GENEQ > Biotechnology > pH Meters

pH / mV / Temperature Meter
Model 3520


FEATURES
  • Ideal for quality control and GLP applications
  • 3 decimal place resolution
  • 1, 2 or 3 point pH calibration
  • Choice of pH calibration buffer types
  • Differential pH input
  • RS232 serial interface and IrDA printer interface
  • Analogue recorder output
  • Back lit 1/8 VGA monochrome LCD
  • Wall mounting option

The Model 3520 is a fully specified laboratory pH/mV/temperature meter that includes full suport for good laboratory practices (GLP).
The meter supports 1, 2 and 3 point pH calibration on either manually entered pH buffer values or automatically temperature compensated buffers to DIN, JIS and NIST.

Powerful data logging capabilities are included, with the ability to store up to 500 readings either manually, at timed intervals or on alarm events.

SPECIAL FEATURES FOR GOOD LABORATORY PRACTIVE (GLP)
  • Security code protected user data
  • Calibration data status display
  • Calibration reminder
  • 500 reading memory
  • Comprehensive data logging options
  • Alarm outputs (open collector and audible)

SPECIFICATIONS
pH Range (1, 2 or 3 point cal) -2.000 to 20.000pH
Resolution 0.001 / 0.01 / 0.1pH
Accuracy ±0.003pH
mV Range (Abs & Rel) 0 to ±1999.9mV
Resolution 0.1mV / 1mV
Accuracy ±0.2mV
Input impedance >1012ohms
Temperature ranges -10 to +105°C / 14 to 221°F
Resolution 0.1°C / 1°F
Accuracy ±0.5°C / ±1°F
ATC range 0 to 100°C / 32 to 212°F
Manual Temp. Comp. 0 to 100°C / 32 to 212°F
Calibration User selectable 1, 2 or 3 point
Auto Buffer selection
  • Jenway (2.00, 4.00, 7.00, 9.20, 10.00)
  • DIN (3.06, 4.65, 6.79, 9.23, 12.75)
  • NIST (1.68, 4.01, 6.87, 9.18, 12.45)
  • JIS (1.68, 4.01, 6.87, 9.18, 12.45)
  • or manually entered buffers
Calibration 1, 2 or 3 point pH
Outputs Analogue, RS232 and IrDA printer interface, Alarm
Clock 24 hours, hrs/min/sec or day of month/month/year, leap year corrected (European and American formats)
GLP
  • Calibration reminder interval (1 to 999 hours)
  • Alarm outputs (open collector and audible)
  • Security code protected user data
Display Back lit 1/8 VGA monochrome LCD
Language Options English, French, German, Italian, Portuguese and Spanish
Power Power supply 9V a.c.
Size 210 x 250 x 55mm
Weight 850g

CAT. NO. DESCRIPTION
JE352001-0 Model 3520 pH meter supplied with glass combination electrode (924 005), electrode holder, ATC probe (027 500), pH 4, 7 and 10 buffer sachets, UK power supply, BNC shorting plug (009 146), condensed operating instructions and instruction manual
JE352101-0 Model 3520 pH meter supplied with glass combination electrode (924 005), electrode holder, ATC probe (027 500), pH 4, 7 and 10 buffer sachets, US power supply, BNC shorting plug (009 146), condensed operating instructions and instruction manual
JE352201-0 Model 3520 pH meter supplied with glass combination electrode (924 005), electrode holder, ATC probe (027 500), pH 4, 7 and 10 buffer sachets, European power supply, BNC shorting plug (009 146), condensed operating instructions and instruction manual
JE352301-0 Model 3520 pH meter supplied with glass combination electrode (924 005), electrode holder, ATC probe (027 500), pH 4, 7 and 10 buffer sachets, 230V leaded power supply, BNC shorting plug (009 146), condensed operating instructions and instruction manual
Accessories
JE060406-0 Dust cover
JE037901-0 Bench stirrer (battery operated)
JE903311-0 Extended length electrode rod (recommended for use with the bench stirrer)
JE903300-0 Electrode Holder
JE924001-0 Epoxy bodied combination pH electrode
JE924005-0 Glass bodied combination pH electrode
JE027500-0 ATC probe
JE037701-0 IrDA/Serial printer supplied with roll of thermal paper, serial connection lead, power supply and 3 power connection leads
JE03702-0 Roll of thermal paper
JE037801-0 Interface cable kit
JE021030-0 UK 230V power supply
JE021031-0 European 230V power supply
JE021032-0 US 115V power supply
JE021033-0 230V leaded power supply
JE025179-0 pH 4 buffer sachets (pack 10)
JE025180-0 pH 7 buffer sachets (pack 10)
JE025181-0 pH 10 buffer sachets (pack 10)
JE025037-0 pH 4 coloured buffer solution (red) (500ml)
JE025038-0 pH 7 coloured buffer solution (yellow) (500ml)
JE025039-0 pH 10 coloured buffer solution (blue) (500ml)
JE025162-0 pH 9.22 buffer solution (500ml)
JE025163-0 pH 2 buffer solution (500ml)
JE025160-0 3M KCl electrode fill solution
JE025161-0 Electrode cleaning solution (pH)
JE025157-0 Redox standard (200mV) (500ml)
JE025158-0 Redox standard (300mV) (500ml)
JE025159-0 Redox standard (465mV) (500ml)