GENEQ > Environnement > Électrodes - pH

Électrodes de pH de Orion
 


See table
Orion
71-20/9120APWP
Orion
51-07/09
Orion
91-05/06
Orion
91-35/36
Orion
91-25/26
Orion
91-15/16
Orion
7102BN
Orion
9103APWP
Orion
9110DJWP
 

Orion 71-20/9120APWP

KNIpHE pH Electrode Stainless steel cutting blade surrounding a special combinaison pH electrode
Recommended Use:
For ph determinations in meats ans meat by-products where glass electrodes alone may break

Orion# 7120BN (1) (6) - 9120APWP - 7121BN Replacement KNIpHE pH Electrode
         # 712001 Replacement Blade - 712002 Protective Sheath


Orion 51-07/09

Combinaison electrode with Epoxy Body
Recommended Use : Field pH measurement where stability and high performance is desired and when a pH electrode that doesn't require calibration is needed.
Orion# 5107NC (4) - 5109NC (5) - 5107BNMD (7)


Orion 91-05/06

Combinaison with epoxy body. Non-refilable
Recommended Use : Routine pH for rugged use, schools, field and plant applications.
Orion# 910500 (2) - 9106BNWP (1)


Orion 91-35/36

Combinaison with epoxy body. Non-refilable. Flask electrode
Recommended Use : Routine pH for use in long-necked flasks and other tall vessels.
Orion# 912500 (2) - 912600 (1)


Orion 91-25/26
Combinaison with epoxy body, spear tip.
Recommended Use : pH in semi-solid food material such as cheese, meat, fruit, bread, and other similar samples. Samples sizes to 100 ul.
Orion# 8263BN (1)

Orion 91-15/16

Combinaison with epoxy body Non-refilable, semi-micro.
Recommended Use : Routine pH for use in test tubes, small samples.
Orion# 911500 (2) - 911600 (1)


Orion 7102BN

Glass-body Combinaison Calomel pH Electrode with screw cap connector
Recommended Use : Routine pH measurements in all biotech samples. Ideal for use with and in Tris-buffers
Orion# 7102BN (1)


Orion 9103APWP

Glass-body Semi-Micro Combinaison Calomel pH Electrode with screw cap connector
Recommended Use : Small samples, test tubes, same as 71-02. Minimum sample volume: 0.2-0.4 mL
Orion# 9103APWP (1)


Orion 9110DJWP

Glass-body Micro Combinaison Calomel pH Electrode with screw cap connector
Recommended Use : Very small samples, microtiter plates. Same as 71-02. Minimum volume: 0.1 mL
Orion# 9110DJWP (1) - 711002 Micro Flow Cell for 7118BN Calomel pH Electrode

Top page

See table

Orion
9102AP
Orion
9103APWP
Orion
91104APWP
Orion
9115APWP
Orion
9135APWP
Orion
9156APWP

Orion 9102AP

AquaPro Combinaison Low Maintenance™ double junction with glass body
Recommanded use : General purpose pH, double junction, no sample contact with AG.
Orion# 9102AP (1)


Orion 9103APWP

AquaPro Combinaison Low Maintenance™ double junction with glass semi-micro
Recommanded use : Small samples, test tubes. Minimum sample volume 0.200.4 mL
Orion# 9103APWP (1)


Orion 9104APWP

AquaPro Combinaison Low Maintenance™ double junction with glass body, "hard nose" bulb.
Recommanded use : Rugged durable lab use, double junction, no sample contact with Ag.
Orion# 9104APWP (1)


Orion 9115APWP

AquaPro Combinaison Low Maintenance™ double junction epoxy semi-micro.
Recommanded use : Small samples, test tubes. Aqueous solutions only. Minimum sample volume 0.2-0.4 mL
Orion# 9115APWP (1)


Orion 9135APWP

AquaPro Combinaison Low Maintenance™ double junction epoxy flat-surface.
Recommanded use : pH of moist, surface, both solid and semi-solid such as agar gel plates, meats, bread dough and similar samples. Small samples in micro sample dish.
Orion# 9135APWP (1)


Orion 9156APWP

Combinaison Low Maintenance™ double junction with epoxy body.
Recommanded use : Routine pH. Rugged durable lab or field use, double junction.
Orion# 9156APWP (1)


Top page
See table

Orion
9179BNMD
Orion
9180BNMD
Orion
9678BNWP
Orion
9778BNWP

Orion 9179BNMD
Epoxy Low Maintenance ORP Triode
Recommended Use : Measurement of oxidation/reduction potential and temperature
in water/wastewater, metal plating, and biotech
Orion# 915500 (2) - 9156BNWP (1) - 9156SC (3)

