GENEQ > Environnement > Électrodes - pH

Électrodes de pH de Orion
Orion PerpHect® et Orion Standard


See Orion Standard

Orion PerpHect® - part 1


Orion
8202BN
Orion
B203BN
Orion
8235BN
Orion
8256BN
Orion
8263BN
Orion
8272BN

Orion 8202BN

ROSS Combinaison with glass body
Recommended Use:
Precise PH - determinations. The general purpose, top performance combinaison electrode. Ideal for Q.C. and research applications.
Orion# 8202BN (1)


Orion 8203BN

ROSS Combinaison with glass body, semi-micro
Recommended Use : Fits test tubes, measures samples as small as 0.2 ml. For use in clinical, pharmaceutical, and food labs, wherever sample size is a constraint.
Orion# 8203BN (1)


Orion 8235BN

ROSS Combinaison with epoxy body, flat surface
Recommended Use : pH and soft, moist surfaces both solid and semi-solid such as agar gel plates, meats, bread dough, and similar samples. Small samples in micro sample dish.
Orion# 8235BN (1)


Orion 8256BN

ROSS Combinaison with epoxy body.
Recommended Use : General purpose when precise pH determination is required. Epoxy body for ruggedness and durability.
Orion# 8256BN (1)


Orion 8263BN
ROSS Combinaison with glass body, spear tip.
Recommended Use : pH in semi-solid food material such as cheese, meat, fruit, bread, and other similar samples. Samples sizes to 100 ul.
Orion# 8263BN (1)

Orion 8272BN

ROSS Sure-Flow® Combinaison with glass body
Recommended Use : General porposesuperior performance ideal for dirty, difficult samples such as soils, sludges, colloids, viscous materials and organics.
Orion# 8272BN (1) Detachable bulb guard (Orion 910005) included


Top page

Orion PerpHect® - part 2


Orion
9202BN
Orion
9203BN
Orion
9206BN
Orion
9207BN
Orion
9256BN
Orion
9272BN

Orion 9202BN

Combinaison with glass body
Recommended Use : General purpose pH for accurate Q.C. and research applications
Orion# 9202BN (1)


Orion 9203BN

Combinaison with glass body, semi-micro
Recommended Use : Small samples, test tubes. Minimum sample volume 0.2-0.4 mL
Orion# 9203BN (1)


Orion 9206BN

Combinaison with epoxy body, non-refilable
Recommended Use : Routine pH for rugged use, schools, field and plant applications.
Orion# 9206BN (1)


Orion 9207BN

Epoxy body, Triode ™ 3-in-1 pH/ATC Probe BNC//phone connectors. non-refilable
Recommended Use : Routine pH ideal for fieldor plantuse. Portable, littleor no maintennce needed
Used with Orion PerpHecT Meters and SensorsLink® Systems
Orion# 9207BN (1)


Orion 9256BN

Combinaison with epoxy body
Recommended Use : Routine pH for field, school, or lab use. Epoxy body for ruggedness and durability, refilable.
Orion# 9256BN (1)


Orion 9272BN

Glass body Sure flow Combinaison pH
Recommended Use : General purpose, superior performance ideal for dirty, difficultsamples such as soils, sludges, colloids, viscous materials ans organics.
Orion# 9272BN (1)


Top page

Orion Standard - part 1


Orion
91-01
Orion
91-02
Orion
91-03
Orion
91-04
Orion
91-07
Orion
91-09

Orion 91-01

Ag/AgCI ph Half-Cell with glass body
Recommanded Use : For accurate, reproductible results. Recommended general use electrode pair. Use with 90-01 Reference Electrode.

Orion# 91-01BN (1) - 910100 (2) - 9101SC (3)


Orion 91-02

Combinaison with glass body
Recommanded Use : General purpose pH for accurate Q.C. and research work.
Orion# 9102BNWP (1) - 910200 (2) - 9102SC (3)


Orion 91-03

Combinaison with glass body, semi-micro
Recommanded Use : Small samples, test tubes. Minimum samples, test tubes. Minimum sample volume 0.2-0.4 mL
Orion# 9103BNWP (1) - 910300 (2) - 9103SC (3)


Orion 91-04

Combinaison with glass body, "hard nose" bulb
Recommanded Use : For rugges, durable lab use.
Orion# 9104BNWP (1) - 910400 (2) - 9104SC (3)


Orion 91-07

Epoxy body, Triode™ 3-in-1 pH/ATC Probe Non-refilable
Recommanded Use : Routine pH. Ideal for field or plant use. Portable, little or no maintenance needed.
Orion# 9107BN (1) - (4) - 9107WP (6)-(7) 1M cable - 9107WL (6)-(7) 6M cable -
            9107BNMD (9) 1.5 M cable - 9107WMMD (9) 3M cable - 9107WLMD (9) 6M cable


Orion 91-09

Epoxy body, Triode™ 3-in-1 pH/ATC Probe Non-refilable
Recommanded Use : Routine pH. Ideal for field or plant use. Portable, little or no maintenance needed.
Orion# 9100WP (5) - (7) 1M cable - 9109WL (5)-(7) 6M cable


Top page

Orion Standard - part 2


Orion
91-55/56
Orion
91-57
Orion
91-61
Orion
91-62
Orion
9165BNWP
Orion
91-72

Orion 91-55/56

Combinaison with epoxy body
Recommanded Use : Routine pH: for rugged use: for field, school, or lab use. Unbreakable body, refilable
Orion# 915500 (2) - 9156BNWP (1) - 9156SC (3)


