- 16 Bit Resolution
- Memory: 32,767 readings
- Programmable Scale Factor
- Programmable Offset Value
- Memory Wrap Around
- Reusable
- Miniature Size
- User Calibration through Software
- No Programming Experience Necessary
- Real Time Operation
- Low Cost
- Operational in Minutes
- Record Keeping Simplified
- Engineering Units can display instruments values
|
- 4.0 to 20.0 milli-Amp Recording
- pH Recording
- Remote Monitoring of low level signals
- Battery Studies
- Photovoltaic Studies
- Biological Sensor Monitoring
- Environmental Studies
- Replace Costly Strip Chart Recorders
|
| CALIBRATED CURRENT ACCURACY |
0.1% of F.S.R. at calibration temperature |
| CURRENTRESOLUTION |
10 microAmps |
| CURRENT RANGE |
-20 to +100 milliAmps |
| INPUT CONNECTION |
removable screw terminal |
| INPUTIMPEDANCE |
10 Ohm |
| ADC RESOLUTION |
16 Bits |
| CURRENT CALIBRATION |
Digital calibration is available in software. |
| N.I.S.T. TRACEABLE |
N.I.S.T. certificates available |
| CALIBRATION DATE |
Automatically recorded within device to alert user when calibration is required. |
| RECORDING INTERVAL |
From 2 sec. to 12 h selectable in software. |
| MEMORY WRAP AROUND |
Selectable in software. |
| ENGINEERING UNITS |
Software programmable. User may program any desired units up
to 10 characters in length. This value is stored within the device. |
| SCALE FACTOR |
Software programmable. User may program any desired scaling factor
from ±1.000E+99 to ±1.000E-99. The scaling factor is stored within the device. |
| OFFSET VALUE |
Software programmable. User may program any desired offset value
from ±1.000E+99 to ±1.000E-99. This offset value is stored within the device. |
| REAL TIME RECORDING |
Device may be used with PC to monitor and record data in real time. |
| GREEN VISUAL INDICATOR LED |
flashes at selected reading rate. |
| MEMORY |
32,768 readings max. |
| USER-REPLACEABLE BATTERY |
1 year typical. |
| TIME ACCURACY |
±1 minute per month at 20°C. |
| DATA FORMAT |
date and time stamped, mA, other engineering units programmable through software. |
| SHOCK RESISTANCE |
Drop proof to 5'. |
| WEIGHT |
1.5 oz. (40g) |
| COMPUTER INTERFACE PC |
serial or RS232C COM. |
| SOFTWARE |
Windows® 95/98/NT/2000/XP based software for complete control and operation. |
| OPERATING ENVIRONMENT |
-40°C to +80°C, 5 to 95 % RH (non-condensing). |
| DIMENSIONS |
1.4"H x 3.6"L x 0.6"D (36mm x 92mm x 16mm) |
| MATERIAL ABS |
Plastic |
| The software used to operate the Process101 requires no programming skills,
enables users to effortlessly select reading rate, user ID and initiate the start of data collection
within moments after user connects hardware. After retrieving the data,
it may be viewed instantly in graphical or tabular form. |
| ZOOM IN/OUT |
Use mouse to click and drag to select area for zooming in or out. |
| STATISTICS |
min, max, mean, standard deviation |
| CURSOR |
Use mouse to click on graph to obtain specific reading information. |
| REAL TIME OPERATION |
Convert PC into strip chart recorder for realtime data collection. |
| ANNOTATING DATA |
All data points may be easily annotated. |
| PRINTING |
Automatic printing of data in graphical or tabular form. |
| SCALING |
Current or user specified engineering units |
| USER ID |
Programmable through software and stored within device. |
| AUTOSCALE |
Autoscale function may be enabled or disabled by user. |
| CALIBRATION |
Automatic calibration in software and calibration parameters stored in device. |
| EXPORTING DATA |
All data can be directly exported to Microsoft Excel® or to text format. |
| GRAPH GRID SIZE |
The grid size is user selectable. |
| Process101 |
-20 to +100 milliAmp Current Recorder |
| IFC101 |
Software, Manual and 9 pin Computer Interface Cable |
| N.I.S.T. |
Cert N.I.S.T. Calibration Certificate |
| LTC-7PN |
User replaceable Lithium battery |