Orion 9180BNMD

Epoxy Refilable ORP Triode
Recommended Use : Measurement of oxidation/reduction potential and temperature
in water/wastewater, metal plating, and biotech
Orion# 9180BNMD (7) - 9180 (1) (8)


Orion 9678BNWP

Epoxy Sure-Flow® Combination Redox/ORP
Recommended Use : For measurement of reduction/oxidation potential and Redox titrations.
Orion# 9678BNWP (1) - 967800 (2)


Orion 9778BNWP

Glass Combination Redox/ORP
Recommended Use : For measurement of reduction/oxidation potential and Redox titrations.
Orion# 9778BNWP - 877800 (2) - 8778SC (3)


See illustration
Orion KNIpHE®
Orion D/J KNIpHE®
Orion NO Cal®
Orion Tris Calomel Line
 
71-20
9120APWP
51-07/09
7102BN
7103BN
7110BN
pH Range
0 -14
0 -14
0 -14
0 -14
0 -14
0 -14
Temp.Range
0 - 60°
0 -60°
0 -100°
0 -90°
0 -90°
0 -90°
Internal Ref.
Calomel
Ag/AgCI Double Junction
Patent pending, Double Junction
Calomel
Calomel
Calomel
Junction
Ceramic
Ceramic
Ceramic
Ceramic
Ceramic
Ceramic
Dimensions
215 mm x 25 mm cap dia 16 mm
120 mm x 12 mm
110 mm x 12 mm (5 mm section is 90 mm long. cap dia 16 mm)
210 mm x 7 mm, cap dia 16 mm
150 mm x 5 mm, 7 mn section is 150 mm long, cap dia 16 mm
Orion Double Junction Ag/AgCI Tris Line
 
9102DJWP
9110DJWP
9156DJWP
 
pH Range
0 -14
0 -14
0 -14
 
Temp.Range
0 - 60°
0 - 60°
0 - 60°
 
Internal Ref.
Ag/AgCI Double Junction
Ag/AgCI Double Junction
Ag/AgCI Double Junction
 
Junction
Ceramic
Ceramic
Wick
 
Dimensions
       
Orion Economy Line
91-05/06
91-35/36
91-25/26
91-15/16
9145BN
9142BN
9147BN*‡
pH Range
0 -14
0 -12
0 -12
0 -14
0 -14
0 -14
0 -14
Temp.Range
0 - 80°
0 - 80°
0 - 80°
0 - 80°
0 - 80°
0 - 100°
0 - 80º
Internal Ref.
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Junction
Wick
Wick
Wick
Wick
Wick
Ceramic
PE Rod
Dimensions
120 mm x 12 mm, cap dia 16 mm
110 mm x 12 mm, cap dia 16 mm
165 mm x 6 mm (6mm section is 95mm long)
150 mm x 6 mm
120 mm x 12 mm, cap dia 16 mm
120 mm x 12 mm
120 mm x 12 mm

See illustration
Orion AquaPro Professional
9102AP
9103APWP
9104APWP
9107APWP
9115APWP
9135APWP
9156APWP
pH Range
0 -14
0 -14
0 -14
0 -14
0 -14
0 -14
0 -14
Temp.Range
0 - 60°
0 - 60°
0 - 60°
0 - 60°
0 - 60°
0 - 60°
0 - 80º
Internal Ref.
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Junction
Double Junction Open
Double Junction Open
DoubleJunction Open
Double Junction Epoxy / Open
Double Junction Epoxy / Open
Double Junction Epoxy / Open
Double Junction Epoxy / Open

See illustration
Orion Redox/orp and ORP Triode™
9179BNMD
9180BNMD
9678BNWP
9178BNWP
Temp.Range
0 - 90°
0 - 80°
0 - 80°
0 - 100°
Internal Ref.
Ag/AgCI
Ag/AgCI
Ag/AgCI
Ag/AgCI
Junction
Wick
Wick
Sure-Flow
Ceramic

KEY for all

(1) BNC connector, 1m cable
(2) US standard connector, 1m cable
(3) Screw cap connector, requires separate cable
(4) BNC Conector with 8 pin DIN
(5) E Din Connector
(6) 7120BN KNlpHE Electrode Kit includes: pH Electrode, Electrode Handle, Removable blade
(7) BNC Connector MiniDIN Connector for Orion Star™ Series meters 1m cable