GENEQ > Biotechnology > Syringe Pumps

Programmable Syringe Pumps
 

  
BUILT FOR AUTOMATION
  • Operates stand-alone or from a computer.
  • Infusion and withdrawal. Set a single pumping rate. Set a dispensing volume, or program up to 41 pumping  phases that change pumping rates, set dispensing volumes, insert pauses, control and respond to external signals, sound the buzzer.
  • Create expandable and reconfigurable multi-syringe systems by attaching pumps to each other.

  • FEATURES
  • Infuses and withdraws.
  • Accepts small syringes or large syringes, up to 60 cc.
  • Dispense continuously at a fixed pumping rate as low as 6 µl/hr or as high as 1200 ml/hr.
  • Change pumping rate and direction while pumping.
  • Selectable rate units: µl/hr, µl/mn, ml/hr, ml/mn.
  • Dispense a specified volume.
  • Dispense according to a pumping program to
  • Pre-program dispense volumes. Each volume can be different.
  • Automatically change pumping rates or pumping direction.
  • Ramp up or down the pumping rate.
  • Timed delays between dispenses.
  • Automatically pause the program and wait for the user to continue the dispense.
  • Synchronize dispenses with other equipment or pumps to change pumping rates in reaction to a sensor or signals from other pumps.
  • Send logic signals to other equipment. Change pumping rates in reaction to a sensor.
  • Program the audible alarm to beep at any time to alert the operator.
  • Enter the pumping program from the keypad or download it from a computer.
  • Operates stand-alone, from an RS-232 computer port or from the TTL logic interface.
  • Total volume pumped separately accumulated for infusion and withdrawal.

  • PROGRAMMING FEATURES
  • 41 programmable phases.
  • Set event interrupts from external signals to cause automatic jumps to another part of the program.
  • Conditional jumps based on external inputs.
  • Nested loops: Repeat a section of the program continuously or a set number of times.
  • Program editing functions: Insert and delete program phases.
  • Simplifies program development and updating. Allows quick removal or addition of program phases.
  • Enter programs from the keypad or from a computer.
  • Download or upload pumping programs from or to a computer. Store dispensing programs in a file on your computer, then download them to one or more pumps.
  • Specify in the file to send a different pumping program to each pump in the pump network.
  • Automatically change pumping rates.
  • Insert timed delays between dispenses.
  • The multi-syringe pump has all the programming features of the single syringe pump. There are two options; 6 or 8 syringes.

    CAT. NO. DESCRIPTION