSS
ROSS
ROSS
ROSS
ROSS
Junction
Ceramic
Ceramic
Ceramic
Glass Fiber
Glass Fiber
Glass Fiber
Dimensions
120 mm x 12 mm
165 mm x 6 mm (6mm sction is 95mm long)
120 mm x 12 mm
165 mm x 6 mm (6mm sction is 95mm long)
120 mm x
12 mm
120 mm x
12 mm

Table 2

Orion
8175BNWP
Orion
81-65
Orion
81-72
Orion
8162C
Orion
81-63
Orion
8166SC
Orion
81-01
Orion 81-75BNWP
Top page

ROSS Sure-Flow Semi-Micro, epoxy body.
Recommended Use : For use in test tubes and small samples; recommended for soil and viscous samples.
Orion# 8175BNWP (1) Detachable bulb guard included


Orion 81-65

ROSS Sure-Flow Combinaison with epoxy body
Recommended Use : Field ph measurement where stability and high performance is desired, on-site soil ph. Rugged durable construction.
Orion# 8165BNWP (1) - 8165DN (5) - Detachable bulb guard included


Orion 81-72

ROSS Sure-Flow Combinaison with epoxy body
Recommended Use : General purpose, superior performance ideal for dirty, difficult samples such as soils, sludges, colloids, viscous materials ans organics.
Orion# 8172BNWP (1) - 8172DN (5) - Detachable bulb guard included


Orion 8162SC

ROSS Combinaison with glass body, with 14/15 standard taper screw cap connector.
Recommended Use : For many titrators or vessels requiring standard taper joint.
Orion# 8162SC (3) -


Orion 81-63

ROSS Combinaison with glass body, spear tip.
Recommended Use : ph in semisolid food material such as cheese, meat, fruit, bread, and other similar samples. Sample sizes to 100ul.
Orion# 8163BNWP (1) - 816300 (2) - 8163SC (3)


Orion 8166SC

ROSS Combinaison Steeve, Junction pH Electrode, screw cap connector.
Recommended Use : For use with most titrators; use in viscous samples where cleaning is an issue.
Orion# 8166SC (3)


Orion 81-01

ROSS pH Half-Cell with glass body.
Recommanded Use : Precise ph determinations for routine or research work. Use with ROSS Reference Electrode 80-03 or 80-05.
Orion# 8101BNWP (1) - 810100 (2) - 8101SC (3)


Table 2

Orion ROSS
8175BNWP
81-65
81-72
8162SC
81-63
8166SC
81-01
pH Range
0-14
0-14
0-14
0-14
0-14
0-14
0-14
Temp.Range
0-100șC
0-100șC
0-100șC
0-100șC
0-100șC
0-100șC
0-100șC
Internal Ref.
ROSS
ROSS
ROSS
ROSS
ROSS
ROSS
NA
Junction
Ceramic
Ceramic
Ceramic
Glass Fiber
Glass Fiber
Glass Fiber
_
Dimensions
120 mm x 12 mm
165 mm x 6 mm (6mm sction is 95mm long)
120 mm x 12 mm
165 mm x 6 mm (6mm sction is 95mm long)
120 mm x 12 mm
120 mm x 12 mm
120 mm x 12 mm

Table 3


Orion
80-03
Orion
80-05
Top page

Orion 80-03

ROSS Sure-Flow Reference Half-Cell with glass body.
Recommanded Use : With 81-01 for pH in soils, viscous, colloidal or other dirty samples. With 84-11 for sodium in foods or other difficult-to-clean samples.
Orion# 800300 (4)


Orion 80-05

ROSS Reference Half-Cell with glass body.
Recommanded Use : With 81-01 for routine pH measurements
and 8411 for sodium measurements
Orion# 800500 (4)


Table 3

Orion ROSS Reference
80-03
80-05
pH Range
0-14
0-14
Temp.Range
0-100șC
0-100șC
Internal Ref.
ROSS
ROSS
Junction
Sure-Flow
Ceramic
Dimensions
120 mm x 12 mm
120 mm x 12 mm

KEY for all
(1) BNC connector, 1m cable,
(2) US standard connector
(3) Screw cap connector, requires separate cable.
(4) Pin Tip Connector
(5) Use with Orion 260A, 261, 261S, 265A, 266, 266S.
All cap diametrers are 16 mm at bottom of cap.