Orion 91-57

Epoxy body, Triode™ 3-in-1 pH/ATC Probe BNC/DIN connectors, refilable
Recommanded Use : Routine pH. Ideal for field or plant use.
Orion# 9157BN (1) (4) - 9157WP (5) (7) - 9157BNMD (9) 1M cable


Orion 91-61

Low resistance pH Half-Cell with glass body, rugged bulb
Recommende Use : Routine pH where ruggedness is important. Use with 90-01 Reference electrode
Orion# 9161BN (1) - 916100 (2) - 9161SC (3)


Orion 91-62

Low Resistance Combinationwith glass body , rugged bulb
Recommende Use : More rugged, use in viscous solutions. Easy-to-clean bulb design.
Orion# 9162BNWP (1) - 916200 (2) - 91662SC (3)


Orion 9165BNWP

Epoxy-Body Sure-Flow® Combination pH Electrode with BNC Connector
Recommended use : General purpose, ideal for dirty, difficult samples such as soils, sludges, colloids, viscous solutions. Easy to-clean-junction never clogs.
Orion# 9165BNWP (1) Detachable bulb guard (Orion 910005) included


Orion 91-72

Glass-body Sure-Flow Combination pH Electrode with BNC Connector
Recommended use : Same as 9165BN - Ideal for general lab use
Orion # 9172BNWP (1)


Orion PerpHect®
8202BN
8203BN
8235BN
8256BN
8263BN
8272BN
pH Range
0 -14
0 -14
0 -14
0 -14
0 -14
0 -14
Temp.Range
0 -100°
0 -100°
0 -100°
0 -100°
0 -100°
0 -100°
Internal Ref.
ROSS
ROSS
ROSS
ROSS
ROSS
ROSS
Junction
Ceramic
Ceramic
Glass fiber
Glass-fiber
Ceramic
Sure-Flow
Dimensions
120 mm x 12 mm
165 mm semi-micro section is 6 x 95 mm 95mm long)
120 mm x 12 mm
120 mm x 12 mm
110 x 4.5 mm 4.5 section is 23 mm
120 mm x 12 mm
Slope
92 - 102%
92 - 102%
92 - 102%
92 - 102%
92 - 102%
92 - 102%
Temp. Acc.
±0.5șC
±0.5șC
±0.5șC
±0.5șC
±0.5șC
±0.5șC
9202BN
9203BN
9206BN
9207BN
9256BN
9272BN
pH Range
0 -14
0 -14
0 -14
0 -14
0 -14
0 -14
Temp.Range
0 - 90°
0 - 90°
0 - 80°
0 - 80°
0 - 90°
0 - 100°
Internal Ref.
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Junction
Ceramic
Ceramic
Wick
Glass Fiber
Glass Fiber
Sure-Flow
Dimensions
120 mm x 12 mm
140 mm semi-micro section is 100 x 6.5 mm
165 mm semi-micro section is 95 x 6 mm
120 mm x 12 mm
165 mm x 6 mm (6mm section is 95mm long)
120 mm x 12 mm
Slope
92-102%
92-102%
92-102%
92-102%
92-102%
92-102%
Temp. Acc.
±0.5șC
±0.5șC
±0.5șC
±0.1șC
±0.5șC
±0.5șC

Orion Standard
91-01
91-02
91-03
91-04
91-07
91-09
pH Range
0 -14
0 -14
0 -14
0 -14
0 -14
0 -14
Temp.Range
0 - 90°
0 - 90°
0 - 90°
0 - 90°
0 - 90°
0 - 90°
Internal Ref.
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Junction
NA
Ceramic
Ceramic
Ceramic
Wick
Wick
Dimensions
110 mm x 12 mm
120 mm x 12 mm
140 mm semi-micro section is 100 x 6.5 mm
120 mm x 12 mm
120 mm x 6 mm
120 mm x 12 mm
91-55/56
91-57
91-61
91-62
9165BNWP
91-72
pH Range
0 -14
0 -14
0 -14
0 -14
0 -14
0 -14
Temp.Range
0 - 90°
0 - 90°
0 - 90°
0 - 90°
0 - 100°
0 - 100°
Internal Ref.
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Junction
Glass Fiber
Glass Fiber
NA
Ceramic
Sure-Flow
Sure-Flow
Dimensions
120 mm x 12 mm
120 mm x 12 mm
110 mm x 12 mm
120 mm x 12 mm
120 mm x 12 mm
120 mm x 12 mm

KEY for all
(1) BNC connector, 1m cable
(2) US standard connector, 1m cable
(3) Screw cap connector, requires separate cable
(4) Use with Orion 210A/A - 230A/A - 250A/A - 410A/A - 420A/A - 520A/A - 525A/A - 710A/A - 720A/A - 920A/A
(5) Use with Orion 260A, 261, 261S, 265A, 266, 266S
(7) Waterproof EDIN with babana plug
(8) MiniDIN connector for Orion Star™ Series meters
(9) BNC + MiniDIN connector for Orion Star™ Series meters
All cap diametrers are 16 mm except Orion 9157WP, Orion 9109WP and Orion 9109WL are 22 mm maximum